CPI VZX-3530J1

5.0 kW Compact Pulse Amplifier
for Test and Measurement Applications
8 . 0 to 1 2 .0 GHz
The VZX-3530J1
Compact
Global Applications
Eight rack-units tall (14.0 in/356 mm).
230 VAC operation. Designed to meet
International Safety Standard EN61010 and
Electromagnetic Compatibility 2004/108/EC.
Versatile
An integral solid state preamplifier and IEEE
interface are included as standard features.
Easy to Maintain
Modular design and built-in fault diagnostic
capability backed by CPI’s worldwide 24-hour
customer support network that includes sixteen
regional factory service centers.
Communications & Power Industries Canada, Inc.
45 River Drive
Georgetown, Ontario CANADA L7G2J4
tel: +1 (905) 877-0161
fax: +1 (905) 877-5327
e-mail: [email protected]
www.cpii.com/satcom
5.0 kW Compact Pulsed Amplifier
Wide band, automatic fault recycle, user-friendly
microprocessor-controlled logic with integrated
computer interface, digital metering, and quiet
operation suitable for laboratory environments.
8.0 to 12.0 GHz
5000 Watt TWT
Compact Pulsed
Amplifier
8 .0 t o 12. 0 GH z
SPECIFICATIONS, VZX-3530J1
Environmental
Electrical
Frequency
8.0 to 12.0 GHz
Ambient Temperature
Output Peak Power (min.)
TWT
Flange
-10° to +40°C operating
-40° to +70°C non-operating
5000 W
4800 W
Relative Humidity
95% non-condensing
Altitude
10,000 ft. with standard adiabatic
derating of 2°C/1000 ft., operating;
40,000 ft., non-operating
Shock and Vibration
As normally encountered in a
protected laboratory environment
Gain
OPTIONS:
• Remote Control Panel
• Input Isolator
(-1 dB Gain)
65 dB min. at rated power (with no RF options);
67 dB min. at small signal (with no RF options);
deduct one dB of gain from the above
minimums for each RF option
Gain Adjustment Range
20 dB min.
Gain Stability
±0.25 dB/24hr max. (after 30 minute warmup
and at constant drive and temp.)
Input VSWR
2.5:1 typ;
1.5:1 typ. with optional input isolator
Output VSWR
Load VSWR
Cooling (TWT)
Forced air with integral blower
Rear air intake & exhaust;
0.10" water max. external pressure
loss allowable
2.5:1 typ.
RF Input Connection
Type N female
1.5:1 max. for full spec. compliance;
Any value for continuous operation (soft fail
VSWR protection limits at 500 W peak)
RF Output Connection
WR-90 waveguide flange
Dimensions (W x H x D)*
19 x 14 x 27.5 in.
(483 x 356 x 699 mm)
Weight
150 lbs (55 kg) max.
Heat Dissipation
2200 watts max.
Safety
EN61010
Acoustic Noise
65 dBA @ 3 ft. from amplifier
Phase Noise
0.5°rms asynchronous ripple
Pulse Width
0.07 to 50 µs
PRF
50 kHz max, 100 kHz max. available as option
Duty Cycle
6% max.
Delay
400 ns typ.
Droop
0.5 dB over 50 µs
NPO
-10 dBm/MHz Beam On;
-110 dBm/MHz Beam Off
Primary Power
220 - 240 VAC ±10%,
single phase 47- 63 Hz
Power Consumption
2.2 kVA typ.
2.5 kVA max.
Filament Voltage
Reduction of 10% in standby for extended
TWT life (available as option)
Inrush Current
200% max.
Certificate Number: 30515
For more detailed information, please refer to the corresponding CPI Technical Description.
Note: Specifications may change without notice as a result of additional data or product refinement.
Please contact CPI before using this information for system design.
MKT 228, ISSUE 4
01/09
PDF
Mechanical
*Dimensions exclude front handles, rear fans and exhaust ducts.