5.0 kW Compact Pulse Amplifier for Test and Measurement Applications 8 . 0 to 1 2 .0 GHz The VZX-3530J1 Compact Global Applications Eight rack-units tall (14.0 in/356 mm). 230 VAC operation. Designed to meet International Safety Standard EN61010 and Electromagnetic Compatibility 2004/108/EC. Versatile An integral solid state preamplifier and IEEE interface are included as standard features. Easy to Maintain Modular design and built-in fault diagnostic capability backed by CPI’s worldwide 24-hour customer support network that includes sixteen regional factory service centers. Communications & Power Industries Canada, Inc. 45 River Drive Georgetown, Ontario CANADA L7G2J4 tel: +1 (905) 877-0161 fax: +1 (905) 877-5327 e-mail: [email protected] www.cpii.com/satcom 5.0 kW Compact Pulsed Amplifier Wide band, automatic fault recycle, user-friendly microprocessor-controlled logic with integrated computer interface, digital metering, and quiet operation suitable for laboratory environments. 8.0 to 12.0 GHz 5000 Watt TWT Compact Pulsed Amplifier 8 .0 t o 12. 0 GH z SPECIFICATIONS, VZX-3530J1 Environmental Electrical Frequency 8.0 to 12.0 GHz Ambient Temperature Output Peak Power (min.) TWT Flange -10° to +40°C operating -40° to +70°C non-operating 5000 W 4800 W Relative Humidity 95% non-condensing Altitude 10,000 ft. with standard adiabatic derating of 2°C/1000 ft., operating; 40,000 ft., non-operating Shock and Vibration As normally encountered in a protected laboratory environment Gain OPTIONS: • Remote Control Panel • Input Isolator (-1 dB Gain) 65 dB min. at rated power (with no RF options); 67 dB min. at small signal (with no RF options); deduct one dB of gain from the above minimums for each RF option Gain Adjustment Range 20 dB min. Gain Stability ±0.25 dB/24hr max. (after 30 minute warmup and at constant drive and temp.) Input VSWR 2.5:1 typ; 1.5:1 typ. with optional input isolator Output VSWR Load VSWR Cooling (TWT) Forced air with integral blower Rear air intake & exhaust; 0.10" water max. external pressure loss allowable 2.5:1 typ. RF Input Connection Type N female 1.5:1 max. for full spec. compliance; Any value for continuous operation (soft fail VSWR protection limits at 500 W peak) RF Output Connection WR-90 waveguide flange Dimensions (W x H x D)* 19 x 14 x 27.5 in. (483 x 356 x 699 mm) Weight 150 lbs (55 kg) max. Heat Dissipation 2200 watts max. Safety EN61010 Acoustic Noise 65 dBA @ 3 ft. from amplifier Phase Noise 0.5°rms asynchronous ripple Pulse Width 0.07 to 50 µs PRF 50 kHz max, 100 kHz max. available as option Duty Cycle 6% max. Delay 400 ns typ. Droop 0.5 dB over 50 µs NPO -10 dBm/MHz Beam On; -110 dBm/MHz Beam Off Primary Power 220 - 240 VAC ±10%, single phase 47- 63 Hz Power Consumption 2.2 kVA typ. 2.5 kVA max. Filament Voltage Reduction of 10% in standby for extended TWT life (available as option) Inrush Current 200% max. Certificate Number: 30515 For more detailed information, please refer to the corresponding CPI Technical Description. Note: Specifications may change without notice as a result of additional data or product refinement. Please contact CPI before using this information for system design. MKT 228, ISSUE 4 01/09 PDF Mechanical *Dimensions exclude front handles, rear fans and exhaust ducts.