IS15DBFP4RGB Version (1) DISTINCTIVE CHARACTERISTICS • • • • • • • • • • • • High resolution of 64 x 32 pixels 64 colors of backlighting can be controlled dynamically Pushbutton switch with LCD, RGB LED backlighting General brightness of backlight is dynamically controlled in eight steps from dark to bright Operated by commands and data supplied via serial communications (SPI) Can display as many as four lines of text with ten characters each Incorporates bitmap display function Programmable display graphics for alphanumeric characters and animated sequences Dual image VRAM for quick change of displayed images Distinct, long travel of 4.5mm (same as KP01 Series) Low energy consumption Dust tight construction Viewing area: 15.0mm x 10.8mm (horizontal x vertical) High reliability and long life of three million actuations minimum Epoxy sealed straight PC terminals Snap-in standoff for easy, secure mounting and alignment Actual Size www.nkksmartswitch.com • Toll Free 1.877.2BUYNKK • Tel 480.991.0942 • Fax 480.998.1435 • Email: [email protected] SMARTSWITCH TM SWITCH DESCRIPTION Switch Description LCD Mode LED Color LCD/LED SPST Momentary ON Gold Contacts Straight PC Terminals Black & White FSTN Positive Red/Green/Blue SWITCH SPECIFICATIONS Circuit SPST normally open Electrical Capacity (Resistive Load) 100mA @ 12V DC Contact Resistance 200 milliohms maximum @ 20mV 10mA Insulation Resistance 100 megohms minimum @ 100V DC Dielectric Strength 125V AC for 1 minute minimum Mechanical Endurance 3,000,000 operations minimum Electrical Endurance 3,000,000 operations minimum Operating Force 2.0 ± 0.5 Newtons Total Travel 4.5mm (.177”) LCD SPECIFICATIONS Characteristics of Display Display Operation Mode FSTN positive; background colors, black & white Display Condition Transflective with built-in LED backlight Viewing Angle Direction 6 o’clock Viewing Area 15.0mm x 10.8mm (horizontal x vertical) Pixel Format 64 x 32 pixels (horizontal x vertical) Pixel Size 0.20mm x 0.27mm (horizontal x vertical) * Operating Temperature Range –15°C ~ +50°C (+5°F ~ +122°F) Storage Temperature Range –20°C ~ +60°C (–4°F ~ +140°F) Backlight LED RGB: red/green/blue * In a low temperature environment (below 0°C), speed and contrast decrease when image changes. The non-indicator dot may become dense in a high temperature environment (about +50°C). Absolute Maximum Ratings Items Recommended Operating Conditions Symbols Ratings Items Symbols Minimum Typical Maximum 4.9V 5.0V 5.1V Supply Voltage VDD –0.3V to +7.0V Supply Voltage VDD Input Voltage VI –0.3V to VD D +0.3V Input Voltage VI 0V –– VDD Output Voltage VO –0.3V to VD D +0.3V SPI Clock Frequency fSC K –– –– 8MHz Current Consumption I DD ** 10mA –– *** 50mA Optical Characteristics (Temperature at 25°C) Items Symbols Min Typical Max Cr –– 3.0 –– Up & Down q –– 90° –– Right & Left f –– 90° –– Contrast Ratio Viewing Angle (Cr ≥ 1.1) ** 10mA: Backlighting LED is off *** 50mA: Backlighting LEDs (Red, Green, Blue) are maximum brightness www.nkksmartswitch.com • Toll Free 1.877.2BUYNKK • Tel 480.991.0942 • Fax 480.998.1435 • Email: [email protected] SMARTSWITCH TM BLOCK DIAGRAM & PIN CONFIGURATIONS Com1......Com32 Common Driver 32bit Shift Register 64 x 32 Dot Matrix LCD Panel seg1.......seg64 Segment Driver Backlight LED 64bit Shift Register Display Controller High Resolution SMARTSWITCH with RGB LED and Black and White LCD Mode TM NC 9 SS 8 SCK 7 SDI 6 RAM #1 256Byte Red Green Blue RAM #2 256Byte LED Driver SPI SDO 5 VDD 4 GND 3 SW Pin No. Symbol 1 2 3 4 5 6 Name SW SW GND VDD SDO SDI SCK SS NC 7 8 9 2 SW 1 Function Terminal of Switch Terminal of Switch Ground Power Data Out Data In Serial Clock Slave Select None Normally open Normally open Power source for logic circuit and LCD Data output line for SPI Data input line for SPI Clock line for SPI that synchronizes commands and data Chip select for SPI; line is active low No connection TYPICAL SWITCH DIMENSIONS See Pixel Detail Terminal numbers are not on the switch. (15.0) .591 (14.38) .566 (3.9) .154 (18.0) .709 Standoff 1 Standoff 2 (0.6) Typ .024 (20.59) .811 (13.5) .531 (9.42) .371 (10.8) .425 (0.4) Typ .016 See Standoff Detail (16.0) .630 (23.0) .906 (23.13) .911 Pixel Detail (0.27) .010 (0.20) .008 (0.02) Typ .0008 Standoff Detail (1.0) Typ .039 2 (0.2) .008 (16.0) .630 1 Standoff 2 (2.0) Dia .079 Dimension A Standoff 1 = (2.7) Standoff 2 = (2.3) .091 .106 (7.05) .278 (8.0) .315 Footprint (1.25) .049 (2.0) .079 (18.0) .709 (1.0) Typ .039 (6.0) .236 9 3 2x (0.8) (1.0) Dia .031 ~ .039 2 8 4 1 7x (0.8) ~ (1.0) Dia .031 .039 (2.0) .079 (6.0) .236 Standoff 1 (0.3) Typ .012 (3.4) .134 A 9 8 7 6 5 4 3 (7.62) .300 (7.05) .278 (8.0) .315 (7.62) .300 (16.0) .630 4x (1.3) Dia .051 www.nkksmartswitch.com • Toll Free 1.877.2BUYNKK • Tel 480.991.0942 • Fax 480.998.1435 • Email: [email protected] SMARTSWITCH TM TIMING SPECIFICATIONS Circuit Example SPI Characteristics (See Timing Diagram) CLK_1 (Temperature at –15°C ~ +50°C and VDD = 5.0V ± 2%) Items SPI_SS Set Up Time Symbols Minimum ts S S 10ns SPI_SS Hold Time th S S SPI_CLK Cycle tc yc CK SPI_CLK Width thw CK 10ns SPI_DI Set Up Time ts D I 10ns SPI_DI Hold Time th D I 10ns SPI_DO Delay Time td D O 10ns Maximum SCK SDI SS SCK SDI SS SCK SDI IS_1 IS_2 IS_3 SCK SDI SS SCK SDI SS SCK SDI SS IS_4 IS_5 IS_6 SCK SDI SS SCK SDI SS SCK SDI SS SS CLK_2 10ns 8MHz CLK_3 IS_7 DATA_1 SPI Timing Chart (SS Using) IS_8 DATA_2 IS_9 DATA_3 SPI Timing Chart (SS Low Level Fixed) SS th SS t s SS Low SS tcy c CK t cy c CK t h w CK SCK t h DI SDI SCK ts DI t s DI SDI th DI D7 D6 D5 D4 D3 D2 D1 D0 D7 D6 D5 D4 D3 D2 D1 D0 td DO SDO t d DO SDO thw CK D7 D6 D5 D4 D3 D2 D1 D0 D7 D6 D5 D4 D3 D2 D1 D0 SDI and SCK shall be kept high when idle. BITMAP Segment Common COM1 COM2 1 2 3 4 5 6 7 8 9 • • • 16 ••••• 49 • • • 56 57 58 59 60 61 62 63 64 Byte8 Byte7 ••• Byte2 Byte1 D0 D1 D2 D3 D4 D5 D6 D7 D0 • • • D7 ••• D0 • • • D7 D0 D1 D2 D3 D4 D5 D6 D7 Byte16 Byte9 D0 D1 D2 D3 D4 D5 D6 D7 D0 D1 D2 D3 D4 D5 D6 D7 • • • • • • • • • Byte256 COM32 ••• ••• D0 D1 D2 D3 D4 D5 D6 D7 Byte249 D0 D1 D2 D3 D4 D5 D6 D7 Transferring Display Data/Displaying LCD Command and Data Sequence Command Data (256 Bytes) 0 x 55 Byte1 Byte2 • • • Byte255 0 1 0 1 0 1 0 1 D7 D6 D5 D4 D3 D2 D1 D0 D7 D6 • • • D1 D0 Byte256 D7 D6 D5 D4 D3 D2 D1 D0 Notes: Display RAM has two screen areas. The first area is for the display on current LCD; the second area is for the data to be displayed next. The screens are changed when the second area is fully stored. www.nkksmartswitch.com • Toll Free 1.877.2BUYNKK • Tel 480.991.0942 • Fax 480.998.1435 • Email: [email protected] SMARTSWITCH TM COMMANDS & DATA • Transferring display data/displaying on LCD: command (1 Byte) + data (256 Bytes) • Others: command (1 Byte) + data (1 Byte) • Commands can be accepted only when all bits coincide; otherwise, they are not acknowledged • Additional commands will not be received until the communication of commands (1 Byte) and data (256 or 1 Byte) is completed • There is no time limit from the beginning to end of data receipt • Commands may be executed consecutively (no need to wait between commands) • Irregular commands or data are not recognized • Initial status at power activation: LCD display off, LED off (brightness 1/20, color off) Transferring Display Data/Displaying on LCD Command Hex Binary 0 x 55 01010101 Data Remarks 256 Bytes (64 x 32 = 2,048 bits) See below for details of bitmap data Data Remarks LED (Backlight) Color Set Command Hex 0 x 40 Binary 01000000 R R G G B B 1 1 2 bits x 3 For each of RGB: 00 = off 10 = 1/2 01 = 1/4 11 = full LED (Backlight) Brightness Set Command Hex 0 x 41 Data Binary 01000001 *** 1 1 1 1 1 3 bits Remarks For leading 3bits: 100 = 1/3 000 = 1/20 (dark) 101 = 1/2 110 = 2/3 001 = 1/10 111 = full 010 = 1/7 011 = 1/5 (bright) Reset (Returning to Initial Status at Power Activation) Command Hex Binary 0 x 5E 01011110 Data Remarks 00000011 Returning to initial status at power activation www.nkksmartswitch.com • Toll Free 1.877.2BUYNKK • Tel 480.991.0942 • Fax 480.998.1435 • Email: [email protected] SMARTSWITCH TM PRECAUTIONS FOR HANDLING & STORAGE OF LCD DEVICES ATTENTION ELECTROSTATIC SENSITIVE DEVICES Handling 1. The IS Series devices are electrostatic sensitive. 2. Limit operating force to keytop to 100.0N maximum, as excessive pressure may damage the LCD device. 3. The IS series devices are not process sealed. 4. If the LCD is accidentally broken, avoid contact with the liquid and wash off any liquid spills to the skin or clothing. 5. Clean cap surface with dry cloth. If further cleaning is needed, wipe with dampened cloth using neutral cleanser and dry with clean cloth. Do not use organic solvent. 6. Recommended soldering time and temperature limits: 5 seconds maximum @ 270°C maximum 7. Do not exceed 60°C at the LCD level. Storage 1. Store in original container and away from direct sunlight. 2. Keep away from static electricity. 3. Avoid extreme temperatures, high humidity, gaseous substances, and all forms of chemical contamination. www.nkksmartswitch.com • Toll Free 1.877.2BUYNKK • Tel 480.991.0942 • Fax 480.998.1435 • Email: [email protected]