ETC MCEXT9V15WC2

External Power Supply
Features:
•
•
•
•
•
•
Energy star level V
CEC 2008 and EISA 2007 compliant
High efficiency
International safety approvals
Compact dimensions
Class I and II versions
Specifications:
Input:
Input voltage
Input frequency
Inrush current
Earth leakage current
Harmonic currents
No load input power
:
:
:
:
:
:
90 to 264 V ac
47 to 63 Hz
15 A / 30 A for 115 / 230 V ac, cold start
0.75 mA at 240 V ac
Meets EN61000-3-2, class A
<0.5 W
Output:
Output voltage
Minimum load
Total regulation
Maximum ripple and noise
Short circuit protection
Transient response
: See table
: No minimum load required
: See table
: 1% pk-pk, 20 MHz bandwidth
: Trip and restart (hiccup mode), auto recovery
: 2% deviation, recovery to within 1% of nominal in 500 µs for 50% load change
General:
Efficiency
Isolation
:
:
:
:
:
87% typical, energy star level V compliant
3,000 V ac input to output
1,500 V ac input to ground*
500 V dc output to ground*
*Not C8 version
:
:
:
:
0°C to +40°C
-40°C to +85°C
Convection cooled
3,000 m
:
:
:
:
:
:
:
:
EN55022 level B conducted and radiated
EN61000-3-2 class A
EN61000-3-3
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
Environmental:
Operating temperature
Storage temperature
Cooling
Operating altitude
EMC and Safety:
Emissions
Harmonic current
Voltage flicker
ESD immunity
Radiated immunity
EFT/burst
Surge
Conducted immunity
www.element14.com
www.farnell.com
www.newark.com
Page <1>
19/01/12 V1.1
External Power Supply
Specifications:
EMC and Safety:
Magnetic field
Dips and interruptions
Safety approvals
: EN61000-4-8
: EN61000-4-11
: EN60950-1: UL/cUL60950-1, CE mark
Models and Ratings
Maximum Output
Power
12 W
15 W
Output
Voltage(3) (V dc)
Output
Current (A)
Total
Regulation(1)
5
2.4
MCEXT5V15WC2
6
2
MCEXT6V15WC2
7
1.71
MCEXT7V15WC2
9
1.66
12
1.25
15
1
MCEXT15V15WC2
18
0.83
MCEXT18V15WC2
24
0.62
MCEXT24V15WC2
5%
Model
Number(2)
MCEXT9V15WC2
MCEXT12V15WC2
Notes:
1. Total regulation includes line regulation and load regulation
2. Replace x with 1 for Class I and 2 for Class II e.g. MCEXT24V15WC2 for Class II 24 V model
3. The 24 V DC output model meets Energy Star Level IV, all other models meet Energy Star Level V
Mechanical Details
Dimensions : Millimetres (Inches)
www.element14.com
www.farnell.com
www.newark.com
Page <2>
19/01/12 V1.1
External Power Supply
Notes:
1. All dimensions are shown in inches (mm). Tolerance ±0.04 (±1) maximum
2. Output connector : is 0.22 (5.5) outer diameter barrel, 0.10 (2.5) inner diameter barrel with centre positive (+) and outer shell
negative (-). Length is 0.433 (11)
3. Output cable length is 48 inches (1,220 mm) approximately
4. Weight: 0.36 lbs (165 g)
Part Number Table
Description
Part Number
Power Supply, 15 W, Class I, 12 V
MCEXT12V15WC1
Power Supply, 15 W, Class II, 12 V
MCEXT12V15WC2
Power Supply, 15 W, Class I,15 V
MCEXT15V15WC1
Power Supply, 15 W, Class II, 15 V
MCEXT15V15WC2
Power Supply, 15 W, Class I, 5 V
MCEXT5V15WC1
Power Supply, 15 W, Class II, 5 V
MCEXT5V15WC2
Power Supply, 15 W, Class I, 18 V
MCEXT18V15WC1
Power Supply, 15 W, Class II, 18 V
MCEXT18V15WC2
Power Supply, 15 W, Class I, 24 V
MCEXT24V15WC1
Power Supply, 15 W, Class II, 24 V
MCEXT24V15WC2
Power Supply, 15 W, Class I, 6 V
MCEXT6V15WC1
Power Supply, 15 W, Class II, 6 V
MCEXT6V15WC2
Power Supply, 15 W, Class I, 7 V
MCEXT7V15WC1
Power Supply, 15 W, Class II, 7 V
MCEXT7V15WC2
Power Supply, 15 W, Class I, 9 V
MCEXT9V15WC1
Power Supply, 15 W, Class II, 9 V
MCEXT9V15WC2
Disclaimer This data sheet and its contents (the "Information") belong to the Premier Farnell Group (the "Group") or are licensed to it. No licence is granted for the use of it other than for information purposes
in connection with the products to which it relates. No licence of any intellectual property rights is granted. The Information is subject to change without notice and replaces all data sheets previously supplied.
The Information supplied is believed to be accurate but the Group assumes no responsibility for its accuracy or completeness, any error in or omission from it or for any use made of it. Users of this data
sheet should check for themselves the Information and the suitability of the products for their purpose and not make any assumptions based on information included or omitted. Liability for loss or damage
resulting from any reliance on the Information or use of it (including liability resulting from negligence or where the Group was aware of the possibility of such loss or damage arising) is excluded.
This will not operate to limit or restrict the Group's liability for death or personal injury resulting from its negligence. Multicomp is the registered trademark of the Group. © Premier Farnell plc 2012.
www.element14.com
www.farnell.com
www.newark.com
Page <3>
19/01/12 V1.1