MA-COM AHRF600_1

PolySwitch®
PTC Devices
PRODUCT:
Overcurrent Protection Device
308 Constitution Drive
Menlo Park, CA 94025-1164
Phone: 800-227-4856
www.circuitprotection.com
Raychem Circuit Protection Products
AHRF600
DOCUMENT: SCD 25184
PCN: F70668
REV LETTER: B
REV DATE: MAY 8, 2007
PAGE NO.: 1 OF 2
Specification Status: RELEASED
Electrical Rating
Voltage:
16VDC MAX
Insulating Material:
Cured, Flame Retardant Epoxy Polymer
Lead Material:
20 AWG Tin Plated Copper
(0.8 mm [0.032] nom. diameter)
Part Marking:
TABLE I. INSTALLATION ENVELOPE DIMENSIONS:
mm:
in*:
A
B
MIN
MAX
MIN
MAX
-11.2
-21.0
-(0.44)
-(0.83)
*Rounded off approximation
C
MIN
4.3
(0.17)
D
MAX
5.8
(0.23)
MIN
7.6
(0.30)
E
MAX
---
MIN
---
MAX
3.0
(0.12)
F
TYP
1.2
(0.05)
G
MIN
---
MAX
4.19
(0.17)
TABLE II. PERFORMANCE RATINGS:
CURRENT
RATINGS
TIME TO
TRIP
AMPS
SECONDS AT
AT 25°C
25°C, 30 A
HOLD TRIP
MAX
6.0
12.0
6.5
Reference Documents:
Precedence:
Effectivity:
CAUTION:
RESISTANCE
Ra MAX
OHMS
AT 25°C
MIN
MAX
.010
.022
OHMS
AT 25°C
0.032
TRIPPED-STATE
POWER
DISSIPATION
WATTS AT
25°C
TYP
4.1
PS400, PS300
This specification takes precedence over documents referenced herein.
Reference documents shall be the issue in effect on the date of invitation for bid.
Operation beyond the rated voltage or current may result in rupture, electrical arcing or flame.
© 2002 ,2007 Tyco Electronics Corporation. All rights reserved.
PolySwitch®
PTC Devices
308 Constitution Drive
Menlo Park, CA 94025-1164
Phone: 800-227-4856
www.circuitprotection.com
Overcurrent Protection Device
Raychem Circuit Protection Products
PRODUCT:
AHRF600
DOCUMENT: SCD 25184
PCN: F70668
REV LETTER: B
REV DATE: MAY 8, 2007
PAGE NO.: 2 OF 2
TABLE III. AUTOMOTIVE SPECIFIC STRESS TESTS AND TEST CONDITIONS:
ELECTRICAL STRESS TESTS
TEST CONDITIONS (see note 2)
ESD Voltage Withstand
(See note 1)
Short Circuit Fault Current Durability
25kV
Fault Current Durability
350 cycles, 16V/100A
End-of-life Mode Verification
1750 cycles, 16V/100A
Jump Start Endurance
(See note 1)
Load Dump Endurance
(See note 1)
3 cycles, 26V, 1 minute duration
25 cycles, 16V, 200A
10 cycles, 86.5V
Note 1: The PolySwitch devices are tested in series with a load resistance and the voltages specified in the test conditions are
shared between the PolySwitch device and the load resistance as specified in PS400.
Note 2: Please refer to Appendix A of PS400 for the detailed test procedures