PolySwitch® PTC Devices 308 Constitution Drive Menlo Park, CA 94025-1164 Phone: 800-227-4856 www.circuitprotection.com PRODUCT: AHS160 Overcurrent Protection Device Raychem Circuit Protection Products DOCUMENT: SCD 25037 REV LETTER: E REV DATE: JANUARY 9, 2009 PAGE NO.: 1 OF 1 Specification Status: Released Maximum Electrical Rating C Operating Voltage / Interrupt Current 16VDC / 70A Marking: B H G D E F A Notes: 1. All metal surfaces are tin plated. 2. Drawing not to scale. TABLE I. DIMENSIONS: A MIN MAX mm: 8.0 9.4 in*: (0.315) (0.370) B MIN --- C D E F G H MAX MIN MAX MIN MAX MIN MAX MIN MAX MIN MAX MIN 3.0 6.0 6.71 0.56 0.71 0.56 0.71 3.68 3.94 0.66 1.37 0.43 (0.118) (0.24) (0.264) (0.022) (0.028) (0.022) (0.028) (0.145) (0.155) (0.026) (0.054) (0.017) TABLE II. PERFORMANCE RATINGS: CURRENT RATINGS** AMPS AT 0°C HOLD TRIP 1.78 3.56 AMPS AT 20°C HOLD TRIP 1.60 3.20 TIME TO TRIP** AMPS SECONDS AT AT 60°C 20°C, 8.0A HOLD TRIP MAX 1.24 2.48 15 TRIPPED-STATE POWER DISSIPATION** OHMS WATTS AT AT 20°C 20°C MIN MAX* MAX 0.050 0.150 2.2 RESISTANCE VALUES * Maximum resistance is measured 1 hour after reflow. ** Values specified were determined using PCB’s with 0.140” x 2.0 ounce copper traces. Reference Documents: Precedence: Effectivity: CAUTION: PS300, PS400 This specification takes precedence over documents referenced herein. Reference documents shall be the issue in effect on the date of invitation for bid. Operation beyond the rated voltage or current may result in rupture, electrical arcing or flame. Materials Information ROHS Compliant ELV Compliant Pb-Free Halogen Free* HF * Halogen Free refers to: Br≤900ppm, Cl≤900ppm, Br+Cl≤1500ppm © 2006, 2009 Tyco Electronics Corporation. All rights reserved.