RECTRON DB101_11

DB101
THRU
DB107
SINGLE-PHASE GLASS PASSIVATED
SILICON BRIDGE RECTIFIER
VOLTAGE RANGE 50 to 1000 Volts CURRENT 1.0 Ampere
FEATURES
*
*
*
*
*
*
*
*
Good for automation insertion
Surge overload rating - 40 amperes peak
Ideal for printed circuit board
Reliable low cost construction utilizing molded
Glass passivated device
Polarity symbols molded on body
Mounting position: Any
Weight: 1.0 gram
DB-1
MECHANICAL DATA
.255 (6.5)
* Epoxy: Device has UL flammability classification 94V-O
* UL listed under the recognized component directory, file #E94233.
.245 (6.2)
.350 (8.9)
.300 (7.6)
.335 (8.8)
.320 (7.8)
.135 (3.4)
.115 (2.9)
.165 (4.2)
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
.020
(0.5)
Ratings at 25 o C ambient temperature unless otherwise specified.
resistive or inductive load.
.155 (3.9)
.060
(1.5)
.205 (5.2)
.195 (5.0)
Dimensions in inches and (millimeters)
MAXIMUM RATINGS (At T A = 25oC unless otherwise noted)
SYMBOL
DB101
DB102
DB103
DB104
DB105
DB106
DB107
UNITS
Maximum Recurrent Peak Reverse Voltage
RATINGS
VRRM
50
100
200
400
600
800
1000
Volts
Maximum RMS Bridge Input Voltage
VRMS
35
70
140
280
420
560
700
Volts
Maximum DC Blocking Voltage
VDC
50
100
200
400
600
800
1000
Maximum Average Forward Output Current at T A = 40 oC
Volts
IO
1.0
Amps
I FSM
40
Amps
I2t
6.6
A2/Sec
Peak Forward Surge Current 8.3 ms single half sine-wave
superimposed on rated load (JEDEC method)
Current Squarad Time
R qJA
40
RqJL
15
T J, T STG
-55 to + 150
0
Typical Thermal Resistance (Note 2)
Operating and Storage Temperature Range
C/W
0
C
ELECTRICAL CHARACTERISTICS (At TA = 25oC unless otherwise noted)
CHARACTERISTICS
SYMBOL
Maximum Forward Voltage Drop per Bridge
VF
Element at 1.0A DC
Maximum Reverse Current at Rated
@T A = 25 o C
DC Blocking Voltage per element
@T A = 125 o C
IR
Note: 1.”Fully ROHS compliant”,”100% Sn plating(Pb-free).
2. Thermal Resistance: PCB mounted.
3. Available in Halogen-free epoxy by adding suffix -HF after the part nbr.
DB101
DB102
DB103
DB104
DB105
DB106
DB107
UNITS
1.1
Volts
5.0
mAmps
0.5
mAmps
2011-04
REV:B
60
8.3mS Single Half Sine-Wave
JEDEC Method
50
40
30
20
10
0
0
2
4
6
10
20
40
60
100
INSTANTANEOUS FORWARD CURRENT, (A)
PEAK FORWARD SURGE CURRENT, (A)
RATING AND CHARACTERISTICS CURVES ( DB101 THRU DB107 )
10
1
0.1
0.01
T J = 25 OC
Pulse Width = 300mS
1% Duty Cycle
0
1000
FIG. 1 - MAXIMUM NON-REPETITIVE
FORWARD SURGE CURRENT
1.5
TA = 125 OC
100
10
TA = 25 OC
1.0
0
20
40
60
80
100
0.5
1.0
1.5
2.0
2.5
INSTANTANEOUS FORWARD VOLTAGE, (V)
AVERAGE FORWARD CURRENT, (A)
INSTANTANEOUS REVERSE CURRENT, (uA)
NUMBER OF CYCLES AT 60Hz
120
140
PERCENT RATED PEAK REVERSE VOLTAGE, (%)
FIG.3 TYPICAL REVERSE CHARACTERISTICS
FIG.2 TYPICAL INSTANTANEOUS
FORWARD CHARACTERISTICS
1.0
0.5
60 Hz RESISTIVE OR
INDUCTIVE LOAD
0
20
40
60
80
100
120
140 150
AMBIENT TEMPERATURE, (OC)
FIG.4 TYPICAL FORWARD CURRENT
DERATING CURVE
THE MARKING OF DB10X
Marking Description :
Part No.
DB10X
Year Code
Week Code
V Y W W
Marking Description
Part No.
+
DB10X
Rectron Logo
Voltage-code
~ V Y W W~
Year – code
(Y:Last digit of year)
Week – code
(WW:01~52)
1-------50V
2-------100V
3-------200V
4-------400V
5-------600V
6-------800V
7-----1000V
PACKAGING OF DIODE AND BRIDGE RECTIFIERS
TUBE PACK
PACKAGE
PACKING CODE
EA PER BOX
INNER BOX SIZE
CARTON SIZE
EA PER CARTON
WEIGHT(Kg)
DB-1
-C
2,500
450*140*84
464*305*283
15,000
14.30
(mm)
(mm)
DISCLAIMER NOTICE
Rectron Inc reserves the right to make changes without notice to any product
specification herein, to make corrections, modifications, enhancements or other
changes. Rectron Inc or anyone on its behalf assumes no responsibility or liability for any errors or inaccuracies. Data sheet specifications and its information
contained are intended to provide a product description only. "Typical" parameters which may be included on RECTRON data sheets and/ or specifications can and do vary in different applications and actual performance may vary over time. Rectron Inc does not assume any liability arising out of the application or
use of any product or circuit.
Rectron products are not designed, intended or authorized for use in medical,
life-saving implant or other applications intended for life-sustaining or other related applications where a failure or malfunction of component or circuitry may directly or indirectly cause injury or threaten a life without expressed written approval of Rectron Inc. Customers using or selling Rectron components for use in
such applications do so at their own risk and shall agree to fully indemnify Rectron Inc and its subsidiaries harmless against all claims, damages and expenditures.