BR1005 THRU BR1010

BR1005
THRU
BR1010
SINGLE-PHASE SILICON BRIDGE RECTIFIER
VOLTAGE RANGE 50 to 1000 Volts CURRENT 10 Amperes
FEATURES
* Surge overload rating: 200 amperes peak
* Low forward voltage drop
MECHANICAL DATA
*
*
*
*
*
UL listed the recognized component directory, file #E94233
Epoxy: Device has UL flammability classification 94V-O
Lead: Mil-STD-202E method 208C guaranteed
Mounting position: Any
Weight: 7.86 grams
.27±.025
( 6.99±.64 )
.75 (19.1) MIN.
.051 (1.3)
.039 (1.0)
.158 (4.0)
.154 (3.9)
AC
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
o
Ratings at 25 C ambient temperature unless otherwise specified.
AC
Single phase, half wave, 60 Hz, resistive or inductive load.
For capacitive load, derate current by 20%.
.520 (13.21)
.480 (12.19)
.770 (19.558)
.730 (18.542)
.520 (13.21)
.480 (12.19)
Dimensions in inches and (millimeters)
o
MAXIMUM RATINGS (At T A = 25 C unless otherwise noted)
SYMBOL
BR1005
BR101
BR102
BR104
BR106
BR108
Maximum Recurrent Peak Reverse Voltage
VRRM
50
100
200
400
600
800
1000
Volts
Maximum RMS Voltage
VRMS
35
50
70
100
140
200
280
400
420
600
560
800
700
1000
Volts
RATINGS
VDC
Maximum DC Blocking Voltage
Maximum Average Forward Tc = 50 o C
Peak Forward Surge Current 8.3 ms single half sine-wave
superimposed on rated load (JEDEC method)
BR1010 UNITS
Volts
IO
10.0
Amps
I FSM
200
Amps
Current Squarad Time
2
It
166
A2/Sec
Operating Temperature Range
TJ
-55 to + 150
0
C
T STG
-55 to + 150
0
C
Storage Temperature Range
o
ELECTRICAL CHARACTERISTICS (At TA = 25 C unless otherwise noted)
CHARACTERISTICS
SYMBOL
Maximum Forward Voltage Drop per element at 5.0A DC
Maximum Reverse Current at Rated
o
@T A = 25 C
DC Blocking Voltage per element
@T C = 100 oC
VF
IR
NOTES : 1. Thermal Resistance : Mounted on PCB.
2. “Fully ROHS compliant”, “100% Sn plating (Pb-free)”.
3. Available in Halogen-free epoxy by adding suffix -HF after the part nbr.
BR1005
BR101
BR102
BR104
BR106
BR108
BR1010 UNITS
1.1
Volts
5.0
uAmps
0.2
mAmps
2013-11
REV: O
RATING AND CHARACTERISTIC CURVES ( BR1005 THRU BR1010 )
FIG. 2 - TYPICAL FORWARD CURRENT
DERATING CURVE
FIG. 1 - MAXIMUM NON-REPETITIVE FORWARD
250
AVERAGE FORWARD CURRENT, (A)
PEAK FORWARD SURGE CURRENT, (A)
SURGE CURRENT
8.3ms Single Half Sine-Wave
(JEDEC Method)
200
150
100
50
0
1
2
4 6 8 10 20
40 60 80100
NUMBER OF CYCLES AT 60Hz
10
8
SE
6
4
60 Hz RESISTIVE OR
INDUCTIVE LOAD
2
0
0
50
100
CASE TEMPERATURE, (
150
)
FIG. 4- TYPICAL REVERSE CHARACTERISTICS
FIG. 3- TYPICAL INSTANTANEOUS FORWARD
CHARACTERISTICS
100
TJ = 25
Pulse Width = 300us
1% Duty Cycle
10
INSTANTANEOUS REVERSE CURRENT, (uA)
INSTANTANEOUS FORWARD CURRENT, (A)
CA
1.0
.1
10000
1000
O
TA = 125 C
100
10
O
TA = 25 C
1
0
20
40
60
80
100
120
PERCENT OF RATED PEAK REVERSE VOLTAGE, (%)
.01
0
.5
1.0
1.5
2.0
2.5
3.0
3.5
INSTANTANEOUS FORWARD VOLTAGE, (V)
RECTRON
140
RECTRON
Attachment information about BR10X
1.
Internal Circuit
2. Marking on the body
Rectron Logo
Part No.
BR10X
Plant - code
UL Logo
Year – code
(Y: Last digit of year &
A:2010, B:2011……)
Voltage-code
VXXX
05-------50V
1-------100V
Week – code
2-------200V
(WW:01~52)
4-------400V
3. Items marked on the inner box and carton
3.1 On the box (for –B)
CUSTOMER
TYPE
LOT NO.
QUANTITY
Q.A.
DATE
3.2 On the carton
CUSTOMER
TYPE
QUANTITY
LOT NO.
REMARK
6-------600V
8-------800V
10-----1000V
PACKAGING OF DIODE AND BRIDGE RECTIFIERS
BULK PACK
PACKAGE
PACKING CODE
BR-10
-B
EA PER BOX
200
INNER BOX SIZE
(mm)
236*236*50
CARTON SIZE
(mm)
497*251*282
EA PER CARTON
2,000
GROSS
WEIGHT(Kg)
12.24
DISCLAIMER NOTICE
Rectron Inc reserves the right to make changes without notice to any product
specification herein, to make corrections, modifications, enhancements or other
changes. Rectron Inc or anyone on its behalf assumes no responsibility or liability for any errors or inaccuracies. Data sheet specifications and its information
contained are intended to provide a product description only. "Typical" parameters which may be included on RECTRON data sheets and/ or specifications can and do vary in different applications and actual performance may vary over time. Rectron Inc does not assume any liability arising out of the application or
use of any product or circuit.
Rectron products are not designed, intended or authorized for use in medical,
life-saving implant or other applications intended for life-sustaining or other related applications where a failure or malfunction of component or circuitry may directly or indirectly cause injury or threaten a life without expressed written approval of Rectron Inc. Customers using or selling Rectron components for use in
such applications do so at their own risk and shall agree to fully indemnify Rectron Inc and its subsidiaries harmless against all claims, damages and expenditures.