BR1005 THRU BR1010 SINGLE-PHASE SILICON BRIDGE RECTIFIER VOLTAGE RANGE 50 to 1000 Volts CURRENT 10 Amperes FEATURES * Surge overload rating: 200 amperes peak * Low forward voltage drop MECHANICAL DATA * * * * * UL listed the recognized component directory, file #E94233 Epoxy: Device has UL flammability classification 94V-O Lead: Mil-STD-202E method 208C guaranteed Mounting position: Any Weight: 7.86 grams .27±.025 ( 6.99±.64 ) .75 (19.1) MIN. .051 (1.3) .039 (1.0) .158 (4.0) .154 (3.9) AC MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS o Ratings at 25 C ambient temperature unless otherwise specified. AC Single phase, half wave, 60 Hz, resistive or inductive load. For capacitive load, derate current by 20%. .520 (13.21) .480 (12.19) .770 (19.558) .730 (18.542) .520 (13.21) .480 (12.19) Dimensions in inches and (millimeters) o MAXIMUM RATINGS (At T A = 25 C unless otherwise noted) SYMBOL BR1005 BR101 BR102 BR104 BR106 BR108 Maximum Recurrent Peak Reverse Voltage VRRM 50 100 200 400 600 800 1000 Volts Maximum RMS Voltage VRMS 35 50 70 100 140 200 280 400 420 600 560 800 700 1000 Volts RATINGS VDC Maximum DC Blocking Voltage Maximum Average Forward Tc = 50 o C Peak Forward Surge Current 8.3 ms single half sine-wave superimposed on rated load (JEDEC method) BR1010 UNITS Volts IO 10.0 Amps I FSM 200 Amps Current Squarad Time 2 It 166 A2/Sec Operating Temperature Range TJ -55 to + 150 0 C T STG -55 to + 150 0 C Storage Temperature Range o ELECTRICAL CHARACTERISTICS (At TA = 25 C unless otherwise noted) CHARACTERISTICS SYMBOL Maximum Forward Voltage Drop per element at 5.0A DC Maximum Reverse Current at Rated o @T A = 25 C DC Blocking Voltage per element @T C = 100 oC VF IR NOTES : 1. Thermal Resistance : Mounted on PCB. 2. “Fully ROHS compliant”, “100% Sn plating (Pb-free)”. 3. Available in Halogen-free epoxy by adding suffix -HF after the part nbr. BR1005 BR101 BR102 BR104 BR106 BR108 BR1010 UNITS 1.1 Volts 5.0 uAmps 0.2 mAmps 2013-11 REV: O RATING AND CHARACTERISTIC CURVES ( BR1005 THRU BR1010 ) FIG. 2 - TYPICAL FORWARD CURRENT DERATING CURVE FIG. 1 - MAXIMUM NON-REPETITIVE FORWARD 250 AVERAGE FORWARD CURRENT, (A) PEAK FORWARD SURGE CURRENT, (A) SURGE CURRENT 8.3ms Single Half Sine-Wave (JEDEC Method) 200 150 100 50 0 1 2 4 6 8 10 20 40 60 80100 NUMBER OF CYCLES AT 60Hz 10 8 SE 6 4 60 Hz RESISTIVE OR INDUCTIVE LOAD 2 0 0 50 100 CASE TEMPERATURE, ( 150 ) FIG. 4- TYPICAL REVERSE CHARACTERISTICS FIG. 3- TYPICAL INSTANTANEOUS FORWARD CHARACTERISTICS 100 TJ = 25 Pulse Width = 300us 1% Duty Cycle 10 INSTANTANEOUS REVERSE CURRENT, (uA) INSTANTANEOUS FORWARD CURRENT, (A) CA 1.0 .1 10000 1000 O TA = 125 C 100 10 O TA = 25 C 1 0 20 40 60 80 100 120 PERCENT OF RATED PEAK REVERSE VOLTAGE, (%) .01 0 .5 1.0 1.5 2.0 2.5 3.0 3.5 INSTANTANEOUS FORWARD VOLTAGE, (V) RECTRON 140 RECTRON Attachment information about BR10X 1. Internal Circuit 2. Marking on the body Rectron Logo Part No. BR10X Plant - code UL Logo Year – code (Y: Last digit of year & A:2010, B:2011……) Voltage-code VXXX 05-------50V 1-------100V Week – code 2-------200V (WW:01~52) 4-------400V 3. Items marked on the inner box and carton 3.1 On the box (for –B) CUSTOMER TYPE LOT NO. QUANTITY Q.A. DATE 3.2 On the carton CUSTOMER TYPE QUANTITY LOT NO. REMARK 6-------600V 8-------800V 10-----1000V PACKAGING OF DIODE AND BRIDGE RECTIFIERS BULK PACK PACKAGE PACKING CODE BR-10 -B EA PER BOX 200 INNER BOX SIZE (mm) 236*236*50 CARTON SIZE (mm) 497*251*282 EA PER CARTON 2,000 GROSS WEIGHT(Kg) 12.24 DISCLAIMER NOTICE Rectron Inc reserves the right to make changes without notice to any product specification herein, to make corrections, modifications, enhancements or other changes. Rectron Inc or anyone on its behalf assumes no responsibility or liability for any errors or inaccuracies. Data sheet specifications and its information contained are intended to provide a product description only. "Typical" parameters which may be included on RECTRON data sheets and/ or specifications can and do vary in different applications and actual performance may vary over time. Rectron Inc does not assume any liability arising out of the application or use of any product or circuit. Rectron products are not designed, intended or authorized for use in medical, life-saving implant or other applications intended for life-sustaining or other related applications where a failure or malfunction of component or circuitry may directly or indirectly cause injury or threaten a life without expressed written approval of Rectron Inc. Customers using or selling Rectron components for use in such applications do so at their own risk and shall agree to fully indemnify Rectron Inc and its subsidiaries harmless against all claims, damages and expenditures.