DBRF195 Flexible Low Loss 50 Ohm Coaxial Cable that is acceptable substitution for RG-58 & RG-142 And uses standard RG-58 Connectors, used for Jumper assemblies in Wireless Communications Systems, Antenna Feeder Runs and any application requiring a Low Loss RF Cable Description: A. 1/C .037” Gas Injected Foam Polyethylene Insulation, Bonded Aluminum/Polyester/Aluminum Tape, Tinned Copper Braid Shield and Polyethylene Jacket. Construction: 1.0 2.0 3.0 4.0 5.0 Conductor: Insulation: Shield #1: Shield #2: Jacket: 6.0 Marking: .037” Solid Bare Copper; OD: .037 Nom. (0.94mm) .0365” Wall Gas Injected Foamed Polyethylene; OD: .110" Nom. (2.79mm) Aluminum/Polyester/Aluminum –Bonded Tape, 100% Coverage 36 AWG Tinned Copper Braid 90% Coverage .028” Wall Polyethylene; Color: Black OD: .195" Nom. (4.95mm) Surface Printed: GENERAL CABLE (F) DBRF195 -- 50 OHM COAXIAL CABLE - ROHS-- MADE IN USA – MM/YY AAAAAA XXXXXFT MM/YY = month and year of manufacturing AAAAA = MFG identification for Traceability XXXXX = sequential footage marking every two feet B. R E V Electrical characteristics: 1.0 Capacitance: 2.0 Impedance: 3.0 Velocity of Propagation: 4.0 Conductor DCR: 5.0 Shield DCR: DATE 25.4 pF/ft Nom. (83.3 pF/m) 50.0 Ω Nom. 78% Nom. 7.6 Ω/kft Nom. (24.94 Ω/km) 4.89 Ω/kft Nom. (16.04 Ω/km) CHANGE DETAIL General Cable LMR-195 20 Forge Park, Franklin, Ma 02038 Phone: 508-541-7100 Fax: 508-541-8122 Title: F 10/05/12 DBRF195 Revise attn. & added ROHS to legen-gt Description: E 06/15/12 Revise min bend radius / GT D 04/20/12 Edit elec & attn. table / GT C 08/26/11 Chg HHT to GCC an d edit legend / GT Eng Approval: B 9/8/05 Update Spec to New Format - RZ Mktg Approval: A 8/31/04 Spec released - RZ Final Approval: .037” -- 50 Ohm Broadband Indoor/Outdoor Coaxial Cable GT PAGE 1 of 2 General Cable reserves the right to modify this information without prior notification and does not make a warranty or representation of any kind, whether implied or expressed with respect to the information contained herein. General Cable assumes no risks, and will not be liable for direct or indirect, special; incidental or consequential damages, any defect or personal injury resulting from the use of this document. 6.0 7.0 8.0 9.0 10.0 11.0 12.0 C. R E V .064 µH/ft (.21 µH/m) 2.5 kW 1000 VDC 3000 VRMS >90 dB 41 GHz Frequency (MHz) Att. dB/100ft Attn. dB/100m Avg. Power (KW) 30 50 150 220 450 900 1500 1800 2000 2500 3400 5800 1.80 2.34 4.13 5.05 7.39 10.79 14.38 15.95 16.95 19.29 23.12 31.95 5.90 7.68 13.55 16.56 24.24 35.39 47.17 52.32 55.60 63.27 75.83 104.80 0.89 0.68 0.39 0.32 0.22 0.16 0.12 0.11 0.10 0.09 0.08 0.06 Mechanical Characteristics 1.0 2.0 3.0 4.0 5.0 6.0 D. Inductance: Peak Power: Voltage Withstanding: Jacket Spark: Shield Effectiveness: Cutoff Frequency: Attenuation: (Nom.) Cable Weight: Bend Radius (Installation): Bend Radius (Repeated): Tensile Strength: Operating Temperature: Storage Temperature: Compliance: DATE 21.0 lbs./kft / (31.25 Kg/km) 0.5 inch / (12.7 mm) min 2.0 inch / (50.8 mm) min 40 Lbs. / (178.0 N) -40°C to +80°C -70°C to +85°C RoHS Compliant CHANGE DETAIL General Cable LMR-195 20 Forge Park, Franklin, Ma 02038 Phone: 508-541-7100 Fax: 508-541-8122 Title: F 10/05/12 DBRF195 Revise attn. & added ROHS to legen-gt Description: E 06/15/12 Revise min bend radius / GT D 04/20/12 Edit elec & attn. table / GT C 08/26/11 Chg HHT to GCC an d edit legend / GT Eng Approval: B 9/8/05 Update Spec to New Format - RZ Mktg Approval: A 8/31/04 Spec released - RZ Final Approval: .037” -- 50 Ohm Broadband Indoor/Outdoor Coaxial Cable GT PAGE 2 of 2 General Cable reserves the right to modify this information without prior notification and does not make a warranty or representation of any kind, whether implied or expressed with respect to the information contained herein. General Cable assumes no risks, and will not be liable for direct or indirect, special; incidental or consequential damages, any defect or personal injury resulting from the use of this document.