AIMTEC AM2LP

Series AM2LP-NZ
2 Watt | DC-DC Converter
FEATURES:








SMD Package
Single Output Models
Low Ripple and Noise
High efficiency up to 81%
Operating temperature -40oC to + 85oC
Input / Output Isolation 1000 VDC
Pin compatible with multiple manufacturers
RoHS compliant
Models
Single output
Model
Input Voltage
(V)
Output Voltage
(V)
Output Current
max (mA)
Isolation
(VDC)
Efficiency
(%)
4.5-5.5
4.5-5.5
4.5-5.5
10.8-13.2
10.8-13.2
10.8-13.2
21.6-26.4
21.6-26.4
21.6-26.4
21.6-26.4
5
12
15
5
12
15
5
12
15
24
400
167
133
400
167
133
400
167
133
84
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
78
79
80
78
80
81
78
80
81
80
AM2LP-0505S-NZ
AM2LP-0512S-NZ
AM2LP-0515S-NZ
AM2LP-1205S-NZ
AM2LP-1212S-NZ
AM2LP-1215S-NZ
AM2LP-2405S-NZ
AM2LP-2412S-NZ
AM2LP-2415S-NZ
AM2LP-2424S-NZ
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
Input Specifications
Parameters
Voltage range
Nominal
Typical
5
12
24
Maximum
4.5-5.5
10.8-13.2
21.6-26.4
Capacitor
Filter
Units
VDC
Isolation Specifications
Parameters
Tested I/O voltage
Resistance
Conditions
Typical
60 sec
500Vdc
>1000
Conditions
Typical
Rated
Units
1000
VDC
MOhm
Maximum
Units
Output Specifications
Parameters
Voltage accuracy
Short Circuit protection
Line voltage regulation
Load voltage regulation
Temperature coefficient
Ripple & Noise
Minimum Load Current
See the tolerance graph
±5
Momentary (1sec)
1.2
10
±0.03
150
10
For 1.0% of Vin
Load 10 – 100%
20MHz Bandwidth
%
% of Vin
%
%/oC
mV p-p
% of Max
If the operating output current is less than 10% of maximum it is recommended to install a load resistor in parallel with the
load to ensure the actual load current meets the minimum load current requirement.
General Specifications
Parameters
Switching frequency
Operating temperature
Storage temperature
Maximum case temperature
Cooling
www.aimtec.com
F 051e R12.A
Conditions
Typical
100% load
Without derating
500
Maximum
Units
+95
KHz
o
C
o
C
o
C
-40 to +85
-55 to +125
Free air convection
Tel: +1 514 620 2722
1 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM2LP-NZ
2 Watt | DC-DC Converter
General Specifications (continued)
Parameters
Humidity
Case material
Weight
Dimensions (L x W x H)
MTBF
Maximum soldering temperature
Conditions
Single
1
2
3
4
5
6
7
8
- V Input
+ V Input
N. C.
- V Output
.+V Output
N.C.
N.C.
N.C.
Maximum
Units
95
% RH
Plastic UL94-VO
1.41
0.50 x 0.30 x 0.24 inches
12.70 x 11.20 x 6.50 mm
> 3,500,000 hours (MIL-HDBK -217F, Ground Benign, t=+25oC)
1.5mm from case for 10 sec
260
Pin Out Specifications
Pin
Typical
Dimensions
o
C
Front View
6.70
(0.26)
Side View
4.13
(0.16)
A
6.00 6.25
(0.24) (0.25)
0.30
(0.01)
0.25
(0.01)
1.85
(0.07)
Top View
N.C: Not Connected
g
7.00
(0.28)
A
12.70
(0.50)
0.50
(0.02)
11.20 7.50
(0.44) (0.30)
5.00º angle
1
1.50
(0.06)
0.60
(0.024)
2.54
(0.10)
All dimensions are in mm (inch)
All Pins are on a 2.54mm (0.10inch) pitch
with tolerance of ±0.25mm (0.01inch)
Tolerance Graph
+10%
Recommended Filter Circuit
Typical Load Line
+ Vin
+5%
Nominal
Voltage
-2.5%
+
Cin +
DC
-7.5%
50%
Output Current(%)
DC
Cout
- Vin
- Vin
www.aimtec.com
F 051e R12.A
+Vout
+2.5%
Output Voltage
10%
L
Single Output
L
100%
Tel: +1 514 620 2722
2 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM2LP-NZ
2 Watt | DC-DC Converter

If it is required to decrease the input/output ripple, an “LC” filter network can be installed on the input and output of the
converter (see above).

It should be noted that the inductance and the resonant frequency of the “LC” filtering network should differ from the
DC/DC converter switching frequency to avoid mutual interference.

The capacitance of the output filter capacitor must not exceed the values in the Table below to avoid startup problems
and ensure safe and reliable operation.

It’s not recommended to connect any external capacitor in the application field when output loading is less than 0.5 watt.
External Capacitor Tables
Input Capacitor (Cin)
Vin
Cin
(VDC)
(uF)
5
12
24
4.7
2.2
0.47
Output Capacitor (Cout)
Single Vout
Cout
(VDC)
(uF)
5
12
15
24
10
2.2
1
0.47
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 051e R12.A
Tel: +1 514 620 2722
3 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only