AIMTEC AM2N-NZ

Series AM2N-NZ
2 Watt | DC-DC Converter
FEATURES:
•
•
•
•
•
•
•
RoHS compliant
24 Pin DIP Package
Low profile plastic package
High efficiency up to 82%
Operating temperature -40oC to + 85oC
Input / Output Isolation 6000VDC
Pin compatible with multiple manufacturers
Models
Single output
Model
AM2N-0505SH60-NZ
AM2N-0509SH60-NZ
AM2N-0512SH60-NZ
AM2N-0515SH60-NZ
AM2N-1205SH60-NZ
AM2N-1209SH60-NZ
AM2N-1212SH60-NZ
AM2N-1215SH60-NZ
Input Voltage
(V)
Output Voltage
(V)
Output Current
max (mA)
Isolation
(VDC)
Efficiency
(%)
5
9
12
15
5
9
12
15
400
222
167
133
400
222
167
133
6000
6000
6000
6000
6000
6000
6000
6000
78
79
80
80
79
80
82
82
4.5-5.5
4.5-5.5
4.5-5.5
4.5-5.5
10.8-13.2
10.8-13.2
10.8-13.2
10.8-13.2
Models
Dual output
Model
AM2N-0505DH60-NZ
AM2N-0509DH60-NZ
AM2N-0512DH60-NZ
AM2N-0515DH60-NZ
AM2N-1205DH60-NZ
AM2N-1209DH60-NZ
AM2N-1212DH60-NZ
AM2N-1215DH60-NZ
Input Voltage
(V)
Output Voltage
(V)
4.5-5.5
4.5-5.5
4.5-5.5
4.5-5.5
10.8-13.2
10.8-13.2
10.8-13.2
10.8-13.2
±5
±9
±12
±15
±5
±9
±12
±15
Output Current
max (mA)
Isolation
(VDC)
Efficiency
(%)
6000
6000
6000
6000
6000
6000
6000
6000
78
79
80
80
79
80
82
82
±200
±110
±84
±67
±200
±110
±84
±67
Input Specifications
Parameters
Voltage range
Nominal
Typical
5
12
4.5-5.5
10.8-13.2
Filter
Maximum
Units
VDC
Capacitor
Isolation Specifications
Parameters
Tested I/O voltage
Resistance
Conditions
Typical
60 sec
Rated
Units
6000
VDC
MOhm
>1000
Output Specifications
Parameters
Voltage accuracy
Short Circuit protection
Line voltage regulation (Single)
Line voltage regulation (Dual)
Load voltage regulation (Single)
Load voltage regulation (Dual)
Temperature coefficient
Ripple & Noise
www.aimtec.com
F 051e R6.D
Conditions
Typical
For 1.0% of Vin
For 1.0% of Vin
Load 10-100%
Load 10-100%
At 20MHz Bandwidth
Maximum
See tolerance graph
Momentary (1 sec)
±1.2
±1.2
15
15
±0.03
100
Tel: +1 514 620 2722
1 of 3
Units
%
%
%
%
%/oC
mV p-p
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM2N-NZ
2 Watt | DC-DC Converter
General Specifications
Parameters
Switching frequency
Operating temperature
Storage temperature
Max Case temperature
Cooling
Humidity
Case material
Weight
Dimensions (L x W x H)
MTBF
Conditions
Typical
100% load
Without derating
35
Maximum
Units
95
KHz
o
C
o
C
o
C
90
%
-40 to +85
-55 to +125
Free air convection
Plastic UL94-VO
16
g
1.27 x 0.58 x 0.37 inches 32.30 x 14.70 x 9.40 mm
>1 000 000 hrs (MIL-HDBK -217F, Ground Benign, t=+25oC)
NOTE: All specifications are in this datasheet measured at an ambient temperature of 25°C, humidity<75%, nominal input
voltage and at rated output load unless otherwise specified.
Safety Specifications
Parameters
Agency approvals
Standards
cULus
UL60950-1
Pin Out Specifications
Pin
Dimensions
Single
1
2
8,17
10,15
12,13
Dual
32.30
(1.27)
Top
View
+V Input
+V Input
-V Input
-V Input
N.C.
-V Output
-V Output
Common
+V Output
+V Output
All other pins No Connection
14.70
(0.58)
Footprint
2.54
(0.10)
1.00 0 + 0.15/-0
2.54
(0.01)
Side
View
9.40
(0.37)
0.65
(0.03)
4.00
(0.16)
2.54
(0.10)
27.94
(1.10)
Typical characteristics
Tolerance Envelope Graph
+10%
Typic
a
+5%
line
+2.5%
-2.5%
Output Voltage (%)
Nominal
Voltage
l load
-7.5%
10%
50%
100%
Output Current (%)
www.aimtec.com
F 051e R6.D
Tel: +1 514 620 2722
2 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM2N-NZ
2 Watt | DC-DC Converter
Filtering single output
Filtering dual output
External capacitor – Single output
External capacitor – Dual output
Vin
(VDC)
External
capacitor
(uF)
Vout
(VDC)
External
capacitor
(uF)
Vin
(VDC)
External
capacitor
(uF)
5
12
24
-
4.7
2.2
1
-
5
9
12
15
10
4.7
2.2
1
5
12
24
-
4.7
2.2
1
-
Vout
(VDC)
5
9
12
15
External
capacitor
(uF)
4.7
2.2
1
0.47
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 051e R6.D
Tel: +1 514 620 2722
3 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only