TDK JWS150

NEMIC-LAMBDA
JWS 150
SPECIFICATIONS
A160-01-01A
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28 Isolation Resistance
29 Vibration
30 Shock (In package)
31 Safety
32
33
34
35
JWS150
JWS150
JWS150
JWS150
JWS150
-5
-12
-15
-24
-48
5
12
15
24
48
30
13
10
6.5
3.3
150
156
150
156
158.4
75
77
78
80
80
85 ~ 265VAC (47 ~ 63Hz) or 120 ~ 330VDC
1.5/0.75
2.0/1.0
25A at 100VAC, 50A at 200VAC, Ta=25°C, Cold Start
Built to meet EN61000-3-2
0.99/0.95
2.85~3.63 4.5~5.5
10.8~13.2 13.5~16.5 21.6~26.4 43.2~52.8
120
120
150
150
150
200
160
160
180
180
180
240
20
20
48
60
96
192
40
40
96
120
150
240
Less than 0.02%/°C
31.5 ~
31.5 ~
13.65 ~
10.5 ~
6.82 ~
3.46 ~
3.79~4.95 5.75~6.75 13.8~16.2 17.3~20.3 27.6~32.4 55.2~64.8
20ms
0.75mA MAX, 0.2mA(Typ) at 100VAC / 0.44mA(Typ) at 230VAC
Possible
Possible
-10 ~+60°C ( -10 ~+50°C:100%, +60°C:60%)
30 ~ 90%RH (No dewdrop)
-30 ~ +85°C
10 ~ 95%RH (No dewdrop)
Convection Cooling
Input - FG : 2kVAC (20mA), Input - Output : 3kVAC (20mA)
Output - FG : 500VAC (100mA) for 1min
More than 100MΩ at 25°C and 70%RH Output - FG ... 500VDC
At no operating, 10 ~ 55Hz (Sweep for 1min)
2
19.6m/s Constant, X,Y,Z 1hour each.
2
Less than 196.1m/s
Approved by UL1950, CSA950, EN60950,VDE0160.
(*11) Built to meet DENTORI.
Built to meet EN55011/EN55022-B, FCC-ClassB, VCCI-B.
Built to meet EN55011/EN55022-B, FCC-ClassB, VCCI-B.
850
g
65
x
92
x
198
(
Refer
to Outline Drawing )
mm
MODEL
ITEMS
Nominal Output Voltage
V
Maximum Output Current
A
Maximum Output Power
W
Efficiency (Typ)
(*1) %
Input Voltage Range
(*2) Input Current (100/200VAC)(Typ) (*1) A
Inrush Current(Typ)
PFHC
Power Factor (100/200VAC)(Typ) (*1) Output Voltage Range
V
Maximum Ripple & Noise 0 ~ +60°C mV
(*3) -10 ~ 0°C mV
Maximum Line Regulation
(*4) mV
Maximum Load Regulation
(*5) mV
Temperature Coefficient
Over Current Protection
(*6) A
Over Voltage Protection
(*7) V
Hold-up Time (Typ)
(*8) Leakage Current
(*9) Remote Sensing
Parallel Operation
Series Operation
Operating Temperature
(*10) Operating Humidity
Storage Temperature
Storage Humidity
Cooling
Withstand Voltage
-
Conducted Emission
Radiated Emission
Weight(Typ.)
Size (W x H x D)
JWS150
-3
3.3
30
99
67
*Read instruction manual carefully, before using the power supply unit.
=NOTES=
*1. At 100/200VAC, Ta=25°C and maximum output power.
*2. For cases where conformance to various safety specs (UL, CSA, EN) are required,
input voltage range will be 100 ~ 240VAC(50/60Hz).
*3. Measure with EIAJ RC-9131 probe, Bandwise of scope :100MHz.
*4. 85 ~ 265VAC , constant load.
*5. No load-Full load, constant input voltage.
*6. Constant current limit with automatic recovery.
*7. OVP circuit will shut down output, manual reset (Line recycle).
*8. At 100/200VAC nominal output voltage and maximum output current.
*9. Measured by the each measuring method of UL,CSA,EN and DENTORI(at 60Hz).
*10. Ratings - Derating at standard mounting.
- Load (%) is percent of maximum output power or maximum output current, whichever is greater.
- As for other mountings, refer to derating curve (A160-01-02_).
NEMIC-LAMBDA
JWS 150
OUTPUT DERATING
A160-01-02
Ta(°C)
-10 ~+40
45
50
55
60
MOUNTING A
100
100
100
80
60
LOAD(%)
MOUNTING B
100
80
60
-
MOUNTING C
100
80
60
-
OUTPUT DERATING CURVE
100
LOAD(%)
80
MOUNTING A
MOUNTING B,C
60
40
20
0
-10
0
10
20
30
40
50
60
Ta(°C)
MOUNTING A
(STANDARD MOUNTING)
MOUNTING B
MOUNTING C
DON'T USE
DON'T USE