ETC PH100F24-2

NEMIC-LAMBDA
PH100F24
SPECIFICATION
C101-01-01A
MODEL
PH100F PH100F
ITEMS
24-2
24-3
PH100F
PH100F PH100F PH100F PH100F
24-5
24-12
24-15
24-24
24-48
1 Nominal Output Voltage
V
2
3
5
12
15
24
28
2 Maximum Output Current
A
20
20
20
8.4
6.7
4.2
3.6
3 Nominal Output Power
4 Efficiency (Typ.)
(*1)
W
40
60
100
100.8
100.5
100.8
100.8
%
66
70
80
81
82
83
83
5.11
5.06
5.06
5 Input Voltage Range
6 Input Current (Typ.)
7 Output Voltage Accuracy
(*1)
A
18 ~ 36VDC
2.53
3.57
5.21
5.19
±1%
(*1)
-
(*10)
-
9 Maximum Ripple & Noise
(*9)
mV
100
100
100
150
150
240
280
10 Maximum Line Regulation
(*2)
mV
20
20
20
48
60
96
112
11 Maximum Load Regulation
(*3)
mV
40
40
40
96
120
192
224
12 Over Current Protection
(*4)
A
13 Over Voltage Protection
(*5)
V
8 Output Voltage Range
±20%
+20%, -60%
105% ~ 140%
165% ~ 240%
125% ~ 145%
14 Remote Sensing
(*8)
-
Possible
15 Remote ON/OFF Control
(*8)
-
Possible (SHORT:ON OPEN:OFF)
16 Parallel Operation
(*8)
-
Possible
17 Series Operation
(*8)
-
Possible
18 I.O.G. Signal
(*8)
-
Possible (Open Collector Output)
19 Operating Temperature
(*6)
-
- 20°C ~ + 85°C (Base plate) Ambient Temperature MIN = - 20°C.
20 Operating Humidity
-
30 - 95%RH (No Dewdrop)
21 Storage Temperature
-
- 40°C ~ + 85°C
22 Storage Humidity
-
10 - 95%RH (No Dewdrop)
-
Conduction Cooled
23 Cooling
(*7)
24 Temperature Coefficient (%)
-
0.02% / °C
25 Withstand Voltage
-
Input-Baseplate : 2kVAC, Input-Output : 2kVAC(20mA) for 1min
26 Isolation Resistance
27 Vibration
-
Output-Baseplate : 500VDC(100mA) for 1min
-
More than 100Mohm at 25°C and 70%RH Output-Baseplate...500VDC
-
At No Operating, 10-55Hz (Sweep for 1min)
Amplitude 0.825mm Constant (Maximum 49.0m/s2) X,Y,Z 1h each
28 Shock
-
196.1m/s2 (In package)
29 Weight (Typ.)
-
180g
mm
83 x 12.7 x 86 (Refer to Outline Drawing)
30 Size (W x H x D)
=NOTES=
*DERATING CURVE*
*1. At 24VDC and Maximum Output Current.
*2. 18 ~ 36VDC, Constant Load.
100
*3. No load ~ Full load, Constant input voltage.
*4. Constant current limiting with automatic recovery.
80
*6. Ratings - Refer to Derating Curve on the Right.
- Load(%) is Percent of Maximum Output
Current.
*7. Heatsink has to be Chosen According to Instruction
Manual.
Load (%)
*5. Inverter shutdown method, Manual Reset.
60
40
20
*8. Refer to Instruction Manual.
*9 External Components are Needed for Operation.
(Refer to Basical Connection and Instruction Manual)
*10 At 24VDC Input.(Refer to Instruction Manual.)
0
-20
0
20
40
60
Baseplate (°C)
80
85 100