NEMIC-LAMBDA PH100F24 SPECIFICATION C101-01-01A MODEL PH100F PH100F ITEMS 24-2 24-3 PH100F PH100F PH100F PH100F PH100F 24-5 24-12 24-15 24-24 24-48 1 Nominal Output Voltage V 2 3 5 12 15 24 28 2 Maximum Output Current A 20 20 20 8.4 6.7 4.2 3.6 3 Nominal Output Power 4 Efficiency (Typ.) (*1) W 40 60 100 100.8 100.5 100.8 100.8 % 66 70 80 81 82 83 83 5.11 5.06 5.06 5 Input Voltage Range 6 Input Current (Typ.) 7 Output Voltage Accuracy (*1) A 18 ~ 36VDC 2.53 3.57 5.21 5.19 ±1% (*1) - (*10) - 9 Maximum Ripple & Noise (*9) mV 100 100 100 150 150 240 280 10 Maximum Line Regulation (*2) mV 20 20 20 48 60 96 112 11 Maximum Load Regulation (*3) mV 40 40 40 96 120 192 224 12 Over Current Protection (*4) A 13 Over Voltage Protection (*5) V 8 Output Voltage Range ±20% +20%, -60% 105% ~ 140% 165% ~ 240% 125% ~ 145% 14 Remote Sensing (*8) - Possible 15 Remote ON/OFF Control (*8) - Possible (SHORT:ON OPEN:OFF) 16 Parallel Operation (*8) - Possible 17 Series Operation (*8) - Possible 18 I.O.G. Signal (*8) - Possible (Open Collector Output) 19 Operating Temperature (*6) - - 20°C ~ + 85°C (Base plate) Ambient Temperature MIN = - 20°C. 20 Operating Humidity - 30 - 95%RH (No Dewdrop) 21 Storage Temperature - - 40°C ~ + 85°C 22 Storage Humidity - 10 - 95%RH (No Dewdrop) - Conduction Cooled 23 Cooling (*7) 24 Temperature Coefficient (%) - 0.02% / °C 25 Withstand Voltage - Input-Baseplate : 2kVAC, Input-Output : 2kVAC(20mA) for 1min 26 Isolation Resistance 27 Vibration - Output-Baseplate : 500VDC(100mA) for 1min - More than 100Mohm at 25°C and 70%RH Output-Baseplate...500VDC - At No Operating, 10-55Hz (Sweep for 1min) Amplitude 0.825mm Constant (Maximum 49.0m/s2) X,Y,Z 1h each 28 Shock - 196.1m/s2 (In package) 29 Weight (Typ.) - 180g mm 83 x 12.7 x 86 (Refer to Outline Drawing) 30 Size (W x H x D) =NOTES= *DERATING CURVE* *1. At 24VDC and Maximum Output Current. *2. 18 ~ 36VDC, Constant Load. 100 *3. No load ~ Full load, Constant input voltage. *4. Constant current limiting with automatic recovery. 80 *6. Ratings - Refer to Derating Curve on the Right. - Load(%) is Percent of Maximum Output Current. *7. Heatsink has to be Chosen According to Instruction Manual. Load (%) *5. Inverter shutdown method, Manual Reset. 60 40 20 *8. Refer to Instruction Manual. *9 External Components are Needed for Operation. (Refer to Basical Connection and Instruction Manual) *10 At 24VDC Input.(Refer to Instruction Manual.) 0 -20 0 20 40 60 Baseplate (°C) 80 85 100