TDK JW-50

NEMIC-LAMBDA
JWS 50
SPECIFICATIONS
A157-01-01A
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
MODEL
JWS50
JWS50
JWS50
JWS50
JWS50
JWS50
ITEMS
-3
-5
-12
-15
-24
-48
Nominal Output Voltage
V
3.3
5
12
15
24
48
Maximum Output Current
A
10
10
4.3
3.5
2.2
1.1
Maximum Output Power
W
33
50
51.6
52.5
52.8
52.8
Efficiency (Typ)
(*1) %
65
74
76
77
79
79
Input Voltage Range
(*2) 85 - 265VAC (47-63Hz) or 120 - 330VDC
Input Current (100/200VAC)(Typ) (*1) A
0.6/0.3
0.8/0.4
Inrush Current(Typ)
14A at 100VAC, 28A at 200VAC, Ta=25°C, Cold Start
PFHC
Built to meet EN61000-3-2
Power Factor (100/200VAC)(Typ) (*1) 0.99/0.95
Output Voltage Range
V 2.85-3.63
4.5-5.5
10.8-13.2 13.5-16.5 21.6-26.4 43.2-52.8
Maximum Ripple & Noise 0 ~ +60°C mV
120
120
150
150
150
200
(*3) -10 ~ 0°C mV
160
160
180
180
180
240
Maximum Line Regulation
(*4) mV
20
20
48
60
96
192
Maximum Load Regulation
(*5) mV
40
40
96
120
150
240
Temperature Coefficient
Less than 0.02%/°C
Over Current Protection
(*6) A
10.5 ~
10.5 ~
4.5 ~
3.6 ~
2.3 ~
1.15 ~
Over Voltage Protection
(*7) - 3.79-4.95 5.75-6.75 13.8-16.2 17.3-20.3 27.6-32.4 55.2-64.8
Hold-up Time (Typ)
(*8) 20ms
Leakage Current
(*9) 0.75mA MAX, 0.2mA(Typ) at 100VAC / 0.44mA(Typ) at 230VAC
Remote Sensing
Parallel Operation
Series Operation
Possible
Operating Temperature
(*10) -10 ~+60°C ( -10 ~+50°C:100%,+60°C:60%)
Operating Humidity
30 ~ 90%RH (No dewdrop)
Storage Temperature
-30 ~ +85°C
Storage Humidity
10 ~ 95%RH (No dewdrop)
Cooling
Convection Cooling
Withstand Voltage
Input - FG : 2KVAC (20mA), Input - Output : 3KVAC (20mA)
Output - FG : 500VAC (100mA) for 1min
Isolation Resistance
More than 100Mohm at 25°C and 70%RH Output - FG... 500VDC
Vibration
At no operating, 10-55Hz (Sweep for 1min)
19.6m/s2 Constant, X,Y,Z 1hour each.
2
Shock (In package)
Less than 196.1m/s
Safety
(*11) Approved by UL1950, CSA950, EN60950,VDE0160.
Built to meet DENTORI
Conducted Emission
Built to meet EN55011/EN55022-B, FCC-ClassB, VCCI-B.
Radiated Emission
Built to meet EN55011/EN55022-B, FCC-ClassB, VCCI-B.
Weight(Typ.)
g
350
Size (WxHxD)
mm
37 x 85 x 159 ( Refer to Outline Drawing )
*Read instruction manual carefully, before using the power supply unit.
=NOTES=
*1. At 100/200VAC, Ta=25°C and maximum output power.
*2. For cases where conformance to various safety specs (UL, CSA, EN) are required,
input voltage range will be 100-240VAC(50/60Hz).
*3. Measure with EIAJ RC-9131 probe, Bandwise of scope :100MHz.
*4. 85 - 265VAC , constant load.
*5. No load-Full load, constant input voltage.
*6. Constant current limit with automatic recovery.
*7. OVP circuit will shut down output, manual reset (Line recycle).
*8. At 100/200VAC nominal output voltage and maximum output current.
*9. Measured by the each measuring method of UL,CSA,EN and DENTORI(at 60Hz).
*10. Ratings - Derating at standard mounting.
- Load (%) is percent of maximum output power or maximum output current, whichever is greater.
- As for other mountings, refer to derating curve (A157-01-02_).
*11. As for DENTORI, built to meet at 100VAC.
NEMIC-LAMBDA
JWS 50
OUTPUT DERATING
A157-01-02
Ta(°C)
-10 ~+40
45
50
55
60
MOUNTING A
100
100
100
80
60
LOAD(%)
MOUNTING B
MOUNTING C
100
100
100
100
80
80
60
60
-
MOUTING D
100
80
60
-
OUTPUT DERATING CURVE
120
LOAD(%)
100
80
MOUNTING A
MOUNTING B,C
MOUNTING D
60
40
20
0
-10
0
10
20
30
40
50
60
70
Ta(°C)
MOUNTING A
(STANDARD MOUNTING)
MOUNTING B
MOUNTING C
MOUNTING D
DON'T USE
NEMIC-LAMBDA
JWS 50
SPECIFICATIONS
A157-01-03B
MODEL
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
ITEMS
Nominal Output Voltage
V
Maximum Output Current
A
Maximum Output Power
W
Efficiency (Typ)
(*1) %
Input Voltage Range
(*2) Input Current (100/200VAC)(Typ) (*1) A
Inrush Current(Typ)
PFHC
Power Factor (100/200VAC)(Typ) (*1) Output Voltage Range
V
Maximum Ripple & Noise 0 ~ +60°C mV
(*3) -10 ~ 0°C mV
Maximum Line Regulation
(*4) mV
Maximum Load Regulation
(*5) mV
Temperature Coefficient
Over Current Protection
(*6) A
Over Voltage Protection
(*7) Hold-up Time (Typ)
(*8) Leakage Current
(*9) Remote Sensing
Parallel Operation
Series Operation
Operating Temperature
(*10) Operating Humidity
Storage Temperature
Storage Humidity
Cooling
Withstand Voltage
-
28 Isolation Resistance
29 Vibration
-
30 Shock (In package)
31 Safety
(*11) -
32
33
34
35
Conducted Emission
Radiated Emission
Weight(Typ.)
Size (WxHxD)
g
mm
JWS50
JWS50
-9
-28
9
28
5.6
2.0
50.4
56.0
74
79
85 - 265VAC (47-63Hz) or 120 - 330VDC
0.8/0.4
14A at 100VAC, 28A at 200VAC, Ta=25°C, Cold Start
Built to meet EN61000-3-2
0.99/0.95
8.1-9.9
25.2-30.8
150
150
180
180
36
112
76
160
Less than 0.02%/°C
5.88 ~
2.10 ~
10.4-12.2
32.2-37.8
20ms
0.75mA MAX, 0.2mA(Typ) at 100VAC / 0.44mA(Typ) at 230VAC
Possible
-10 ~+60°C ( -10 ~+50°C:100%,+60°C:60%)
30 ~ 90%RH (No dewdrop)
-30 ~ +85°C
10 ~ 95%RH (No dewdrop)
Convection Cooling
Input - FG : 2kVAC (20mA), Input - Output : 3kVAC (20mA)
Output - FG : 500VAC (100mA) for 1min
More than 100Mohm at 25°Cand 70%RH Output - FG...500VDC
At no operating, 10-55Hz (Sweep for 1min)
19.6m/s2 Constant, X,Y,Z 1hour each.
Less than 196.1m/s2
Approved by UL1950, CSA950, EN60950,VDE0160.
Built to meet DENTORI
Built to meet EN55011/EN55022-B, FCC-ClassB, VCCI-B.
Built to meet EN55011/EN55022-B, FCC-ClassB, VCCI-B.
350
37 x 85 x 159 ( Refer to Outline Drawing )
*Read instruction manual carefully, before using the power supply unit.
=NOTES=
*1. At 100/200VAC, Ta=25°C and maximum output power.
*2. For cases where conformance to various safety specs (UL, CSA, EN) are required,
input voltage range will be 100-240VAC(50/60Hz).
*3. Measure with EIAJ RC-9131 probe, Bandwise of scope :100MHz.
*4. 85 - 265VAC , constant load.
*5. No load-Full load, constant input voltage.
*6. Constant current limit with automatic recovery.
*7. OVP circuit will shut down output, manual reset (Line recycle).
*8. At 100/200VAC nominal output voltage and maximum output current.
*9. Measured by the each measuring method of UL,CSA,EN and DENTORI(at 60Hz).
*10. Ratings - Derating at standard mounting.
- Load (%) is percent of maximum output power or maximum output current, whichever is greater.
- As for other mountings, refer to derating curve (A157-01-02_).
*11. As for DENTORI, built to meet at 100VAC.