NEMIC-LAMBDA JWS 50 SPECIFICATIONS A157-01-01A 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 MODEL JWS50 JWS50 JWS50 JWS50 JWS50 JWS50 ITEMS -3 -5 -12 -15 -24 -48 Nominal Output Voltage V 3.3 5 12 15 24 48 Maximum Output Current A 10 10 4.3 3.5 2.2 1.1 Maximum Output Power W 33 50 51.6 52.5 52.8 52.8 Efficiency (Typ) (*1) % 65 74 76 77 79 79 Input Voltage Range (*2) 85 - 265VAC (47-63Hz) or 120 - 330VDC Input Current (100/200VAC)(Typ) (*1) A 0.6/0.3 0.8/0.4 Inrush Current(Typ) 14A at 100VAC, 28A at 200VAC, Ta=25°C, Cold Start PFHC Built to meet EN61000-3-2 Power Factor (100/200VAC)(Typ) (*1) 0.99/0.95 Output Voltage Range V 2.85-3.63 4.5-5.5 10.8-13.2 13.5-16.5 21.6-26.4 43.2-52.8 Maximum Ripple & Noise 0 ~ +60°C mV 120 120 150 150 150 200 (*3) -10 ~ 0°C mV 160 160 180 180 180 240 Maximum Line Regulation (*4) mV 20 20 48 60 96 192 Maximum Load Regulation (*5) mV 40 40 96 120 150 240 Temperature Coefficient Less than 0.02%/°C Over Current Protection (*6) A 10.5 ~ 10.5 ~ 4.5 ~ 3.6 ~ 2.3 ~ 1.15 ~ Over Voltage Protection (*7) - 3.79-4.95 5.75-6.75 13.8-16.2 17.3-20.3 27.6-32.4 55.2-64.8 Hold-up Time (Typ) (*8) 20ms Leakage Current (*9) 0.75mA MAX, 0.2mA(Typ) at 100VAC / 0.44mA(Typ) at 230VAC Remote Sensing Parallel Operation Series Operation Possible Operating Temperature (*10) -10 ~+60°C ( -10 ~+50°C:100%,+60°C:60%) Operating Humidity 30 ~ 90%RH (No dewdrop) Storage Temperature -30 ~ +85°C Storage Humidity 10 ~ 95%RH (No dewdrop) Cooling Convection Cooling Withstand Voltage Input - FG : 2KVAC (20mA), Input - Output : 3KVAC (20mA) Output - FG : 500VAC (100mA) for 1min Isolation Resistance More than 100Mohm at 25°C and 70%RH Output - FG... 500VDC Vibration At no operating, 10-55Hz (Sweep for 1min) 19.6m/s2 Constant, X,Y,Z 1hour each. 2 Shock (In package) Less than 196.1m/s Safety (*11) Approved by UL1950, CSA950, EN60950,VDE0160. Built to meet DENTORI Conducted Emission Built to meet EN55011/EN55022-B, FCC-ClassB, VCCI-B. Radiated Emission Built to meet EN55011/EN55022-B, FCC-ClassB, VCCI-B. Weight(Typ.) g 350 Size (WxHxD) mm 37 x 85 x 159 ( Refer to Outline Drawing ) *Read instruction manual carefully, before using the power supply unit. =NOTES= *1. At 100/200VAC, Ta=25°C and maximum output power. *2. For cases where conformance to various safety specs (UL, CSA, EN) are required, input voltage range will be 100-240VAC(50/60Hz). *3. Measure with EIAJ RC-9131 probe, Bandwise of scope :100MHz. *4. 85 - 265VAC , constant load. *5. No load-Full load, constant input voltage. *6. Constant current limit with automatic recovery. *7. OVP circuit will shut down output, manual reset (Line recycle). *8. At 100/200VAC nominal output voltage and maximum output current. *9. Measured by the each measuring method of UL,CSA,EN and DENTORI(at 60Hz). *10. Ratings - Derating at standard mounting. - Load (%) is percent of maximum output power or maximum output current, whichever is greater. - As for other mountings, refer to derating curve (A157-01-02_). *11. As for DENTORI, built to meet at 100VAC. NEMIC-LAMBDA JWS 50 OUTPUT DERATING A157-01-02 Ta(°C) -10 ~+40 45 50 55 60 MOUNTING A 100 100 100 80 60 LOAD(%) MOUNTING B MOUNTING C 100 100 100 100 80 80 60 60 - MOUTING D 100 80 60 - OUTPUT DERATING CURVE 120 LOAD(%) 100 80 MOUNTING A MOUNTING B,C MOUNTING D 60 40 20 0 -10 0 10 20 30 40 50 60 70 Ta(°C) MOUNTING A (STANDARD MOUNTING) MOUNTING B MOUNTING C MOUNTING D DON'T USE NEMIC-LAMBDA JWS 50 SPECIFICATIONS A157-01-03B MODEL 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 ITEMS Nominal Output Voltage V Maximum Output Current A Maximum Output Power W Efficiency (Typ) (*1) % Input Voltage Range (*2) Input Current (100/200VAC)(Typ) (*1) A Inrush Current(Typ) PFHC Power Factor (100/200VAC)(Typ) (*1) Output Voltage Range V Maximum Ripple & Noise 0 ~ +60°C mV (*3) -10 ~ 0°C mV Maximum Line Regulation (*4) mV Maximum Load Regulation (*5) mV Temperature Coefficient Over Current Protection (*6) A Over Voltage Protection (*7) Hold-up Time (Typ) (*8) Leakage Current (*9) Remote Sensing Parallel Operation Series Operation Operating Temperature (*10) Operating Humidity Storage Temperature Storage Humidity Cooling Withstand Voltage - 28 Isolation Resistance 29 Vibration - 30 Shock (In package) 31 Safety (*11) - 32 33 34 35 Conducted Emission Radiated Emission Weight(Typ.) Size (WxHxD) g mm JWS50 JWS50 -9 -28 9 28 5.6 2.0 50.4 56.0 74 79 85 - 265VAC (47-63Hz) or 120 - 330VDC 0.8/0.4 14A at 100VAC, 28A at 200VAC, Ta=25°C, Cold Start Built to meet EN61000-3-2 0.99/0.95 8.1-9.9 25.2-30.8 150 150 180 180 36 112 76 160 Less than 0.02%/°C 5.88 ~ 2.10 ~ 10.4-12.2 32.2-37.8 20ms 0.75mA MAX, 0.2mA(Typ) at 100VAC / 0.44mA(Typ) at 230VAC Possible -10 ~+60°C ( -10 ~+50°C:100%,+60°C:60%) 30 ~ 90%RH (No dewdrop) -30 ~ +85°C 10 ~ 95%RH (No dewdrop) Convection Cooling Input - FG : 2kVAC (20mA), Input - Output : 3kVAC (20mA) Output - FG : 500VAC (100mA) for 1min More than 100Mohm at 25°Cand 70%RH Output - FG...500VDC At no operating, 10-55Hz (Sweep for 1min) 19.6m/s2 Constant, X,Y,Z 1hour each. Less than 196.1m/s2 Approved by UL1950, CSA950, EN60950,VDE0160. Built to meet DENTORI Built to meet EN55011/EN55022-B, FCC-ClassB, VCCI-B. Built to meet EN55011/EN55022-B, FCC-ClassB, VCCI-B. 350 37 x 85 x 159 ( Refer to Outline Drawing ) *Read instruction manual carefully, before using the power supply unit. =NOTES= *1. At 100/200VAC, Ta=25°C and maximum output power. *2. For cases where conformance to various safety specs (UL, CSA, EN) are required, input voltage range will be 100-240VAC(50/60Hz). *3. Measure with EIAJ RC-9131 probe, Bandwise of scope :100MHz. *4. 85 - 265VAC , constant load. *5. No load-Full load, constant input voltage. *6. Constant current limit with automatic recovery. *7. OVP circuit will shut down output, manual reset (Line recycle). *8. At 100/200VAC nominal output voltage and maximum output current. *9. Measured by the each measuring method of UL,CSA,EN and DENTORI(at 60Hz). *10. Ratings - Derating at standard mounting. - Load (%) is percent of maximum output power or maximum output current, whichever is greater. - As for other mountings, refer to derating curve (A157-01-02_). *11. As for DENTORI, built to meet at 100VAC.