GW-UDACT - Gamewell

GW-UDACT
Universal Digital Alarm
Communication Transmitter
Description
The Gamewell-FCI Universal Digital Alarm Communicator
Transmitter (GW-UDACT) is designed for use with all
Gamewell-FCI 600 Series Fire Alarm Control Panels. The
GW-UDACT transmits the system status to UL-Listed Central Station Receivers via the public switched telephone
network.
The GW-UDACT is compact in size and mounts directly in
the panel. RS-485 annunciator communications bus and
regulated 24-volt connections are required.
The GW-UDACT is capable
status of software zones:
•
Alarm and Trouble
•
System Trouble
•
Panel Off-Normal
•
Supervisory
of transmitting the following
GW-UDACT
•
•
•
Bell Trouble
Low Battery,
AC Fail
Features
The GW-UDACT is also capable of transmitting the status
of all zones associated with each panel. Reporting is in the
form of software zones or groups (up to 256). Each zone
can be programmed for fire, waterflow, supervisory, etc.
NOTE: Descriptions regarding point capacity, listed above,
are used for receivers which receive in the Ademco
Contact ID format. For compatible receivers, refer Table 1
on page 2.
Engineer’s Specifications
The Universal Digital Alarm Communicator Transmitter
(GW-UDACT) shall continuously supervise the state of
each of the two connected Telco Lines (at approximately
one-minute intervals) by a Line-DC level measurement. If
supervision fails, a Line #1 or Line #2 Trouble event will be
reported. Once a line has been restored, a Line Trouble
Restored event will be reported. The unit shall be capable
of reporting Alarm, Trouble, Supervisory, and Waterflow
events and event-specific restorals for each of up to 256
groups or software zones. The product will always report
events sorted in the order in which they are received/recognized.
The GW-UDACT shall be capable of reporting multiple
events to a single account number, within a single call session. Up to three attempts for a single message not yet
reported will be made within a single call attempt. A failure
to communicate to either or both accounts will generate a
corresponding event which will be queued for reporting.
The unit shall be a Gamewell-FCI model GW-UDACT.
•
•
•
•
•
•
•
•
•
Listed per ANSI/UL® 864, 9th Edition
Maximum of 14 point trouble messages transmitted
Dual phone lines and telephone line voltage detect
Surface-mount technology and mounts directly in
panel
Compact in size: 6.75" x 4.25" (17.145 x 10.795 cm)
Built-in programmer
Built-in four-character red seven-segment LED display
Manual test report function
Communicates vital system status including:
- Independent zone fire alarm and non-fire alarm
- Independent zone trouble and non-zone trouble
- Independent zone supervisory
- AC (mains) power loss (programmable)
- Low battery and earth fault
- System off-normal
- 12 or 24 hour test signal.
- Abnormal test signal per UL requirements
- RS-485 communication bus failure
•
•
•
•
•
•
Annunciation of UDACT troubles including: loss of
phone lines, communication failure with either central
station, total communication failure
Troubleshoot mode converts keypad to DTMF touchpad
Individual LEDs for: power, RS-485 loss, manual test,
kiss off, communication fail, primary line seize, secondary line seize, and modem communications
Open collector relay driver for total communications
failure or UDACT trouble
Real-time clock
Extensive transient protection
An ISO 9000-2000 Company
FM
UL® is a registered trademark
of Underwriters Laboratories, Inc.
S521
APPROVED
MEA
Approved
248-05-E 7300-1703:135
GAMEWELL-FCI
12 Clintonville Road, Northford, CT 06472 - Tel: (203) 484-7161 - Fax: (203) 484-7118
Specifications are for information only, are not intended for installation purposes, and subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use.
www.gamewell.fci.com
CS-2501 Rev. C page 1 of 2
©2008 Gamewell-FCI. All rights reserved.
Compatible Receivers
Table 1 lists the compatible receivers for the GW-UDACT.
Format #
(Addresses 16 & 42)
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
4 + 1 Ademco Express
4 + 2 Ademco Express
3 + 1/Standard/1800/2300
Ademco
685 (1)
Silent
Knight
9000
4
4
4
4 (2)
4
4 (2)
4
4 (2)
ITI
CS-4000
(3)
4
FBI
CP220FB
Osborne
Hoffman
Models
1&2
4
4
4 (4)
4 (8)
4
4 (4)
4
4 (4)
4
4 (4)
4
4 (4)
4
4 (4)
4
4
4
Radionics
600/
6500
(5)
Sescoa
300R
(7)
4 (5,6)
Sur-Gard
MLR-2
(9)
4
4
4
4
4
4
4
4
4
4
4
4
4
4
(NOT USED)
3+1/Standard/1900/1400
(NOT USED)
4+1/Standard/1800/2300
4
4 (5)
(NOT USED)
4+1/Standard/1900/1400
4
4 (2)
4
4 (2)
4
4 (2)
(NOT USED)
4+2/Standard/1800/2300
4
4 (5)
(NOT USED)
4+2/Standard/1900/1400
(NOT USED)
Ademco Contact ID
4
4F
(NOT USED)
Table 1: Compatible Receivers
(1)
(2)
(3)
(4)
(5)
(6)
(7)
(8)
(9)
With 685-8 Line Card with Rev 4.4d software.
With 9002 Line Card Rev 9035 software or 9032 Line Card with 9326A software.
Rev. 4.0 software.
FBI CP220FB Rec-11 Line Card with Rev 2.6 software and a memory card with Rev 3.8 software.
Model 6500 with Rev 600 software.
Model 6000 with Rev 204 software.
With Rev B control card at Rev 1.4 software and Rev C line card at Rev 1.5 software.
Model 2 only.
Version 1.62 software.
Specifications:
Ordering Information:
Electrical
Part Number
Model
Input Voltage:
24 VDC
Standby Current:
0.040 A
Current While Communicating: 0.075 A
Nominal Voltage:
24 volts DC
Communication Formats:
• 3+1 Standard
• 4+1 Standard
• 4+2 Standard
• 4+1 and 4+2 Ademco Express
• Ademco Contact ID
Note: The Ademco Contact ID must be used for independent zone reporting.
Mounting:
When the GW-UDACT is used with the Gamewell-FCI
600 Series, the GW-UDACT mounts directly in the panel
cabinet.
Relative Humidity:
93% non-condensing
Temperature Rating:
32° F - 120° F
(0° C - 49° C)
GW-UDACT
Gamewell-FCI Universal Digital Alarm
Communicator Transmitter for use with
the Gamewell-FCI 600 Series panels.
Includes operating and programming
instructions, and mounting.
DACT phone cord, 7 ft. (2.13 m) long
(two required).
MCBL-7
GAMEWELL-FCI
12 Clintonville Road, Northford, CT 06472 - Tel: (203) 484-7161 - Fax: (203) 484-7118
CS-2501 Rev. C page 2 of 2
www.gamewell.fci.com