Data Sheet

411/411UD
Features
Slave Digital Alarm Communicator Transmitter
Description
The Gamewell-FCI 411 and
411UD are compact, multifaceted, slave Digital Alarm Communicator Transmitters (DACTs)
designed for a variety of fire,
security, and non-fire applications. The series consists of two
models: the 411 and 411UD,
providing three and four monitoring channels (inputs) respectively. These slave DACTs are a
cost-effective solution for applicag2508ph1.jpg
tions that require an existing (or
new) Fire Alarm Control Panel to
transmit system status to an offsite monitoring facility for Central or
Remote Station compliance. Due to extremely flexible programming options,
the 411 Series slave DACTs are also ideal for monitoring non-fire and
security control panels. With fifteen selectable transmission formats,
including ADEMCO Contact ID, compatibility with virtually all Digital
Alarm Communicator Receivers (DACR) is ensured. Programming can be
accomplished on-site with a hand-held programmer (PRO-411), or remotely
(411UD only) utilizing an optional PK-CD Windows®-based remote upload/
download software package. The PK-CD upload/download software also
permits system interrogation and revision from a remote site.
• Three (411) or four (411UD) monitoring
channels (inputs).
• Inputs may be individually programmed
to monitor the host control panel for:
Fire alarm, fire trouble, fire supervisory,
process monitoring, AC power loss, security
alarm and other (fire and non-fire events).
• Fully supervised trigger inputs require a
contact closure for activation.
• 12- or 24-VDC operation, jumper-selectable.
• Industry-first, UL recognized," dialer-runaway" prevention feature.
• Dual-line rotary- or Touch-Tone®-dial DACT
interfaces to public switched telephone
network (leased phone lines are not
required).
• Includes 15 reporting formats, including the
popular ADEMCO Contact ID format.
• Capable of transmitting the following
DACT information, in addition to vital
system status of the host control panel:
DACT troubles, telephone line 1 and 2
voltage fault, primary or secondary Central
Station communication fault, system offnormal, 24-hour normal test and 24-hour
abnormal test.
• New long-distance Carrier Access Code
(CAC) compliant, accepting up to 20-digit
Central Station telephone numbers.
• Fully programmable transmittal codes for
fire, security, process monitoring, and
others.
Housing
• Field-programmable utilizing PRO-411 handheld programmer.
The 411 and 411UD are fully enclosed in a compact housing measuring only
6.75" ( 17.145 cm) W x 4.40" (11.176 cm) H x 1.05" (2.667 cm) D. The overlay
includes large areas to independently mark programming options for the
three or four channels (inputs), relay, and also includes printed terminal
and diagnostic LED designations. The overall compact size of the enclosure
permits mounting of these DACTs in virtually any control panel's enclosure,
or alternately, adjacent to the host control panel.
Features continued on page 2.
Phone Line Connections
Two modular phone connections on the 411 and 411UD are accessible with
the cover in place and provide connections for two separate telephone lines
using standard RJ31X or RJ38X jacks. Both telephone lines are constantly
supervised for proper operation and integrity. Should one phone line go into
fault, and the remaining is operational, a report is sent to the central or
remote station.
411/411UD CS-2508
A
Page 1 of 4
• Programmable from remote site with
optional PK-CD programming software
(model 411UD only).
Listings
Listings and approvals below apply to
the basic 411/411UD communicator/
transmitter. In some cases, certain modules
may not be listed by certain approval
agencies, or listing may be in process.
Consult factory for latest listing status.
• UL Listed: file S2424.
• CSFM approved: file 7300-0075:174.
• MEA approved: file 328-94-E Vol. III
(411UD), 328-94-E Vol. IV (411), 328-94-E
Vol. VI (411UDAC).
Features continued...
Diagnostic LEDs
• View 411 Series status offsite in real time,
with optional PK-CD programming software,
without ever compromising monitoring
protection at the protected premises (model
411UD only).
Communication Fail (visible with front cover in place).
DACT Trouble (visible with front cover in place) (411UD).
Channel Active (visible with front cover in place) (411UD).
• Integral piezo sounder (both models) with
local silence switch (model 411UD only).
Primary Phone Line Active (411UD).
• One Form-C relay, fully programmable
(model 411UD only).
Secondary Phone Line Active (411UD).
Modem Active (411UD).
Ordering Information
411
411UD
Three-channel, dual-line, slave Digital Alarm Communicator Transmitter. Includes housing, operating and programming instructions. Requires PRO-411 hand-held
DACT programmer for local programming.
Same as above with four input channels, Form-C programmable relay, silence switch and remote upload/
download capability. Requires PRO-411 hand-held DACT
programmer for local programming or PK-CD Windowsbased programming software for remote programming and
real-time diagnostics.
• Complies with NFPA 72 — 1996 edition
(Central Station and Remote Station [DACT
only— not polarity reversal] Fire Alarm
Systems).
• Surface Mount Technology (SMT).
• Extremely compact enclosure, measuring
only 6.75" (17.145 cm) W x 4.40" (11.176
cm) H x 1.05" (2.667 cm) D.
Specifications: 411UD
Listings and Approvals:
NFPA 72 Central Station Fire Alarm
Systems, NFPA 72 Remote Station Fire
Alarm Systems. UL Standard 1635 Digital
Alarm Communicator/Transmitters, UL
Standard 864 Control Units for Fire Alarm
Systems.
PRO-411
Hand-held programmer for local programming of 411
Series DACTs.
PK-CD
Remote upload/download, Windows ® compatible programming software kit (for use with PK-Series only).
FCC Registration: OAAUSA-25431-AL-E.
Ringer Equivalence: 0.5 B.
MCBL-7
DACT phone cord, seven feet long (two required).
For Canadian Applications: IC Certificate
Number: 2132 9028 A. Ringer Equivalence Number (REN): 0.2.
Programming: A digital programming unit
with a keypad, model PRO-411. is available
for programming the 411 Series.
Windows® is a registered trademark of Microsoft Corporation.
Operating Power: The 411UD circuit board
operates on filtered 12 VDC. The configuration of Jumper J4 determines whether 12
VDC power is to be supplied directly to the
circuit board, or 24 VDC power is to be
supplied and then internally regulated down
to 12 VDC.
DC Power:
• J4 Jumper REMOVED: Filtered,
nonresettable and power-limited 24 VDC
(nominal) power must be supplied at TB1
Terminals 7(+) and 8(–). Current requirements are 100 mA in standby and 170 mA*
while communicating.
• J4 Jumper INSTALLED: Filtered,
nonresettable and power-limited 12 VDC
(nominal) power must be supplied at TB1
Terminals 7(+) and 8(–). Current requirements are 100 mA in standby and 170 mA*
while communicating.
*NOTE: A maximum of 300 mA is possible
with all channels active, the 411UD
communicating, the PRO-411 connected,
and Lamp Test active.
Page 2 of 4
411/411UD CS-2508
A
Specifications continued on page 4.
Compatible UL-Listed Receivers
The chart below shows UL-listed receivers compatible with 411 Series products:
Format # (addresses 16 & 42)
Ademco
685
(1)
Silent
Knight
9000
ITI
CS4000
(3)
FBI
CP220FB
0
4+1 Ademco Express
1
4+2 Ademco Express
2
3+1/Standard/1800/2300
(2)
(4)
3
3+1/Expanded/1800/2300
(2)
(4)
4
3+1/Standard/1900/1400
(2)
(4)
5
3+1/Expanded/1900/1400
(2)
(4)
6
4+1/Standard/1800/2300
(2)
(4)
7
4+1/Expanded/1800/2300
(2)
(4)
8
4+1/Standard/1900/1400
(2)
(4)
9
4+1/Expanded/1900/1400
(2)
(4)
A
4+2/Standard/1800/2300
(2)
(4)
B
4+2/Expanded/1800/2300
(2)
(4)
C
4+2/Standard/1900/1400
(2)
(4)
D
4+2/Expanded/1900/1400
(2)
(4)
E
Ademco Contact ID
Osborne
Hoffman
Models
1&2
Radionics
6000/6500
(5)
Sescoa
3000R
(7)
SurGuard
MLR-2
(9)
(8)
(5,6)
(5)
(5)
51735rec.tbl
KEY:
(1) With 685-8 Line Card with Rev 4.4d software.
(2) With 9002 Line Card Rev 9035 software or 9032 Line Card with 9326A software.
(3) Rev. 4.0 software.
(4) FBI CP220FB Rec-11 Line Card with Rev 2.6 software and a memory card with Rev 3.8 software.
(5) Model 6500 with Rev 600 software.
(6) Model 6000 with Rev 204 software.
(7) With Rev B control card at Rev 1.4 software and Rev C line card at Rev 1.5 software.
(8) Model 2 only.
(9) Version 1.62 software.
411/41UD
CS-2508
A
Page 3 of 4
Specifications: 411 continued...
Channels/Inputs:**
• Programmable Channels 1 through 4.
• Power-limited circuitry.
• Fully supervised.
• Operation: All channels NFPA Style B (Class
B). Requires Normally Open contact to trigger.
• Normal operating voltage: 12 VDC.
• Alarm current: 3.34 mA.
• End-of-line resistor: 2.2K ohms.
• Short-circuit current: 3.8 mA per channel/
input.
**NOTE: Channels/inputs do NOT support
two-wire smoke detectors.
Form-C Relay:
• Contact rating: 2.0 amps @ 30 VDC
(resistive).
Gamewell-FCI
12 Clintonville Road
Northford, CT 06472-1610
Phone: 203-484-7161
Fax: 203-484-7118
www.gamewell-fci.com
A Honeywell Company
© 2009 Gamewell-FCI
Specifications: 411
FCC Registration: OAAUSA-25431-AL-E.
Ringer Equivalence: 0.5 B.
For Canadian Applications:
IC Certificate Number: 2132 9028 A.
Ringer Equivalence Number (REN): 0.2.
Programming: A digital programming unit with
a keypad, model PRO-411, is available for
programming the 411 Series.
Operating Power: The 411 may be powered
from UL-listed control panels that output
nonresettable and power-limited 12 or 24
VDC power. The configuration of Jumper J4
determines whether 12 VDC power is to be
supplied directly to the 411 circuit board, or
24 VDC power is to be supplied and then
internally regulated down to 12 VDC.
DC Power: TB1 Terminals 1(+) and 2(–);
Terminal 3 is Earth Ground.
• J4 Jumper removed: nonresettable, and
power-limited 24 VDC (nominal) power must
be supplied at TB1 Terminals 1(+) and 2(–).
Operating voltage provided must be within
21.3 to 24.0 VDC (UL tested range: –15%,
+10%). Current requirements are 78 mA in
standby and 126 mA* while communicating.
• J4 Jumper installed: Filtered, nonresettable,
and power-limited 12 VDC (nominal) power
must be supplied at TB1 Terminals 1(+) and
2(–). Operating voltage must be within 11.2
to 12.4 VDC (UL tested range: –15%, +10%).
Current requirements are 78 mA in standby
and 126 mA* while communicating.
*NOTE: A maximum of 240 mA is possible
with all input channels active, the 411
communicating, the Programmer connected,
and Lamp Test active.
Channels/Inputs** —
TB2 Terminals 1 through 6:
•
•
•
•
•
•
•
•
•
Programmable Channels 1 through 3.
Power-limited circuitry.
Fully supervised.
Operation: All channels NFPA Style B (Class
B). Requires Normally Open contact to trigger.
Normal operating voltage: 12 VDC.
Maximum line resistance: 100 ohms per
channel.
Alarm current: 3.34 mA.
End-of-line resistor: 2.2K ohms, 1/2 watt (P/N
27070).
Short circuit current: 3.8 mA per channel/
input.
**NOTE: Channels/inputs do NOT support
two-wire smoke detectors.
Specifications and wiring information are provided for information only and are
believed to be accurate. Gamewell-FCI assumes no responsibility for their use.
Data and design are subject to change without notice. Installation and wiring
instructions shipped with the product shall always be used for actual installation.
For more information, contact Gamewell-FCI.
Page 4 of 4
411/411UD
CS-2508
A