ILI95-E3 Series Intelligent Loop Interface-Main Board Description ILI95-MB-E3 The Gamewell-FCI, Intelligent Loop Interface95-Main Board (ILI95-MB-E3) is the main circuit interface for the following E3 Series® Systems. • E3 Series Expandable Emergency Evacuation System • E3 Series Combined Fire and Mass Notification System With its state-of-the-art 32 bit RISC processor, this compact “panel on a board” provides a powerful addition to Gamewell-FCI’s single pair conductor solutions. This intuitive design provides the following features: • 2 signaling line circuits • auxiliary relay functions • 2 notification appliance • auxiliary power output circuits • local energy city box output These features, combined with a built-in network and serial protocols, allow this module to support a host of new and existing products, resulting in a building block approach to the fire alarm control panel design. The ILI95-MB-E3 is network ready and occupies 64 nodes, operating at 625K baud. In addition, the Addressable Node Expander (ANX) board expands the network to 122 nodes. When this sub-assembly is integrated with proven Broadband components, the result is a flexible yet powerful integrated audio solution. When the sub-assembly transmits to remote locations, the optional RPT-E3 provides the ILI95MB-E3 with valuable signal boosting and transient protection, as well as provides connectivity using both wire and fiber-optic cables. The ILI95-MB-E3 provides 2 signaling line circuits and terminals for the connections to up to 126 Apollo detectors and modules per SLC. The RS-485 interface can support up to a total of 6 LCD-E3 and 16 ASM-16 and/or 16 ANU48 remote LED driver modules. The ILI95-MB-E3 relay outputs include system alarm, supervisory, and system trouble contacts. The ILI95-MB-E3 provides output for a local energy city master box or for a remote location which is non power-limited. All other wiring is Class 2 power-limited. ILI95-MB-E3 Features ILI95-MB-E3 and ILI95-S-E3: Listed under UL® Standard 864, 9th Edition. Listed under UL Standard UL2572 for Mass Notification. Provides network ready integral 625K baud ARCNET. 115.2K baud RS-232. Signaling line circuits with: - 2 Class A, Style 6, 7* or Class B, Style 4 circuits - 40 Character user-defined text per device - Capacity of 126 analog/addressable devices per loop • 4100 Event History Log. *Style 7 wiring requires the use of XP95-LI Isolator Modules. • • • • • • ILI95-MB-E3 Only: • 2 notification appliance circuits, Class “A”, Style Z or Class B, Style Y rated at 2.0 amps. per circuit. • RS-485 supporting 16 ASM-16 switch modules and/or ANU-48 LED driver modules. • Alarm, trouble, and supervisory dry contacts Form “C”, rated at 2 amp. @ 30 VDC (resistive). • Supports six local/remote LCD-E3 annunciators and five LCD-7100/RAN-7100 remote LED annunciators. SIGNALING FM ® E3 Series is a registered trademark of Honeywell International Inc. UL® is a registered trademark of Underwriters Laboratories Inc. MEA Approved APPROVED FDNY #: 6175 S1869 3025415 COA # 231-06-E 7165-1703:0125 GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use. www.gamewell-fci.com 9021-60336 Rev. J page 1 of 2 ©2014 by Honeywell International Inc. All rights reserved. Specifications ILI95-MB-E3 Operating Current: Alarm Current: 0.050 amp 0.091 amp max. ILI95-S-E3 Operating Current: Alarm Current: 0.109 amp 0.11 amp ILI95-MB-E3 and ILI95-S-E3 Operating Voltage: ILI95-S-E3 ILI95-S-E3 The Intelligent Loop Interface95 - Expansion Board (ILI95S-E3) provides the E3 Series control panel with 2 additional signaling line circuits. The layout is similar to the ILI95-MB-E3 except a number of components are omitted. The ILI95-S-E3 occupies one node on the Broadband network. The ILI95-S-E3 provides 2 signaling line circuits and terminals for the connections to up to 126 sensors / modules. Installation Typically, the ILI95-MB-E3 or ILI95-S-E3 can be mounted in the following E3 Series cabinets: • Cabinet B and D, backbox • Cabinet B, B-Slim-E3 sub-assembly plate • Cabinet C, E3-ILI-C sub-assembly plate • Cabinet C, E3-INCC-C sub-assembly plate • Cabinet C, E3-INX-C sub-assembly plate • Cabinet D, E3-INCC-D sub-assembly plate • Cabinet D, E3-INX-D sub-assembly plate 24 VDC FWR (from the PM-9/ PM-9G Power Supply) Operating Temperature: 32° to 120° F (0° to 49° C) Relative Humidity: 0 to 93%, non-condensing at 90° F (32° C) Supervised Class 2 Power-limited SLC 40 Ohms maximum line impedance. 0.5 µf maximum line capacitance. Ordering Information Part Number Description ILI95-MB-E3 ILI95-S-E3 Intelligent Loop Interface-Main Board Intelligent Loop Interface-Expansion Board For installation instructions on the ILI95-MB-E3 or ILI95-S-E3, refer to the following documents: • E3 Series® Expandable Emergency Evacuation Installation/Operation Manual, Part Number: 9000-0574 • ILI95-MB-E3 Installation Instructions, Part Number: 9001-0017 • ILI95-S-E3 Installation Instructions, Part Number: 9001-0018 For information on the ANX, refer to the Data Sheet Part Number: 9021-60497. For additional information on the ILI-MB-E3 or ILI-S-E3, refer to the following document: • ILI-E3 Series Data Sheet, Part Number: 9020-0605 GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 9021-60336 Rev. J page 2 of 2 www.gamewell-fci.com