9021-60718

SL-2000 Series
Duct Smoke Detectors
Hi-Temp, Low-Flow and No-Tools
Description
The SL-2000 Series Smoke Duct Detector is the latest
innovation for early detection of smoke and products of
combustion present in air moving through HVAC ducts in
Commercial, Industrial, and Residential applications. The
unit is designed to prevent the recirculation or spread of
smoke by air handling systems, fans, and blowers. Complete systems may be shut down in the event of smoke
detection. The SL-2000 is designed and built to meet all
local code requirements, as well as the NFPA and ICC
standards regarding HVAC supply and return duct smoke
detectors. Output terminals are provided for a wide range
of remote accessories such as horns, strobes, remote status indicators, and test/reset key switches or push buttons.
The SL-2000 includes many features that represent true
innovations from current generation duct smoke detectors.
Our traditional installer/service-friendly approach has been
closely followed and expanded throughout the SL-2000.
This philosophy provides a.the installer/service and enduser. Our attention to detail has yielded a host of “No-Tools
Required” features, as well as a multi-application performance level as yet unmatched in the industry. Innovative
product combined with unsurpassed customer service
equals the right combination for all of your projects. The
key features below detail many of the customer-driven
innovations incorporated in the SL-2000 Series.
Engineers & Architects Specifications
The following items list the Engineers and Architects specifications.
• Air duct smoke detectors shall be Air Products and Controls Inc. SL-2000 Series. For ionization detectors the
model number is SL-2000-N.
• For photoelectric detectors the model number is SL2000-P. The detectors shall be listed by Underwriters
Laboratories per UL 268A.
• The detectors shall operate at air velocities from 100
feet per minute to 4,000 feet per minute and at temperatures of no greater than 140°F (60°C).
• Visual indication of alarm and power must be provided
on the detector front.
• A manual reset switch shall be located on front of the
device.
• Detector head shall not require additional filters or
screens which must be maintained, and shall include
both a standby and alarm visual indication.
SL-2000 Series
Features
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Low-Flow Technology: Both Ionization and Photoelectric models
listed for velocities between 100-4000 ft./min
Both models listed for high-temperature applications
Operating voltages: 230VAC, 115VAC, 24VAC, 24VDC
Interconnect up to 30 units for common functions
Patent pending “No-Tools Required” front or rear loading and removing sampling/exhaust tubes
Patent pending “Test Port Valve” allows for aerosol smoke testing
without cover removal
Provides a clear cover fitted with four captive “No-Tools Required”
thumbscrews
Instantaneous cover removal trouble indication
Staggered terminal blocks for easier wiring
Flashing LED on detector head indicates
normal operation
Magnet test capability (magnet included)
More wiring space than competitive models
Footprint allows easy retrofit in many applications without additional
drilling
Over 15 remote accessories available
Duct wall gaskets on back of enclosure are pre-installed
Compatible with the WP-2000 weatherproof enclosure
MEA
73-92-E 3240:1004:0105
UL268A
UROX
Vol. 27
UROX7
File #:S2829
GAMEWELL-FCI
12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118
Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use.
www.gamewell-fci.com
9021-60718 Rev. B page 1 of 2
©2013 by Honeywell International Inc. All rights reserved.
Engineers & Architects Specifications
Features (Continued)
• The housing shall contain a detector base which will
accept photoelectric or ionization detector heads.
• Terminal connections shall be of the screw type, a minimum of #6 screw (#12 to #22 AWG compatible). Terminals shall be provided for remote pilot, remote alarm
indications, strobe/horn, and remote test/reset switch.
All wiring must comply with local codes and regulations.
• A method of testing the alarm function with a magnet
must be provided.
• A method of smoke testing the detector without removing the cover must be provided.
• All unit, remote accessory, and common function connection designations must be permanently affixed to the
unit.
• Cover and sampling/exhaust tube installation or
removal must not require the use of tools.
• Capability for interconnection of up to 30 units shall be
provided for common functions.
• Sample and exhaust tubes shall be capable of removal/
installation from the front and/or rear of the detector for
inspection/maintenance.
• Reset switch is also an alarm test switch - competitive
models require a magnet or cover removal to test at unit
• Unit includes green pilot and red alarm visual indicators
• External mounting tabs do not require cover removal to
install
• Colored cover gasket indicates proper cover seal
• Compact, lightweight size means easy handling, lower
shipping costs
• Two sets of 10A form “C” alarm contacts:
- One set of 2A form “A” alarm contacts
- One set of 10A form “C” trouble contacts
• Large terminal connection screws
• Standard interchangeable “plug-in” UL Standard 268
photoelectric or ionization heads
• Advance detector head design yields internal dust filtering
• No additional screens or filters to clean
• Compatible with building automation and fire alarm systems
• Ionization and photoelectric versions available
• Complete wiring details permanently attached to unit
Wiring
Figure 1 Wiring
Specifications
Ordering Information
Power Requirements
(without accessories)
Standby
Alarm
Part Number Description
230 VAC 8 mA
230 VAC 18 mA SL-2000-N
Ionization: 230VAC, 115VAC, 24VAC, 24VDC
115 VAC 14 mA
115 VAC 32 mA SL-2000-P
Photoelectric: 230VAC, 115VAC, 24VAC, 24VDC
24 VAC 55 mA
24 VAC 190 mA Detector Model Number
24 VDC 14 mA
24 VDC 68 mA
SL-2000-N
55000-225APO
Relay Contact Rating:
Resistive Load
SL-2000-P
55000-328APO
Alarm Contacts:
2 sets form “C” rated at 10 Amps@115VAC Sampling Tubes
1 set form “A” rated at 2 Amps
STN-1.0
Sampling tube for 12" or less duct width
Trouble Contacts: 1 set form “C” rated at 10 Amps @ 115 VAC STN-2.5
Sampling tube for 6" to 2.5' duct width
Air Velocity
100 to 4,000 ft./min.
STN-5.0
Sampling tube for 2.5' to 5.0' duct width
Ambient Temperature:
STN-10.0
Sampling tube for 5.0' to 10.0' duct width
SL-2000-N
32° F to 158° F (0° C to 70° C)
Dimensions: 13 ½" L x 4 ½" W x 2 ¼" H
SL-2000-P
32° F to 140° F (0° C to 60° C)
MAX. NET WT. 2 1/2 lbs.
Humidity:
85 ±5% RH (@32 ±2° C; 86 ±3.6° F)
(Non-Condensing/Non-Freezing)
Wiring:
Solid or stranded: #12 to #22 AWG terminals Accessories
Radioactive Element: For SL-2000-N (Ionization) Americium 241; MS- and MSR-Series remote accessories, WP-2000 weather0.9 Micro-Curie Do not expose to corrosive proof enclosure, TG-2000 aerosol test gas, and T-PB power supatmospheres
plies (All available from Air Products and Controls Inc.)
Hardware:
7" exhaust tube, sampling tube end cap,
mounting template, test magnet, and
mounting hardware included
Material:
Grey plastic backbox, clear plastic cover
(Makrolon 94V-0)
GAMEWELL-FCI