SYSTEMSENSOR D4120

4-Wire Photoelectric Duct
Smoke Detector
The InnovairFlex™ Series are the only duct smoke
detectors flexible enough to fit configurations from
square to rectangular and everything in between.
Features
•Photoelectric, integrated low-flow technology
•Air velocity rating from 100 ft/min to 4,000 ft/min (0.5 m/s to 20.32
m/sec)
•Versatile mounting options: square or rectangular configuration
•Plug-in sensor offers superb false alarm immunity and the latest
sensor technology
•Broad ranges for operating temperature (–4°F to 158°F) and
humidity (0% to 95% non-condensing)
•Patented sampling tube installs from front or back of the detector
with no tools required
•Increased wiring space with a newly added ¾-inch conduit
knockout
•One easy-access Test/Reset button and improved LED status
•Patented interconnect feature for multi-fan shutdown
•New high contrast terminal designations
•Built-in short circuit protection from operator wiring errors
•Field selectable settings for configuring the detector
•Two DPDT Form-C relay contacts
•24 VAC/DC or 120VAC
•Backward compatibility with existing Innovair products, including
remote accessories
Agency Listings
The InnovairFlex D4120 4-wire photoelectric duct smoke
detector features a pivoting housing that fits both square and
rectangular footprints and mounts to round or rectangular ductwork.
This unit senses smoke in the most challenging conditions, operating
in airflow speeds of 100 to 4,000 feet per minute, temperatures
of –4°F to 158°F, and a humidity range of 0 to 95 percent (noncondensing). A plug-in sensor head offers improved false alarm
immunity and simple installation, testing, and maintenance. An
improved cover design isolates the sensor head from the low-flow
feature for simple maintenance.
The InnovairFlex housing provides ample wiring space, a ¾-inch
conduit knockout, and built-in short circuit protection to prevent
damage to sensitive components during installation. High contrast
terminal designations make wiring easy. With its 2:1 sensor-to-power
capability, the power board of the D4120 may be used to monitor
a second sensor ,D4S, simultaneously (i.e., supply and return side).
As many as 50 InnovairFlex detectors can be interconnected. When
one unit senses smoke, all interconnected detectors will switch
their relays; only the detector sensing smoke will go into alarm, thus
pinpointing the fire source.
An easy-access Test/Reset button makes it possible to test the unit
with the cover on. Three DIP switches can be used to configure field
selectable settings: cover tamper delay, number of sensors to be
controlled, and shut down on trouble option. Each power board
has two LEDs that can be used to indicate the status of connected
sensors, and a quick reference imprinted on the cover explains the
LED status indications (Standby, Maintenance, Trouble, and Alarm).
The InnovairFlex duct smoke detector can be customized to meet
local codes and specifications without additional wiring. The new
InnovairFlex product line is compatible with all previous Innovair
models, including remote test accessories.
WARNING: Duct smoke detectors are NOT a substitute for open
area smoke detectors; NOT a substitute for early warning detection;
NOT a replacement for a building’s regular fire detection system.
Refer to NFPA 72 and 90A for additional information.
InnovairFlex™ Duct Smoke Detector Specifications
Architectural/Engineering Specifications
The air duct smoke detector shall be a System Sensor InnovairFlex™ D4120 Photoelectric Duct Smoke Detector. The detector housing shall be UL listed per UL
268A specifically for use in air handling systems. The flexible housing of the duct smoke detector fits multiple footprints from square to rectangular. The detector
shall operate at air velocities of 100 feet per minute to 4000 feet per minute (0.5 to 20.32 meters/second). The unit shall be capable of controlling up to 50 air
handling systems when interconnected with other detectors. The detector shall be capable of providing a trouble signal in the event that the front cover is
removed. It shall be capable of local testing via magnetic switch, test button on the cover, or remote testing using the SSK451 Multi-Signaling Accessory or the
RTS451KEY Remote Test Station. Terminal connections shall be of the strip and clamp method suitable for 12–18 AWG wiring.
Physical Specifications
Size: (Rectangular Dimensions)
14.38 in (37 cm) Length; 5 in (12.74 cm) Width; 2.5 in (6.36 cm) Depth
(Square Dimensions)
7.75 in (19.7 cm) Length; 9 in (22.9 cm) Width; 2.5 in (6.35 cm) Depth
Weight:
2.5 lbs (1.14 kg)
Operating Temperature Range:
D4120 & D4S: –4° to 158°F (–20° to 70°C); D4P120: –40° to 158°F (–40° to 70°C)
Storage Temperature Range:
D4120 & D4S: –22° to 158°F (–30° to 70°C); D4P120: –40° to 158°F (–40° to 70°C)
Operating Humidity Range:
0% to 95% relative humidity non-condensing
Air Duct Velocity:
100 to 4000 ft/min (0.5 to 20.32 m/sec)
Electrical Ratings
Power supply voltage:
20–29 VDC
Input capacitance:
270 µF max.
Reset voltage:
3.0 VDC min.
Reset time: (with RTS451)
.03 to 0.3 sec.
Reset time: (by power down)
0.6 sec. max.
Power up time:
35 sec. max.
Alarm response time:
15 sec.
Sensitivity Test:
See detector label
Current Requirements: (Using No Accessories)
Max. standby current:
21 mA @ 24VDC
Max. alarm current:
65 mA @ 24VDC
24 VAC 50–60 Hz
270 µF max.
2.0 VAC min.
.03 to 0.3 sec.
0.6 sec. max.
35 sec. max.
15 sec.
See detector label
120 VAC 50–60 Hz
N/A
10 VAC min.
.03 to 0.3 sec.
0.6 sec. max.
35 sec. max.
15 sec.
See detector label
65 mA RMS @ 24VAC 60Hz
135 mA RMS @ 24VAC 60Hz
20 mA RMS @ 120VAC 60Hz
35 mA RMS @ 120VAC 60Hz
Contact Ratings
Alarm initiation contacts: (SPST)
2.0A @ 30 VDC (resistive)
Alarm auxiliary contacts: (DPDT)
10A @ 30 VDC (resistive); 10A @ 250 VAC (resistive); ½ HP @ 240 VAC ; ¼ HP @ 120 VAC
Note: Alarm auxiliary contacts shall not be connected to initiating circuits of control panels. Use the alarm initiation contact for this purpose.
Supervisory contacts: (SPDT)
2.0A @ 30 VDC (resistive); 2.0A @ 125 VAC (resistive)
Accessory Current Loads at 24 VDC
Device
Standby
Trouble
Alarm
APA151/APA451
12.5 mA
n/a
30 mA Max.
MHR/MHW
0 mA
n/a
29 mA Max.
RA400Z
0 mA
n/a
12 mA Max.
RTS451/RTS451KEY
0 mA/12 mA
n/a
12 mA Max.
SSK451
8 mA Max.
16 mA Max.
40 mA Max.
Note: Any combination of accessories may be used such that the given accessory loads are: 110 mA or less at the Aux output, and 50 mA or less at the Alarm output
Installing the InnovairFlex Sampling Tube
The InnovairFlex sampling tube may be installed from the front or back of the detector. The tube locks securely into place and can be removed by releasing
the front or rear locking tab (front locking tab shown below right).
A05-0419-000
Wiring for 4-wire Duct Smoke Detector and Accessories
POWER INPUTS (NOTE 1)
24VAC/DC
9
POWER INPUTS (NOTE 1)
120
VAC
120
VAC
24V
9
10
10
OR
OR
AUXILIARY CONTACTS
FOR FAN SHUTDOWN, ETC. (NOTE 2)
N.C.
16
AUX A
C.
6
N.O.
AUXILIARY CONTACTS
FOR FAN SHUTDOWN, ETC. (NOTE 2)
AUX A
N.C.
AUX B
C.
N.O.
N.C.
8
18
7
16
17
SUPERVISORY CONTACTS
(NOTE 3)
UL/FM LISTED
4-WIRE
CONTROL PANEL
C.
6
N.O.
17
N.C.
AUX B
C.
N.O.
8
18
7
SUPERVISORY CONTACTS
(NOTE 3)
SUP C.
SUP N.O.
SUP C.
SUP N.O.
3
14
3
14
EOL RESISTOR
SPECIFIED BY
PANEL
MANUFACTURER
+
ALARM
INITIATION
LOOP
ALARM
INITIATION
CONTACTS
(NOTE 4)
4
ALARM C.
5
ALARM N.O.
ALARM
INITIATION
CONTACTS
(NOTE 4)
FIRST DETECTOR IN THE LOOP
NOTE 1: 24V Power Inputs accept a non-polarized 24VDC or 24VAC 50-60Hz.
120VAC Power Inputs accept only 120VAC 50-60Hz. Connect power
source to appropriate terminals of each detector. See specifications
for additional power supply information.
NOTE 2: Auxiliary contacts shown in standby position. Contacts switch
during alarm as indicated by arrows. Auxiliary contacts are not to
be used for connection to the control panel. See specifications for
contact ratings.
4
ALARM C.
5
ALARM N.O.
LAST DETECTOR IN THE LOOP
NOTE 3: Supervisory contacts shown in standby position. Open contacts
indicate a trouble condition to the panel. See specifications for
contact ratings.
NOTE 4: Alarm Initiation contacts shown in standby position. Closed
contacts indicate an alarm condition to the panel. See specifications
for contact ratings.
*Please refer to the corresponding installation manual for accessory wiring diagrams.
Important Notes on 2:1 Sensor-to-Power Capability
• 2:1 sensor-to-power capability is not available for all InnovairFlex models. The feature is only available on the D4120 4-wire conventional models.
• 2:1 sensor-to-power capability can be enabled using one D4120 and one D4S, or two D4S and one D4P120.
Important Interconnect Notes
• When using the interconnect feature, all interconnected units must be powered using the same independent supply.
• Polarity must be maintained throughout the interconnect wiring. Connect the INT+ terminal on unit 1 to the INT+ terminal on unit 2 and so on. Similarly,
connect the INT/AUX– terminal on unit 1 to the INT/AUX- terminal on unit 2 and so on.
• Up to 50 D4120 units, 50 D4P120 units, or 50 units of combination may be interconnected.
• Up to 10 DH100ACDC units may be interconnected. Please note that each of the 9 DH100ACDC units interconnected may be replaced by three D4P120
units. Therefore, when using the interconnect feature a single DH100ACDC can drive either 9 DH100ACDCs or 27 D4120 units.
* NOTE: Alarm can be reset only at the initiating device and not at the devices interconnected.
A05-0419-000
Accessories
System Sensor provides system flexibility with a variety of accessories, including two remote test stations and several different means of
visible and audible system annunciation. As with our duct smoke detectors, all duct smoke detector accessories are UL listed.
RTS451KEY UL S2522
RTS451 UL S2522
RA400Z UL S2522
APA151 UL S4011
MHW UL S4011
SSK451 UL S2522
MHR UL S4011
SSK451 with PS24LOW strobe
and PS12/24 LENSW lens
Ordering Information
Part No.
D4120
Accessories
D4S
D4P120
2D51
DST1
DST1.5
DST3
DST5
DST10
APA151
DH400 OE-1
ETX
M02-04-00
Description
4-wire photoelectric low-flow duct smoke detector
4-wire photoelectric sensor component only
4-wire photoelectric power board component only,
24 VAC/DC, 120 VAC
4-wire conventional photoelectric sensor head
Metal sampling tube duct width up to 1ft (0.3m)
Metal sampling tube duct widths 1 ft to 2 ft (0.3 to 0.6 m)
Metal sampling tube duct widths 2 ft to 4 ft (0.6 to 1.2 m)
Metal sampling tube duct widths 4 ft to 8 ft (1.2 to 2.4 m)
Metal sampling tube duct widths 8 ft to 12 ft (2.4 to 3.7 m)
Remote annunciator with piezo alarm
Weatherproof enclosure
Metal exhaust tube duct width 1ft (0.3m)
Test magnet
MHR
MHW
Mini Horn, Red
Mini Horn, White
P48-21-00
PS12/24SLENSC
PS12/24SLENSW
PS24LO
PS24LOW
RA400Z
RTS451
RTS451KEY
SSK451
End cap for metal sampling tubes
Ceiling-mount “SMOKE” lens
Wall-mount “SMOKE” lens
Mini-Alert add-on strobe (red)
Mini-Alert add-on strobe (white)
Remote annunciator alarm LED
Remote test station
Remote test station with key lock
Multi-signaling accessory
3825 Ohio Avenue • St. Charles, IL 60174
Phone: 800-SENSOR2 • Fax: 630-377-6495
©2008 System Sensor.
Product specifications subject to change without notice. Visit systemsensor.com for
current product information, including the latest version of this data sheet.
A05-0419-000 • 8/08 • #1836