SL-DAA Series

SL-DAA Series
Analog Addressable Duct Detectors
(Hi-Temp, Low-FLow & No-Tools)
Description
The SL-DAA Series Smoke Duct Detector is the latest analog addressable innovation for early detection of smoke
and products of combustion present in air moving through
HVAC ducts in Commercial, Industrial, and Residential
applications. The unit is designed to prevent the recirculation or spread of smoke by air handling systems, fans, and
blowers. Complete systems may be shut down via the
building’s fire alarm control panel (FACP) in the event of
smoke detection. The SL-DAA is designed and built to
meet all local code requirements, as well as the NFPA and
ICC standards regarding HVAC supply and return duct
smoke detectors. Output terminals are provided for a
remote alarm indicator accessory.
The SL-DAA includes many features that represent true
innovations from current generation duct smoke detectors.
Our traditional installer/maintenance-friendly approach has
been closely followed and expanded throughout the SLDAA. This philosophy provides a new level of efficiency in
after-purchase value to both the installer/maintenance and
end-user. Our attention to detail has yielded a host of “NoTools Required” features, as well as a multi-application
performance level as yet unmatched in the industry. The
key features below detail many of the customer-driven
innovations incorporated in the SL-DAA Series. Innovative
product combined with unsurpassed customer service
equals the right combination for all of your projects.
Engineers & Architects Specifications
The following items list the Engineers and Architects specifications.
• Air duct smoke detectors shall be Air Products and Controls Inc. SL-DAA Series. For ionization detectors the
model number is SL-DAA-N.
• For photoelectric detectors the model number is SLDAA-P. The detectors shall be listed by Underwriters
Laboratories per UL 268A.
• The detectors shall operate at air velocities from 100
feet per minute to 4,000 feet per minute and at temperatures of no greater than 140° F (60° C).
• Visual indication of alarm must be provided on the
detector.
• Air handling unit shut down shall be accommodated via
the associated FACP.
• Detector head shall not require additional filters or
screens which must be maintained.
SL-DAA Series
Features
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Low-Flow Technology: Both Ionization and Photoelectric models
listed for velocities between 100-4000 ft./min
Both Ionization and Photoelectric models listed for high temperatureapplications
Units supplied with slide-in XPERT Card for easy device addressing
Patent pending “No-Tools Required” front or rear loading and removing sampling/exhaust tubes
Patent pending “Test Port Valve” allows for aerosol smoke testing
without cover removal
Clear cover fitted with four captive “No-Tools Required” thumbscrews
Instantaneous cover removal trouble indication
Vertical terminal block for easier wiring
Steady red LED on detector head indicates alarm
More wiring space than competitive models
Footprint allows easy retrofit in many applications without additional
drilling
Duct wall gaskets on back of enclosure are pre-installed
Compatible with the WP-2000 weatherproof enclosure
External mounting tabs do not require cover removal to install
Colored cover gasket indicates proper cover seal
MEA
UL268A,
73-92-E 3240:1004:0115
UROX, UROX7 Vol. 35
File #:S2829
GAMEWELL-FCI
12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118
Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use.
www.gamewell-fci.com
9021-60719 Rev. B1 page 1 of 2
©2015 by Honeywell International Inc. All rights reserved.
Engineers & Architects Specifications (Continued)
Features (Continued)
• The housing shall contain a detector base which will
accept photoelectric or ionization detector heads as well
as a means of detector addressing.
• Terminal connections shall be of the screw type, a minimum of #6 screw (#12 to #22 AWG compatible). Terminals shall be provided for remote alarm indication. All
wiring must comply with local codes and regulations.
• A method of smoke testing the detector without removing the cover must be provided.
• All unit and remote accessory connection designations
must be permanently affixed to the unit.
• Cover and sampling/exhaust tube installation or
removal must not require the use of tools.
• Sample and exhaust tubes shall be capable of removal/
installation from the front and/or rear of the detector for
inspection/maintenance.
•
•
•
•
•
•
•
•
•
Compact, lightweight size means easy handling,
lower shipping costs
Large terminal connection screws
XP95A interchangeable “plug-in” UL268 photoelectric
or ionization heads
Advanced detector head design yields internal dust filtering
No additional screens or filters to clean
Compatible with fire alarm systems utilizing Apollo
XP95 and/or Discovery protocol
Ionization and Photoelectric versions available
Complete wiring details permanently attached to unit
Wiring
Remote Accessory Wiring
Figure 1 Terminal Connections
Figure 2 Remote Accessory Wiring
Specifications
Ordering Information
Detector Compatibility: FACP using Apollo XP95 and/or
Discovery protocols
Air Velocity:
100 to 4,000 ft./min.
Ambient Temperature:
SL-DAA-N
32°F to 150°F (0°C to 66°C)
SL-DAA-P
32°F to 140°F (0°C to 60°C)
Humidity:
10 - 95% RH Non-Condensing /
Non-Freezing
Wiring:
Solid or stranded: #12 to #22 AWG
terminals
Radioactive Element: For SL-DAA-N (Ionization)
Americium 241;0.9 Micro-Curie
Do not expose to corrosive
atmospheres
Hardware
7” exhaust tube, sampling tube end
cap, mounting template & mounting
hardware included
Material
Grey plastic backbox, clear plastic
cover (Makrolon 94V-0)
Dimensions:
13 1/2” L x 4 1/2” W x 2 1/4” H
Max. Net Weight
2 lbs.
Part Number
Description
SL-DAA-N
SL-DAA-P
Sampling Tubes
STN-1.0
STN-2.5
STN-5.0
STN-10.0
Ionization
Photoelectric
GAMEWELL-FCI
Sampling tube for 12” or less duct width
Sampling tube for 6” to 2.5’ duct width
Sampling tube for 2.5’ to 5.0’ duct width
Sampling tube for 5.0’ to10.0’ duct width