Flex Series GWF402 and GWF404 Two and Four Zone Conventional Fire Alarm Control Panels Description The Flex 402 is a two zone fire alarm control panel (FACP) and the Flex 404 is a four zone FACP. These control panels provide reliable fire signaling protection for small to medium-sized retail, office, multi-family, or other similar commercial or institutional buildings. The Initiating Device Circuits (IDCs) for the Flex Series panels are categorized as Class 2 Power-Limited and operate in Class B (Style B). Each panel is compatible with the following types of conventional input devices. • two-wire smoke detectors • water flow devices • four-wire smoke detectors • tamper switches • pull stations In addition, each panel is compatible with other normallyopen contact devices. These devices include the System Sensor i3™ Series microprocessor-based detectors with advanced features like drift compensation, maintenance alert and freeze warning. Note: For a listing of compatible devices, refer to the Device Compatibility Document P/N: 52195. The outputs include one notification appliance circuit (NAC) on the Flex 402 and two NACs on the Flex 404. NACs are categorized as Class 2 Power-limited and operate in Class B (Style Y). Each FACP has a Form-C Alarm and Trouble relay and 24 VDC special applications resettable power. In addition, the Flex 404 has a Form-C Supervisory relay and a special application non-resettable power output. The FACP supervises wiring, AC voltage and battery level. The activation of a compatible smoke detector or any normally-open fire alarm initiating device will do the following: • Activate the audible and the visual signaling devices. • Illuminate an indicating LED. • Sound the piezo sounder at the FACP. • Activate the FACP alarm relay. • Operate any optional modules used to notify a remote station. • Initiate an auxiliary control function. GWF402/G (left) and GWF404 (right) Features • Listed under UL® Standard 864, 9th Edition. • Flex 402: Two Class B (Style B) IDC zones, one Class B (Style Y) NACs. • Flex 404: Four Class B (Style B) IDC zones, two Class B (Style Y) NACs. • Optional NAC Class A converter module (Flex 404). • Offers the following NAC synchronization and programmability features: – ADA compliant strobe synchronization. – ANSI audible signals as required by NFPA 72. – Silence inhibit, auto-silence, non-silenceable. – Selective Silence: mute horns, keep strobes lit. – Temporal or steady signal. • Displays silent or audible walk test from front keypad. • Zone disable, alarm verification selectable per zone. • Includes the following controls: – Acknowledge – Silence – Alarm – Walk Test – Reset – Zone enable/disable • Contains the following LED indicators: – Alarm – NAC fault – Supervisory – System/Power Trouble – Maintenance – Walk Test – Trouble (one per zone) – Alarm Silence – AC – Charger/Battery/ – NAC/Zone Disable Earth Fault (on pcb) • Provides alarm verification. • Uses a low AC voltage sense,automatic battery charger. • Has a Piezo sounder for alarm, trouble, and supervisory. SIGNALING MEA i 3™ is a trademark of Honeywell International Inc. UL® is a registered trademark of Underwriter’s Laboratories Inc. Approved FDNY: S521 COA-# 366-04-E 7300-1703:0161 GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use. www.gamewell-fci.com 9021-60292 Rev. D page 1 of 2 ©2013 Honeywell International Inc. All rights reserved. Options Specifications (Continued) CAC-4 Used to convert Class B (Style B) IDCs to Class A (Style D) and Class B (Style Y) NACs to Class A (Style Z). Mounts in FACP. Flex 404 only. XRM-24 Second 100VA transformer for maximum accessory power. Mounts in FACP. Flex 404 only. 4XTMF Transmitter module provides output for the local energy municipal box transmitter and alarm and trouble reverse polarity. Mounts in FACP. Flex 402 & Flex 404. 4XZMF Zone relay module provides Form-C relays: Alarm Zones 1, 2, 3, 4, System Alarm, Trouble. Mounts in FACP. Flex 404 only. 4XLMF LED interface module supports the GWSAN-404 remote annunciator, supervises annunciator wiring for open conditions. Mounts in FACP. Flex 404 only. 411UD Four input/channel, dual line, digital alarm communicator/transmitter (DACT). Input/ channels are compatible with normally open relay contacts, are supervised and fully programmable. Interfaces with public switched telephone networks and compatible with most central station receivers. Flex 404 only. GWSAN-404 Remote annunciator mounts in single-gang electrical box, provides LED indication of Alarm Zones 1, 2, 3, 4; and System Trouble. Flex 404 only. Circuits (NAC) (Continued) Operating Voltage: Maximum signaling current: 2.5 A total (5.0 A Flex 404 with an optional transformer). Maximum Line Impedance: 1.5 volt drop Form-C Relays: Contact Ratings: Resettable: Operating voltage: nominal 24 VDC Power: Class 2 Power-Limited circuitry Maximum Available Current: 500 mA Non-resettable: Operating voltage: nominal 24 VDC Power: Class 2 Power-Limited circuitry Maximum Available Current: 500 mA Cabinet Dimensions: Door: 15.3" x 14.7" x 0.3" (39 x 37 x 1 cm) Backbox: 15.0" x 14.5" x 3.0" (38 x 37 x 8 cm) Ordering Information GWF402 GWF404 71252 52194 Specifications AC Power: Battery: Initiating Device: Circuits (IDC): Operation: Power: Operating Voltage: Alarm Current: Short Circuit Current: Standby Current: Maximum Loop Resistance: Notification: 120 VAC, 50/60Hz, 2.3 A Max. charging circuit: 27.6 VDC@ 0.8A Max. charger capacity: 18 Ah (Two 7Ah batteries fit inside the FACP). Alarm zones 1 & 2 (Flex 402 / Flex 404) Alarm zones 3 & 4 (Flex 404 only) All zones Style B (Class B) Class 2 Power-Limited circuitry Nominal 20 VDC 15 mA minimum CAC-4 XRM-24 4XTMF 4XZMF 4XLMF 411UD Circuits (NAC): Operation: Class B (Style Y) Power: Class 2 Power-Limited circuitry Operating Voltage: Nominal 24 VDC Flex 402 conventional FACP, 2 zones, 120 VAC, red Flex 404 conventional FACP, 4 zones, 120 VAC, red EOL resistor, 4.7K ohm, ½ watt Flex 402 and Flex 404 Installation & Operation Manual Options: 40 mA maximum 4 mA 100 ohms One NAC: Flex 402 Two NACs:Flex 404 Trouble, Alarm (Supervisory, Flex 404) 2 A @ 30 VAC (resistive) PRO-411 GWSAN-404 BB-17F Class A converter for initiating device circuits and notification appliance circuits (cannot be used on Flex 402). Transformer, expands NAC circuit power from 3 to 5 amps. Transmitter module for remote station output or municipal box connection. Relay module, four relays-by-zone, alarm and trouble contacts, 24VDC. Remote annunciator driver, 24 VDC, supports GWSAN-404. Four channel dual slave programmer DACT, Form C relay and upload/ download capability; with enclosure, requires PRO-411. Programmer, use with 411UD, 411UDAC. LED remote annunciator for Flex 404, four alarms, one trouble (requires 4XLMF). Battery box, houses 2 batteries (7-18 Ah max.). GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 9021-60292 Rev. D page 2 of 2 www.gamewell-fci.com