MS-7 Series Non-Coded, Manual Fire Alarm Stations Description The Gamewell-FCI, MS-7 Series manual fire alarm stations are available in a wide variety of configurations. The Stations comply with the Americans with Disabilities Act (ADA) 5-lb. maximum pull force requirement. Operating instructions and Braille text are engraved in the handle. All stations have a key lock/reset which is keyed alike with Gamewell-FCI fire alarm control panels and other manual fire alarm stations. MS-7AF Velociti Addressable Station The MS-7AF Velociti® Series addressable station is a double action station designed for installation in the signaling line circuit of Gamewell-FCI analog addressable control panels. Activation of the station causes its assigned address to register at the control panel. The door contains an LED which flashes green in normal condition and lights steady red when the station has been activated.* The station features screw terminals. MS-7ASF Velociti Addressable Station The MS-7ASF Velociti® Series addressable station is a single action station designed for installation in the signaling line circuit of Gamewell-FCI analog addressable control panels. Activation of the station causes its assigned address to register at the control panel. The door contains an LED which flashes green in normal condition and lights steady red when the station has been activated.* The station features screw terminals. The Velociti® Series stations use a communication protocol that substantially increases the speed of communication between the sensors and certain Gamewell-FCI analog addressable fire alarm controls. These devices operate in a grouped fashion. If one of the devices in the group has a status change, the panel’s microprocessor stops the group poll and focuses on the single device. The net effect is response speed up to five times greater than earlier designs. MS-7 Double Action Station The MS-7 double action station is used with conventional fire alarm control panels. It features a set of single pole contacts and screw terminals for connection to an initiating circuit. Velociti® is a registered trademark of Honeywell International Inc. MS-7 Features • Addressable stations compatible with all Gamewell-FCI analog addressable fire alarm controls • Conventional stations suitable for use with any UL® Listed control panel • Both single and double action stations available • Tumbler lock for test and reset keyed alike with Gamewell-FCI controls • Surface or semi-flush mounting • Shock and vibration resistant • Stations (MS-7LOB) Listed for outdoor applications • Complies with ADA pull force requirements *Only the red LED is operative in panels that do not operate in Velociti mode. SIGNALING FM UL® is a registered trademark of Underwriter’s Laboratories Inc. MEA Approved S2465 3023594 67-02-E Vol.VIII 7150-1703:0119 7150-1703:0170 7150-1703:0109 APPROVED LEXAN® is a registered trademark of GE Plastics, a subsidiary of General Electric Company. GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use. www.gamewell-fci.com 9020-0616 Rev. E page 1 of 2 ©2013 by Honeywell International Inc. All rights reserved. Specifications MS-7S Single Action Station The MS-7S single action station is used with conventional fire alarm control panels. It features a set of single pole contacts and wire leads for connection to an initiating circuit. Material: Contact Ratings: Lexan® 0.25 amps. @ 30 VAC/VDC (resistive) 5 5/8” H x 4 1/4” W x 1 1/4” D (14 x 10.1 x 3.2 cm) MS-7SP Double Action Station The MS-7SP is a double action station similar to the MS-7 station, with the additional feature of both English and Spanish instructions molded into the unit. MS-7LR Dual-action Agent Release Station The MS-7LR is designed for use with the Gamewell-FCI fire alarm control panels with releasing capabilities and Flex Series releasing systems. It features a set of single pole contacts and screw terminals for connection to an initiating circuit. MS-7LRA Agent Release Station with Abort The MS-7LRA is designed for use with the Gamewell-FCI fire alarm control panels with releasing capabilities and Flex Series releasing systems where system abort capabilities are required. It consists of an MS-7LR mounted on a plate with an abort switch and LED indicators for system normal, and system activated status. MS-7LOB Double Action Station (Listed for Outdoor Applications) Dimensions: Operating Temperature (MS-7AF, MS-7ASF): (MS-7LOB): Relative Humidity (MS-7AF, MS-7ASF): (MS-7LOB): Alarm Current: Supervisory Current (MS-7AF, MS-7ASF): 32° to 120° F (0° to 49° C) -30° to 150° F (-35° to 66° C) 10 to 93% (non-condensing) 85% ± 5% @ 86° ± 3.6° (30° ± 2° C) .0030 amp. 0.007 for LED .00030 amps. Ordering Information Part Number Description MS-7 MS-7AF** The MS-7LOB station must be mounted on a Model SB-I/O backbox. In retrofit applications, the station is UL Listed for use with the WP-10 backbox. It is intended for use with conventional control panels and has a set of single pole contacts and screw terminals. Mounting The MS-7 interior stations may be surface mounted or semi-flush mounted on a standard double-gang, or 4-inch (10.2 cm) square electrical box. An optional trim ring (BG12TR) may also be used for semi-flush mounting. NYC-Plate The NYC-Plate provides the backplate for the manual pull station. (See Figure 1). Double action station Velociti addressable double action station MS-7ASF** Velociti addressable single action station MS-7S Single action station, wire leads MS-7SP Double action station, English and Spanish instructions MS-7LR Agent release station, dual-action MS-7LRA Agent release station with abort switch, LED indicators, dual- action MS-7LOB Double action station, outdoor use (Includes SB-I/O - Indoor/outdoor use backbox) SB-I/O Indoor/outdoor use backbackbox SB-10 Surface backbox BG12TR Trim ring for semi-flush mount, plastic NY-PLATE NYC backplate for manual pull station **For use with the Gamewell-FCI analog addressable control panels only. Figure 1 NYC-Plate GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 9020-0616 Rev. E page 2 of 2 www.gamewell-fci.com