FAAST® 9400X Conventional FAAST Fire Alarm Aspiration Sensing Technology Description The Gamewell-FCI, FAAST XT®, 9400X aspirating smoke detectors deliver highly accurate Very Early Warning Fire Detection over a wide coverage area and offer extensive communication applications. This aspirating smoke detector combines advanced particle separation with a unique dual source optical smoke detection technology to provide highly sensitive Very Early Warning Fire Detection while providing enhanced immunity to false alarms. This technology enables FAAST XT to accurately detect incipient fire conditions as early as 60 minutes before a fire actually starts when set for Early Warning and Very Early Warning Fire Detection in applications ranging from mission critical to harsh and extreme environments. An installed FAAST XT device can protect up to 28,800 sq. ft. (2,676 sq. m) in the standard coverage type applications and can be monitored in several different ways, including the following: • Serial or TCP Modbus • Direct PC connection • Ethernet over a LAN • FAAST XT’s onboard USB When the 9400X is connected to a LAN, FAAST XT’s email server can email event notification to the appropriate personnel. FAAST XT also communicates alarm and fault conditions via Form C Relays. PipeIQ® is FAAST XT’s intuitive design, configuration, and monitoring software. The all-in-one program can be used to do the following: • Create a pipe network tailored to meet site specific requirements. • Configure a FAAST XT device. • Monitor an installed device including the following: - live trending - reading of historic reports *A complimentary download of PipeIQ is available at systemsensor.com/faast. 9400X Features • Provides Very Early Warning Fire Detection, as precise as 0.00046%/ft obscuration. • Includes five alarm levels and two sensitivity modes to provide application flexibility. • Has user-configurable 3-speed fan, allowing for maximum coverage area or minimizing current consumption. • Delivers ultrasonic flow sensing for each pipe inlet and chamber airflow monitoring for precise system health information. • A single device can cover up to 28,800 square feet. • Combines a dual source optical detection chamber with enhanced algorithms to provide high sensitivity with greater immunity to nuisance conditions. • Delivers a patented particle separator to remove large, non-fire particulate, ensuring chamber health and extending the life of the field-replaceable filter. • Converts TCP and Serial modbus for easy integration with building management systems. • Offers easy configuration via USB interface, no power needed. • Supports an on-board Ethernet interface that enables remote monitoring and email notification. • Displays an LCD user interface that allows for detailed device information and interaction such as the following. - Active faults - Reset of airflow baseline - Test/reset/isolate - Precise airflow monitoring • Produces configurable air flow fault thresholds and verification period. • Designed with convenient wiring compartment. • Shows the status-at-a-glance that provides immediate alarm, fault and airflow status. SIGNALING PipeIQ™ is a trademarks of Honeywell International Inc. ® FAAST XT is a registered trademark of System Sensor Inc. ® UL is a registered trademark of Underwriter’s Laboratories, Inc. S1913 7259-1653:0236 GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use. www.gamewell-fci.com 9021-60840 Rev. A page 1 of 2 ©2014 by Honeywell International Inc. All rights reserved. Specifications Specifications (Continued) Conventional FAAST XT Specifications Electrical Specifications Networking Specifications (Continued) External Supply Voltage 18-30 VDC Remote Reset Time External monitor must be pulled low for a minimum of 100 ms Power Reset 1 second Avg. Operating Current Fan High - 465mA, 11.2W Fan Med - 340mA, 8.2W Fan Low - 220mA, 5.3W Alarm Current Fan High - 493mA, 11.85W Fan Med - 368mA, 8.85W Fan Low - 248mA, 6W Relay Contact Ratings 3.0 A @ 30 VDC 0.5 A @ 125 VAC 8 form C 3 AMP, programmable latching or non-latching Ethernet Modbus Email Webserver 10/100Mbps, MDI-X TCP or Serial RS6 recipients, sel. notifications Read Configuration, Live View, Logs Configuration Specifications PipeQ Modbus USB or Ethernet Ethernet or RS-485 Figure 1 illustrates the FAAST XT user interface display. Environmental Ratings Operating Temperature 32°F (0°C) to 100°F (38°C); Factory Tested to 133°F (55°C) Sampled Air Temperature -4°F (-20°C) to 140°F (60°C) Humidity Range 10 to 95% (non-condensing) Sensitivity Range 0.00046% Obs/ft to 6.25% Obs/ft (0.0015% Obs/m to 20.5% Obs/m) IP Rating IP30 Coverage Area 28,800 sq.ft. (2,676 sq.m) Air Movement 0-4,000 ft./min. (0-1,219 m/min.) Physical Specifications Height Width Depth Cable Access Wire Gauge Maximum Single Pipe Length Total Pipe Length 13.3 in (338 mm) 13.1 in (333 mm) 7.5 in (191 mm) 4 1-inch (2.54 cm) cable entry holes located on top, bottom and back of the unit 12 AWG (2.05 mm) max. to 24 AWG (0.5 mm) min. 400 ft. (123 m) (*other there pipes disabled) 1050 ft. (320 m) (*all designs must be verified within PipeIQ software) 262 ft. per pipe Multiple Pipe Network Network Outside Pipe Diameter 1.050 inches, IPS (25 mm) Internal Pipe Diameter 0.591 to 0.827 inches (15-21 mm) Sensitivity Range 0.00046%Obs/ft to 6.25% Obs/ft (0.0015%Obs/m to 20.5%Obs/m) Relays 8 Form C, 3 AMP, programmable latching or non-latching Figure 1 - FAAST XT User Interface Display The User Interface consists of 5 Alarm levels: • Alert • Fire 1 and Fire 2, 10 Particulate levels • Action 1 and Flow and Fault graph • Action 2 Ordering Information Part Number 9400X Description System Sensor Conventional FAAST Fire Alarm Aspiration Sensing Technology Accessories Various† UL®-Approved Pipe and Fittings † Additional accessory information, including part numbers, can be accessed at systemsensor.com/faast. Diagnostic Specifications Event Log Trend Data Log Service Log 18,000 events stored Configurable sampling period (1 minute to 1 day) 300 custom user entries Networking Specifications Communication Network Network Services Ethernet monitoring, 6 E-mail address alerts, TCP and Serial Modbus DHCP, SMTP, HTTP, MODBUS/ TCP, AutoIP, NetBIOS-NS, Serial MODBUS GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 9021-60840 Rev. A page 2 of 2 www.gamewell-fci.com