AAD-8100 Intelligent FAAST Fire Alarm Aspiration Sensing Technology Description The Gamewell-FCI, Intelligent FAAST®, AAD-8100 Aspirating Smoke Detector combines dual source (blue LED and infrared laser), optical smoke detection with the fire alarm control panel connectivity, via the Velociti mode to provide high sensitivity to fire with intelligent reporting capabilities. In addition, the FAAST can provide enhanced immunity to a nuisance particulate. As a result, FAAST can deliver highly accurate Very Early Warning Fire Detection, directly over the Signaling Line Circuit (SLC) to a fire alarm control panel, via the Velociti protocol. This process enables maximum control over mission critical and challenging environments. Moreover, the FAAST can seamlessly integrate with an existing fire signaling circuit. The Intelligent FAAST Detector can be wired to a new or pre-existing SLC that is used for transmitting communications directly to a fire alarm control panel, via the Velociti mode, without using extra hardware. In the Velociti mode, the AAD-8100, FAAST will report back to the fire alarm control panel as an Aspirating detector. By setting the sensitivity levels in PipeIQ™, the fire alarm control panel will initiate pre-alarm and alarm conditions based on the feedback sent from the FAAST unit. Using the Velociti mode, up to 159 units can populate one SLC. For the initial system creation, FAAST’s design, configuration and monitoring software, PipeIQ, guide users through pipe layout. An installed device can be monitored through its integral display by any of the following ways: • from a computer connected to the device • remotely through a web browser When FAAST is connected to the Internet, it can also email status updates to the appropriate personnel. *A complimentary download of the PipeIQ software program is available at systemsensor.com/faast. AAD-8100 Features • • • • • • • • • • • • • Provides the SLC connectivity via the Velociti Protocol. Supports up to 159 FAAST devices per loop. Detection as precise as 0.00046%/ft obscuration. Includes five (5) alarm levels and two sensitivity modes provide application flexibility. Offers dual flow detection including both ultrasonic and electronic sensing for pipe and chamber air flow measurement. A single device protects up to 8,000 square feet. Applies advanced detection algorithms to reject common nuisance conditions. Uses a Patented particle separator and a field-replaceable filter to remove contaminants from the system. Employs PipeIQ™ software that provides an intuitive system layout, configuration, and monitoring all in one package. Has an on-board Ethernet interface that enables remote monitoring and e-mail status updates. Fault indicators exhibit a broad spectrum of events. Unique air flow pendulum graph verifies pipe network functionality. Particulate graph displays subtle environmental changes for early problem indications. SIGNALING PipeIQ™ and Acclimate™ are registered trademarks of Honeywell International Inc. ® FAAST is a registered trademark of System Sensor Inc. ® is a registered trademark of Underwriter’s Laboratories, Inc. UL S1913 7259-1703:0177 GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use. www.gamewell-fci.com 9021-60770 Rev. B page 1 of 2 ©2013 by Honeywell International Inc. All rights reserved. Specifications Intelligent FAAST Specifications Electrical Specifications External Supply Voltage 18-30 VDC Remote Reset Time External monitor must be pulled low for a minimum of 100 ms Power Reset 1 sec. Avg. Operating Current 500 mA @ 24 VDC Alarm 650 mA – All relays active, all alarm levels displayed. Voltage @ 24 VDC Average SLC Current 700uA SLC Voltage Range 15 to 32 VDC Relay Contact Ratings 3.0 A @ 30 VDC 0.5 A @ 125 VAC Environmental Ratings Operating Temperature Sampled Air Temperature Humidity Range IP Rating Coverage Area Air Movement 32°F (0°C) to 100°F (38°C) Figure 1 - Intelligent FAAST User Interface Display -4°F (-20°C) to 140°F (60°C) 10 to 95% (non-condensing) IP30 8,000 sq. ft. (800 sq. m) 0-4,000 ft./min. (0-1,219 m/min.) The User Interface consists of 5 Alarm levels: • Alert • Fire 1, 10 Particulate levels • Action 1 • Fire 2, 10 Bi-color Flow and Fault graph • Action 2 Physical Specifications Height Width Depth Cable Access Wire Gauge Maximum Single Pipe Length Maximum Branched (2) Pipe Length Maximum Air Inlet Holes Network Outside Pipe Diameter Internal Pipe Diameter Sensitivity Range Relays Event Log Communication Network Shipping Weight 13.25 inches (33.7 cm) 13.0 inches (33 cm) 5.0 inches (12.7 cm) 4 1-inch (2.54 cm) cable entry holes on top and bottom of unit 12 AWG (2.05 mm) max. to 24 AWG (0.5 mm) min. 262 ft. (80 m) 165 ft. (50 m) each branch 40 holes Ordering Information Part Number AAD-8100 Description System Sensor Intelligent FAAST Fire Alarm Aspiration Sensing Technology Accessories CMKT00100 FAAST Information Kit–Includes a Comprehensive Instruction Manual F-A3384-000 Replacement Air Filter Assembly Various† Language Card Various† UL®-Approved Pipe and Fittings † Additional accessory information, including part numbers, can be accessed at systemsensor.com/faast. 1.050 inches, IPS (25 mm) 0.591 to 0.827 inches (15-21 mm) 0.00046%Obs/ft to 6.25% Obs/ft (0.0015%Obs/m to 20.5%Obs/m) 6 form C, 3 AMP, programmable latching or non-latching 18,000 events stored Ethernet monitoring, 6 E-mail address alerts 11.6 lbs. (5.3 kg), includes packing material GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 9021-60770 Rev. B page 2 of 2 www.gamewell-fci.com