FAAST XT® AAD-9400X Intelligent Fire Alarm Aspiration Sensing Technology Description The Gamewell-FCI, Intelligent FAAST XT®, AAD-9400X aspirating smoke detectors deliver highly accurate Very Early Warning Fire Detection over a wide coverage area directly over the Signaling Line Circuit (SLC) to the fire alarm control panel via the Velociti protocol. This aspirating smoke detector combines advanced particle separation with a unique dual source optical smoke detection technology to provide highly sensitive Very Early Warning Fire Detection while providing enhanced immunity to false alarms. This technology enables FAAST to accurately detect incipient fire conditions as early as 60 minutes before a fire actually starts when set for Early Warning and Very Early Warning Fire Detection in applications ranging from mission critical to harsh and extreme environments. An installed FAAST XT device can protect up to 28,800 sq. ft. (2,676 sq. m) in the standard coverage type applications. The Intelligent FAAST XT Detector can be wired to a new or pre-existing SLC that is used for transmitting communications directly to a fire alarm control panel, via the Velociti mode, without using extra hardware. In the Velociti mode, the AAD-9400X, FAAST XT will report back to the fire alarm control panel as an aspirating detector. By setting the sensitivity levels in PipeIQ™, the fire alarm control panel will initiate pre-alarm and alarm conditions based on the feedback sent from the FAAST XT unit. Using the Velociti mode, up to 159 units can populate one SLC. In addition to providing a direct connection on the SLC, the FAAST XT device can be monitored in several different ways, including the following: • Serial or TCP Modbus® • Direct PC connection • Ethernet over a LAN • FAAST’s onboard USB When the AAD-9400X is connected to a LAN, the FAAST’s email server can email event notification to the appropriate personnel. FAAST also communicates alarm and fault conditions via Form C Relays. PipeIQ® is FAAST’s intuitive design, configuration, and monitoring software. The all-in-one program can be used to do the following: • Create a pipe network tailored to meet site specific requirements. • Configure a FAAST device. • Monitor an installed device including the following: - live trending - reading of historic reports *A complimentary download of PipeIQ is available at systemsensor.com/faast. Features AAD-9400X • Offers the SLC connectivity via the Velociti protocol. • Supports 159 FAAST XT devices per loop. • Provides Very Early Warning Fire Detection, as precise as 0.00046%/ft obscuration. • Includes five alarm levels and two sensitivity modes to provide application flexibility. • Has 3-fan speed settings that allow for maximum coverage area, and provide savings on current consumption. • Delivers ultrasonic flow sensing for each pipe inlet and chamber airflow monitoring for precise system health information. • A single device can cover up to 28,800 square feet. • Combines a dual source optical detection chamber with enhanced algorithms to provide high sensitivity with greater immunity to nuisance conditions. • Delivers a patented particle separator to remove large, non-fire particulate, ensuring chamber health and extending the life of the field-replaceable filter. • Converts TCP and Serial modbus for easy integration with building management systems. • Offers easy configuration via USB interface, no external power needed. • Supports an onboard Ethernet interface that enables remote monitoring and email notification. • Displays an LCD user interface that allows for detailed device information and interaction such as the following. - Active faults - Reset of airflow baseline - Test/reset/isolate - Precise airflow monitoring • Produces configurable air flow fault thresholds. PipeIQ® is a registered trademark of Honeywell International Inc. ® FAAST is a registered trademark of System Sensor Inc. Modbus® is a registered trademark of Modbus Organization UL® is a registered trademark of Underwriter’s Laboratories, Inc. SIGNALING S1913 GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use. www.gamewell-fci.com 9021-60838 Rev. A page 1 of 2 ©2014 by Honeywell International Inc. All rights reserved. Specifications Specifications (Continued) Intelligent FAAST XT Specifications Electrical Specifications Network Specifications (Continued) Webserver Read Configuration, Live View, Logs External Supply Voltage 18-30 VDC Remote Reset Time External monitor must be pulled low for a minimum of 100 ms Power Reset 1 sec. Avg. Operating Current Fan High - 465mA, 11.2W; Fan Med - 340mA, 8.2W; Fan Low - 220mA, 5.3W Alarm Fan High - 493mA, 11.85W; Fan Med - 368mA, 8.85W; Fan Low - 248mA, 6W Relay Contact Ratings 3.0 A @ 30 VDC, 0.5 A @ 125 VAC Configuration Specifications PipeQ USB or Ethernet Modbus Ethernet or RS-485 Figure 1 illustrates the FAAST XT user interface display. Environmental Ratings Operating Temperature 32°F (0°C) to 100°F (38°C); Factory Tested to 133°F (55°C) Sampled Air Temperature -4°F (-20°C) to 140°F (60°C) Humidity Range 10 to 95% (non-condensing) IP Rating IP30 Coverage Area 28,800 sq.ft. (2,676 sq.m) Air Movement 0-4,000 ft./min. (0-1,219 m/min.) Physical Specifications Height Width Depth Cable Access Wire Gauge Maximum Single Pipe Length Total Pipe Length 13.3 in (338 mm) 13.1 in (333 mm) 7.5 in (191 mm) 4 1-inch (2.54 cm) cable entry holes on top, bottom and back of the unit 12 AWG (2.05 mm) max. to 24 AWG (0.5 mm) min. 400 ft. (123 m) 1050 ft. (320 m) (*all designs must be verified within PipeIQ software) 262 ft. per pipe Figure 1 - Intelligent FAAST XT User Interface Display The User Interface consists of 5 Alarm levels: • Alert • Fire 1 and Fire 2, 10 Particulate levels • Action 1 and Flow and Fault graph • Action 2 Ordering Information Multiple Pipe Network Network Outside Pipe Diameter 1.050 inches, IPS (25 mm) Internal Pipe Diameter 0.591 to 0.827 inches (15-21 mm) Sensitivity Range 0.00046%Obs/ft to 6.25% Obs/ft (0.0015% Obs/m to 20.5% Obs/m) Relays 8 Form C, 3 AMP, programmable latching or non-latching Diagnostic Specifications Event Log 18,000 events stored Trend Data Log Configurable sampling period (1 minute to 1 day) Service Log 300 custom user entries Network Specifications Communication Ethernet monitoring Network 6 E-mail address alerts, TCP and Serial Modbus Network Services DHCP, SMTP, HTTP, MODBUS/ TCP, AutoIP, NetBIOS-NS, Serial MODBUS Ethernet 10/100Mbps, MDI-X Modbus TCP or Serial RSEmail 6 recipients, sel. notification Part Number AAD-9400X Description System Sensor Intelligent FAAST XT Fire Alarm Aspiration Sensing Technology Accessories CMKT00100 FAAST Information Kit–Includes a Comprehensive Instruction Manual F-A3384-000 Replacement Air Filter Assembly Various† UL®-Approved Pipe and Fittings † Additional accessory information, including part numbers, can be accessed at systemsensor.com/faast. GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 9021-60838 Rev. A page 2 of 2 www.gamewell-fci.com