FAAST XS Fire Alarm Aspiration Sensing Technology® FAAST XS aspirating smoke detectors deliver highly accurate Very Early Warning Fire Detection for the smaller applications and offer extensive communication capabilities. Features • Provides Very Early Warning Fire Detection, as precise as 0.00029%/ft obscuration • Three alarm levels and three sensitivity modes provide application flexibility • User configurable 3-speed fan, allowing for maximum coverage area or minimizing on current consumption • Ultrasonic flow sensing and chamber airflow monitoring for precise system health information The FAAST XS aspirating smoke detector combines advanced particle separation with unique dual source optical smoke detection technology to provide highly sensitive Very Early Warning Fire Detection while providing enhanced immunity to false alarms. This technology enables FAAST XS to accurately detect incipient fire conditions as early as 60 minutes before a fire actually starts when set for Early Warning and Very Early Warning Fire Detection in applications ranging from mission critical to harsh and extreme environments. • A single device covers up to 5,000 square feet (464 sq. m) • Dual source optical detection chamber with enhanced algorithms provide high sensitivity with greater immunity to nuisance conditions • Patented particle separator removes large, non-fire particulate, ensuring chamber health and extending the life of the fieldreplaceable filter • TCP and Serial modbus for easy integration with building management systems • Easy configuration via USB interface, no external power needed • Onboard Ethernet interface enables remote monitoring, configuration, web server and e-mail notifications • Multilingual LCD user interface allows for detailed device information and interaction such as: Active faults, precise airflow monitoring, reset of airflow baseline, test/reset/isolate, and more • Configurable air flow fault thresholds and verification period • Convenient wiring compartment • Status-at-a-glance provides immediate alarm, fault and airflow status Agency Listings S911 An installed FAAST XS device can protect up to 5,000 sq. ft. (464 sq. m) in standard coverage type applications and can be monitored in several different ways, including: Serial or TCP Modbus, Ethernet over a LAN or a direct connection, or via FAAST XS’s onboard USB. When connected to a LAN, FAAST XS’s email server can provide email event notification to appropriate personnel. FAAST XS also communicates alarm and notifications via form C relays. PipeIQ® is FAAST XS’s intuitive design, configuration, and monitoring software. The all-in-one program can be used to create a pipe network tailored to meet site specific requirements, configure a FAAST XS device, and monitor an installed device -- including live trending and reading of historic reports. *A complimentary download of PipeIQ is available at systemsensor.com/faast. FAAST XS Specifications Electrical Specifications External Supply Voltage Remote Reset Time Power Reset Operating Current Alarm Current Relay Contact Ratings 18-30 VDC External monitor must be pulled low for a minimum of 100 ms 1 sec. Fan High - 200mA, 4.8W; Fan Med - 151mA, 3.7W; Fan Low - 120mA, 2.1W Fan High - 230mA, 5.6W; Fan Med - 172mA, 4.2W; Fan Low - 142mA, 3.5W 3.0 A @ 30 VDC, 0.5 A @ 125 VAC 5 form C, 3 AMP, programmable latching or non-latching Operating Specifications Operating Temperature Sampled Air Temperature Humidity Range Sensitivity Range IP Rating Coverage Area Air Movement 32°F (0°C) to 100°F (38°C); Factory Tested to 131°F (55°C) -4°F (-20°C) to 140°F (60°C) 10 to 95% (non-condensing) 0.00029% Obs/ft to 6.25% Obs/ft (0.00095% Obs/m to 20.5% Obs/m) IP30 5,000 sq.ft. (464 sq.m) 0-4,000 ft./min. (0-1,219 m/min.) Physical Specifications Height Width Depth Cable Access Wire Gauge Maximum Single Pipe Length Total Aggregate Pipe Length Outside Pipe Diameter Internal Pipe Diameter Relays Diagnostic Specifications Event Log Trend Data Log Service Log Networking Specifications Communication Network Network Services Ethernet Modbus Email Webserver Configuration Specifications PipeIQ Modbus Ordering Information 11.0 in (279mm) 9.0 in (229mm) 6.25 in (159mm) 3 1-inch (2.54 cm) cable entry holes on top, and back of the unit 12 AWG (2.05 mm) max. to 24 AWG (0.5 mm) min. 180 ft. (54.9 m) *all designs must be verified within PipeIQ software 300 ft. (91.5m) *all designs must be verified within PipeIQ software 1.050 inches, IPS (25 mm) 0.591 to 0.827 inches (15-21 mm) 5 form C, 3 AMP, programmable latching or non-latching 18,000 events stored Configurable sampling period 1 minute to 1 day. 300 custom user entries Ethernet monitoring, 6 email address alerts, TCP and Serial Modbus DHCP, SMTP, HTTP, MODBUS/ TCP, AutoIP, NetBIOS-NS, Serial MODBUS 10/100Mbps, MDI-X TCP or Serial RS-485 6 recipients, selectable notifications Read Configuration, Live View, Logs USB or Ethernet Ethernet or RS-485 FAAST XS User Interface Display The User Interface consists of 3 Alarm levels – Alert, Fire 1, and Fire 2, 10 Particulate levels, 10 Airflow indicators, 4 Fault indicators, LCD. Part No. Description 7100X System Sensor Conventional FAAST Fire Alarm Aspiration Sensing Technology Accessories UL-Approved Pipe and Fittings Various† † Additional accessory information, including part numbers, can be accessed at systemsensor.com/faast 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax: 630-377-6495 www.systemsensor.com ©2015 System Sensor. Product specifications subject to change without notice. Visit systemsensor.com for current product information, including the latest version of this data sheet. ASDS78701 • 9/15