InnovairFlex™ Series Duct Smoke Detector Accessories

InnovairFlex™ Series
Duct Smoke
Detector Accessories
Notification and Test Accessories
Description
The InnovairFlex Series Duct Smoke Detector accessories
add functionality to the Duct Detection System. These
accessories are designed to provide quick and convenient,
accessibility for visual inspections and they offer effective
audible and visible notification options. All Gamewell-FCI
duct detectors and accessories are UL® Listed.
The following duct smoke detector accessories are
available.
• APA151
Piezo Annunciator
• MHR
Mini-Horn, Red
• MHW
Mini-Horn, White
• RA100Z/RA100ZA Remote Annunciator
• RTS151
Remote Test Station
• RTS151KEY
Remote Test Station with Key
• RTS2
Multi-Signaling Accessory
• AOS
Add-On Strobe
• RTS2-AOS
Multi-Signaling Accessory
InnovairFlex-Series Accessories
Features
The APA151 piezo annunciator replaces the APA451 with
a new and improved look. It provides the following:
• An audible alarm signal.
• A red LED to indicate alarm status.
• A green LED to indicate power status.
It is intended for use with the Gamewell-FCI 4-wire conventional duct smoke detector applications without a system control panel, to comply with NFPA 90A.
The MHR and MHW SpectrAlert® Advance mini-horns feature temporal or continuous tones that provide high and
low volume settings. Their small footprint allows mounting
to single-gang backboxes and are used for applications
where a small device is desired.
The RA100Z and RA100ZA remote annunciators are
designed for both conventional and intelligent applications.
The red LED provides visual indication of an alarm condition.
The RTS151 and RTS151KEY remote test stations are
automatic fire detector accessories designed to test duct
smoke detectors from a convenient location. For 4-wire
detectors, the RTS151KEY test station features a multicolored LED that alternates between steady green and
red. For 2-wire detectors, the LED illuminates red for
alarm.
• APA151 piezo annunciator offers a new style and provides enhanced audible alarm signals.
• MRH and MHW SpectrAlert Advance mini-horns feature
temporal and continuous tones for both high and low
volume settings.
• RA100Z and RA100ZA remote annunciators flexible
versatility are used for both conventional and intelligent
applications.
• RTS151 and RTS151KEY remote test stations are
designed to test duct detectors from remote locations.
• RTS2 and RTS2-AOS multi-signaling accessories are
used with the InnovairFlex 4-wire conventional duct
smoke detectors.
SIGNALING
®
InnovairFlex™and Sync•Circuit™ are trademarks and SpectraAlert is a registered trademark of Honeywell International Inc.
®
UL is a registered trademark of Underwriters Laboratories Inc.
FM
APPROVED
URRQ.S2522
7300-1653:0212
GAMEWELL-FCI
12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118
Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use.
www.gamewell-fci.com
9021-60532 Rev. B page 1 of 3
©2013 by Honeywell International Inc. All rights reserved.
Description (Continued)
Specifications, Duct Smoke Detector
Accessories (Continued)
The RTS2 and RTS2-AOS multi-signaling accessories are
designed to operate with the InnovairFlex 4-wire conventional duct smoke detectors. These accessories include a
key switch that can be used to select one of two connected
sensors to be tested, reset, or both by pressing a push
button switch. They also enable sensitivity measurements
using the SENS-RDR sensitivity reader (sold separately).
The AOS (Add-On Strobe) is an optional accessory
included with the RTS2-AOS model.
Specifications, Duct Smoke Detector
Accessories
APA151 Piezo Annunciator
Voltage:
Regulated 24 VDC
Operating Voltage:
16 to 33 VDC
Maximum Alarm Current: 30 mA
Temperature Range:
0°C to 49°C (32°F to 120°F)
Relative Humidity:
10 to 93% non-condensing
Wire Gauge:
12 to 18 AWG
Dimensions:
4.6” H × 2.9” W × .45” D
(11.6 H x 7.3 W x 1.1 D cm)
MHR/MHW SpectrAlert® Advance Mini-Horns
Voltage:
Regulated 12 DC or FWR
(Full Wave Rectified) or
Regulated 24 VDC or FWR
Operating Voltage:
8 to 33 VDC (9 to 33 VDC
with Sync•Circuit™ Module)
Sounder Current Draw:
22 mA RMS max.
at 8 to 17.5 Volts DC
17 mA RMS max.
at 8 to 17.5 Volts FWR
29 mA RMS max.
at 16 to 33 Volts DC
25 mA RMS max.
at 16 to 33 Volts FWR
Temperature Range:
0°C to 49°C (32°F to 120°F)
Humidity Range
10 to 93% non-condensing
Nominal Sounder
Frequency:
3 kHz
Wire Gauge:
12 to 18 AWG
Dimensions
4.6” H × 2.9” W × 0.45” D
(11.6 H x 7.3 W x 1.1 D cm)
RA100Z/RA100ZA Remote Annunciator
Voltage Range:
Conventional System: 3.1 to
32 VDC Intelligent System:
18 to 32 VDC
Maximum Alarm Current: 12 mA
Dimensions:
4.6” H × 2.8” W × 1.3” D
(11.6 H x 7.1 W x 3.3 D cm)
RTS151 Remote Test Station
Power Requirements:
Alarm LED: 2.8 to 32 VDC,
12 mA max.
Total Current: 105 mA max.
Test Switch:
10 VA @ 32 VDC
Reset Switch:
10 VA @ 32 VDC
Alarm Response Time:
40 seconds max.
Temperature Range:
–10°C to 60°C
(14°F to 140°F)
Relative Humidity:
95% non-condensing
Wire Gauge:
14 to 18 AWG
Dimensions:
4.8” H x 2.90” W x 1.4” D
(12.1 H x 7.3 W x 3.5 D cm)
RTS151KEY Remote Test Station with Key
Power Requirements:
Power LED (Green): 14 to
35 VDC, 12 mA max.
Alarm LED (Red): 2.8 to 32
VDC, 12 mA max.
Total Current: 105 mA max.
Alarm Response Time:
40 seconds max.
Temperature Range:
–10°C to 60°C
(14°F to 140°F)
Relative Humidity:
95% non-condensing
Wire Gauge:
14 to 18 AWG
Dimensions
4.6” H × 2.75” W × 1.8” D
(11.6 H x 6.9 W x 4.5 D cm)
RTS2 and RTS2-AOS Multi-signaling Accessory
Voltage:
20 to 29 VDC
Power Requirements:
Standby:
3.0 mA max.
Trouble:
16.0 mA max.
Alarm without strobe:
30 mA max.
Alarm with strobe:
55 mA max.
Sounder:
85 dBA at ten feet
Temperature Range:
–10°C to 60°C
(14°F to 140°F)
Relative Humidity:
95% non-condensing
Wire Gauge:
14 to 22 AWG
Dimensions:
4.8” W x 5.3” H x 1.6” D
(12.1 W x 13.4 H x 4.0 D cm)
For information on the most recent product specifications
and listing information, prefer to the Gamewell-FCI Web
site at www.gamewell-fci.com.
GAMEWELL-FCI
12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118
9021-60532 Rev. B page 2 of 3
www.gamewell-fci.com
Accessories
Gamewell-FCI provides system flexibility with a variety of accessories, including two remote test stations and several different
means of visible and audible system annunciation. As with our duct smoke detectors, all duct smoke detector accessories are UL
Listed.
Figure 1 RTS151 UL S2522
Figure 2 RTS151KEY UL S2522
Figure 3 APA151 UL S4011
Figure 4 RTS2-AOS UL S2522
Figure 5 RA100Z UL S2522
Figure 6 MHW UL S4011
Figure 7 MHR UL S4011
Figure 8 RTS2-AOS with PS24LOW
Strobe and PS12/24 LENSW lens
Ordering Information
Accessories
Part Number
Description
APA151
Piezo Annunciator
MHR
Mini Horn, Red
MHW
Mini Horn, White
RA100Z/RA100ZA Remote annunciator alarm LED
RTS151
Remote test station
Part Number
Description
RTS151KEY
RTS2
AOS
RTS2-AOS
Remote test station with key lock
Multi-signaling accessory
Add-On Strobe
Multi-signaling accessory
GAMEWELL-FCI
12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118
www.gamewell-fci.com
9021-60532 Rev. B page 3 of 3