05 Prem 2FA.qxd

Premises Cables
Fiber Optic
Tight Buffer Distribution Plenum Cable
Type OFNP, CSA FT-6
Product Construction:
Fiber:
• 2 - 96 fibers
• 900µm tight buffer
• Color coding per TIA/EIA 598B
Central Strength Member:
• Epoxy/Glass Rod (above 12 fibers)
Overall Strength Member:
• Aramid fiber yarn
Jacket:
• Flame-retardant polyvinyl chloride (PVC) or
fluoropolymer
• Sequential footage markings*
• Orange Jacket—Multimode fibers (except
10 Gb/s)
• Aqua Jacket—10 Gb/s Multimode fibers
• Yellow Jacket—Singlemode fibers
Features:
• Lightweight, flexible design simplifies installation
• Tight buffer provides individual fiber protection
• Tight buffered fibers are easy to handle and strip
for field connectorization
• Sub-units are numbered for identification
Performance:
• Temperature:
Storage -40˚C (-40˚F) to +70˚C (+158˚F)
Operating 0˚C (+32˚F) to +70˚C (+158˚F)
• Minimum Bend Radius:
20 X OD—Installation
10 X OD—In-Service
• Maximum Crush Resistance:
850 lbs/in (1485 N/cm)
• Maximum Vertical Rise—1,640 ft (500 m)
CATALOG
NUMBER
FIBER
COUNT
# OF
SUBUNITS
XX0021PNU
XX0041PNU
XX0061PNU
XX0081PNU
XX0121PNU
XX0181P1U
XX0241P1U
XX0361P1D
XX0481P1D
XX0601P1D
XX0721P1D
XX0961P1D
2
4
6
8
12
18
24
36
48
60
72
96
3
4
6
4
5
6
8
NOMINAL CABLE
DIAMETER
in
(mm)
.17
.18
.20
.21
.23
.50
.54
.61
.58
.67
.73
.86
(4)
(5)
(5)
(5)
(6)
(13)
(14)
(16)
(15)
(17)
(19)
(22)
NOMINAL CABLE
WEIGHT
lbs/1000' (kg/km)
12
14
16
18
23
110
118
151
135
186
217
312
(17)
(20)
(24)
(27)
(34)
(164)
(175)
(225)
(200)
(277)
(323)
(464)
MAXIMUM TENSILE LOAD
INSTALLATION
lbs
(N)
225
225
225
245
320
600
800
1000
1000
1000
1000
1500
(1000)
(1000)
(1000)
(1090)
(1423)
(2670)
(3560)
(4448)
(4448)
(4448)
(4448)
(6672)
IN-SERVICE
lbs
(N)
65
65
65
70
112
200
270
335
335
335
335
500
(290)
(290)
(290)
(311)
(500)
(890)
(1201)
(1490)
(1490)
(1490)
(1490)
(2224)
XX Denotes fiber type
Typical Cross-Section
Applications:
• Intrabuilding voice or data communication
backbones
• UL Listed Type OFNP for installation in
ducts, plenums and other spaces used as
environmental air returns when installed in
accordance with NEC article 770-51 (a) and
770-53 (a)
Flame-Retardant
Jacket
Flame-Retardant
Jacket
Overall
Strength Member
Overall
Strength Member
900µm Tight Buffer
Fiber
900µm Tight
Buffer Fiber
Compliances:
Sub-Unit
• UL and c(UL) Listed Type OFNP
• CSA FT-6
• ANSI/TIA/EIA 568B.3
• ICEA S-83-596
• ETL Verified
• GR-409
Central Strength
Member
4 Fiber
24 Fiber
Accessories:
• BOKP breakout kits are suitable for
Tight Buffer Distribution Plenum Cables
*Sequential meter markings available
upon request
RECOMMENDED FIBER TYPES
MIN. BANDWIDTH (Mhz•km)
DIMENSIONS (mm)
DESCRIPTION
G300
Super/50
Super
CORE
CLAD
COATING
850nm
1300nm
850/1300 nm
CG
BG
AP
62.5
50.0
8.3
125
125
125
245
245
245
220
500
–
500
500
–
3.5/1.0
3.0/1.0
–
Note: Additional fiber types available. Reference the Fiber Specification and Selection on page 2.
24
MAX. ATTENUATION (dB/km)
FIBER TYPE
1310/1550 nm
–
–
1.0/1.0