04 OutPlnt FA4.qxd

Fiber Optic
Outside Plant Cables
Loose Tube Single Jacket Cable
Product Construction:
Fiber:
• 2 - 288 fibers
• Loose tube gel-filled
• Color coding per TIA/EIA 598B
Central Strength Member:
• Epoxy/Glass Rod
CATALOG
NUMBER
# OF
FIBER LOOSE # OF
COUNT TUBES FILLERS
XX0023M1A-DWB
XX0044M1A-DWB
XX0064M1A-DWB
XX0084M1A-DWB
XX0124M1A-DWB
XX0184M1A-DWB
XX0244M1A-DWB
XX0364M1A-DWB
XX0484M1A-DWB
XX0604M1A-DWB
XX0724M1A-DWB
XX0964M1A-DWB
XX1204M1A-DWB
XX1444M1A-DWB
XX1924M1A-DWB
XX2164M1A-DWB
XX2404M1A-DWB
XX2644M1A-DWB
XX2884M1A-DWB
NOMINAL CABLE NOMINAL CABLE
DIAMETER
WEIGHT
in
(mm)
lbs/1000' (kg/km)
Overall Strength Member:
MAXIMUM TENSILE LOAD
INSTALLATION
lbs
(N)
IN-SERVICE
lbs
(N)
2
4
6
8
2
1
1
2
3
4
4
3
.36
.36
.36
.36
(9)
(9)
(9)
(9)
43
43
43
43
(64)
(64)
(64)
(64)
600
600
600
600
(2670)
(2670)
(2670)
(2670)
200
200
200
200
(890)
(890)
(890)
(890)
12
18
24
36
48
60
72
96
120
144
192
216
240
264
288
2
3
4
6
4
5
6
8
10
12
16
18
20
22
24
3
2
1
0
1
0
0
0
0
0
2
0
10
8
6
.36
.36
.36
.38
.41
.41
.44
.51
.57
.63
.64
.64
.83
.83
.83
(9)
(9)
(9)
(10)
(10)
(10)
(12)
(13)
(15)
(16)
(16)
(16)
(21)
(21)
(21)
44
44
45
49
55
55
62
75
99
120
118
118
197
197
197
(65)
(65)
(66)
(72)
(82)
(82)
(93)
(112)
(147)
(179)
(176)
(176)
(293)
(293)
(293)
600
600
600
600
600
600
600
600
600
600
600
600
600
600
600
(2670)
(2670)
(2670)
(2670)
(2670)
(2670)
(2670)
(2670)
(2670)
(2670)
(2670)
(2670)
(2670)
(2670)
(2670)
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200
(890)
(890)
(890)
(890)
(890)
(890)
(890)
(890)
(890)
(890)
(890)
(890)
(890)
(890)
(890)
• Aramid fiber yarn or fiberglass
Jacket:
• Black UV- and moisture-resistant polyethylene
(PE)
• Sequential footage markings*
Features:
• Loose tube gel-filled construction for superior
fiber protection
• UV- and moisture-resistant design
• Dry water block cable core for ease of handling
Performance:
• Temperature:
Storage -40˚C (-40˚F) to +70˚C (+158˚F)
Operating -40˚C (-40˚F) to +70˚C (+158˚F)
• Minimum Bend Radius:
20 X OD—Installation
10 X OD—In-Service
• Maximum Crush Resistance:
150 lbs/in (263 N/cm)
Applications:
• Interbuilding voice or data communication
backbones
• Installed in ducts, underground conduit or
aerial/lashed
Compliances:
• ANSI/TIA/EIA 568B.3
• ICEA S-87-640
• ETL Verified
• Rural Utilities Service (RUS) 7 CFR 1755.900
(REA PE-90)
• GR-20 Verified
XX Denotes fiber type
Typical Cross-Section
Accessories:
• SPK splitter kits are suitable for Loose Tube
Single Jacket Cables
PE Jacket
Overall Strength
Member
*Sequential meter markings available
upon request
Loose Tube
Fiber
Central Strength
Member
36 Fiber
Dry Water Block
Material
RECOMMENDED FIBER TYPES
MIN. BANDWIDTH (Mhz•km)
DIMENSIONS (µm)
DESCRIPTION
Premium
G300
MAX. ATTENUATION (dB/km)
FIBER TYPE
CORE
CLAD
COATING
850nm
1300nm
850/1300nm
AQ
CG
8.3
62.5
125
125
245
245
–
220
–
500
–
3.5/1.0
1310/1550nm
0.4/0.3
–
Note: Additional fiber types available. Reference the Fiber Specification and Selection on page 2.
13