Peltier Module Application Notes

Peltier Module Application Notes
Printing
Page 1/3
Print the heat-conducting silicon grease on the radiator and
Objective milled surface by cold-conducting piece to enhance the
heat-conducting efficiency
1. Preparing Work:
1) Use ethanol absolute tampon to rub up both
sides of cooling piece and installing sides of
radiator and cold-conducting piece;
Inspect radiator and milled surface by
cold-conducting piece and pick out pieces
with concaves and protruded or sunk
corners. Use blade to scrape possible burrs.
2) Position: adjust the position of
cold-conducting piece to face the center of
silk-screen plate with the center of
radiator and cold-conducting piece, and
fix the position frame.
Technical 2. Working Procedure:
1) Put the cold-conducting piece in the
position frame and close to the frame with
Procedure
the clean side facing upwards;
2) Paste the heat-conducting silicon grease on
the silk screen;
3) Put down the silk screen and use rubber
blade to scrap the heat-conducting silicon
grease on the silk-screen plate evenly and
smoothly;
4) Raise the silk screen to inspect the
evenness of heat-conducting silicon
grease.
5) Put the radiator into the position frame and
face it upwards;
6) Repeat the procedure 2-4.
Quality
Standard
Silicon grease shall be evenly pasted without foreign
substances and blank.
© Hebei IT Shanghai http://www.hebeiltd.com.cn
Peltier Module Application Notes
Installation
Objective
Page 2/3
Assemble the radiator, cooling piece, cooling piece shell and
the cold-conducting piece together
1. Install the cooling piece shell on the
cold-conducting piece and put the plane
side upwards;
Put the shell and cold-conducting piece
into the installation package;
Put the cooling piece into its shell and
close the side without down-lead to the
cold-conducting piece and the down-lead
shall be the same direction with the
opening of cooling piece. Note than the
large assembling hole of radiator shall be
Technical
directly face to the large screw plate and
the small assembling with the small screw
Procedure
plate of the shell;
2. Put the print face of radiator toward the
cooling piece on it and face the two
assembling holes of radiator to the
assembling holes of cold-conducting
piece;
3. Put screws into the assembling hole of
radiator;
4. Use pneumatic screwdriver to tighten
screws (not too tight) and connect the
radiator with cold-conducting piece.
1. Put the radiator downwards and the down-lead of cooling
Quality
Standard
piece shall face to operator with black line on the left and red
line on the right;
2. The cooling piece shall be installed with shell.
© Hebei IT Shanghai http://www.hebeiltd.com.cn
Peltier Module Application Notes
Page 3/3
Fixing
Objective
Connect radiator, cooling piece and cold-conducting piece together to
enhance the heat-conducting efficiency
1. Preparing Work:
1) Turn on the air-conditioning power and
adjust the pressure to 0.6 MP;
2) Adjust the screwdriver to torque of
15KgF·cm.
2. Working Procedure:
1) Put the components into the assembling
clamp and turn on the pneumatic switch.
The components shall be raised gradually
Technical
and the pressure of cooling piece shall be
10.5Kg/cm2 after clamping components;
Procedure 2) Use the screwdriver to tighten screws with
torque of 15KgF·cm;
3) Open assembling clamp and take off the
component, and check the product to
ensure the grounding protection of cooling
pieces between the cold-conducting piece
and the radiator.
4) Deliver the assembled products to QC
inspection
platform
for
performance
inspection.
Quality
Standard
The torques of both screws shall meet15KgF·cm.
© Hebei IT Shanghai http://www.hebeiltd.com.cn