Specification AXIOM125 Oscillator type: SMD OCXO with

Designed and
Manufactured
in Germany
Specification
Oscillator type:
Rev.: 2
AXIOM125
SMD OCXO with Sine Wave Output
Parameter
Frequency range
Standard frequencies
Frequency stability
Initial tolerance @ +25°C
vs. operating temperature range
vs. supply voltage variation (pushing)
vs. load change (pulling)
Long term (aging) per day
(after 30 days operation) (Note 2)
st
Long term (aging) 1 year
(after 30 days operation) (Note 2)
Frequency adjustment range
Electronic Frequency Control (EFC)
EFC voltage VC
EFC slope (∆f / ∆VC)
EFC input impedance
RF output
Signal waveform
Load RL
Output level (Note 3)
Harmonics
Warm-up time @ +25°C
Phase Noise
Supply voltage VS
Current consumption (steady state)
@ +25°C (Note 4)
Current consumption (warm-up)
(Note 4)
Enclosure (see drawing) (LxWxH)
Weight
Packing
Notes:
1.
2.
3.
4.
min.
typ.
max.
Unit
Date: 2014-04-18
Condition
10
125
MHz
10.000/20.000/80.000/100.000 MHz
±500
ppb
VC @ centre value
steady state
±10
±20
±10
±2
±500
±200
ppb
ppb
ppb
ppb
ppb
ppb
VS ±5%
RL ±10%
AT-Cut
SC-Cut
AT-Cut
SC-Cut
±5
ppm
ppm
V
V
AT-Cut
SC-Cut
Option 1 = “33”
Option 1 = “50”, “12”
Option 2 & 3
See tables 1 & 2
±300
±100
±2
±1
0.15
0.25
1.65
2.50
Positive
3.15
4.75
100
kΩ
Sine wave
50
+3
3.15
4.75
11.4
-25
2
Consult factory
3.3
3.45
5.0
5.25
12.0
12.6
300
200
100
700
500
200
22.7x15.1x11 max.
7
Ω
dBm
dBc
min
±10%
∆ffinal/f0 < ±0.1 ppm
V
V
V
mA
mA
mA
mA
mA
mA
Option 1 = “33”
Option 1 = “50”
Option 1 = “12”
Option 1 = “33”
Option 1 = “50”
Option 1 = “12”
Option 1 = “33”
Option 1 = “50”
Option 1 = “12”
mm
g
Palette or Tube
Terminology and test conditions are according to IEC60679-1 and MIL-PRF-55310, unless otherwise stated
Lower aging on request
Other output level on request
May be higher for wide operating temperature range
GmbH & Co. KG
Roemerring 9
D-74821 Mosbach
Germany
AXIOM125 Rev.2
Drawing D0
Page 1(4)
www.axtal.com
fon: +49 (6261) 939834
fax: +49 (6261) 939836
E-mail: [email protected]
Designed and
Manufactured
in Germany
Absolute Maximum Ratings
Parameter
min.
max.
Supply Voltage VS
Control Voltage VC
Storage Temperature
-0.5
-0.5
-55
VS + 10%
15
+125
Unit
Condition
V
V
°C
VS to GND
VC to GND
Frequency stability vs. temperature
Option 2
05
10
25
50
100
200
Table 1
Stability
[ppb]
±5
±10
±25
±50
±100
±200
Lower Temperature
Option 3
T [°C]
0
0
1
-10
2
-20
3
-30
4
-40
5
-55
Table 2
Upper Temperature
Option 3
T [°C]
A
+50
B
+60
C
+70
D
+75
E
+80
F
+85
Standard: “1B” = -10°C to +60°C
Temperature
Frequency stability [Option 2]
range [°C]
05
10
25
50
100
200
0 ~ +50
O
O
SC
AT
AT
AT
-10 ~ +60
O
O
SC
AT
AT
AT
-20 ~ +70
O
O
SC
SC
AT
AT
-30 ~ +70
O
O
SC
SC
SC
AT
-40 ~ +75
O
O
O
SC
SC
SC
-40 ~ +85
O
O
O
SC
SC
SC
-55 ~ +85
O
O
O
SC
SC
Table 3 “Availability” AT, SC = AT-Cut, SC-Cut available, O = available on request, - not available
Ordering Code
Option 1
Option 2
Option 3
[Supply Voltage] [Stability] [Temperature range]
AXIOM125
12, 33, 50
Table 1
Table 2
Example: AXIOM125-50-100-1B_Rev.2 – 10.000 MHz
Model
GmbH & Co. KG
Roemerring 9
D-74821 Mosbach
Germany
AXIOM125 Rev.2
Drawing D0
Page 2(4)
Revision
Frequency [MHz]
Rev.2
10.000
www.axtal.com
fon: +49 (6261) 939834
fax: +49 (6261) 939836
E-mail: [email protected]
Designed and
Manufactured
in Germany
Enclosure drawing
Pin connections
Pin #
1
7
8
14
Symbol
VC
GND
RF OUT
VS
Function
Control Voltage (EFC)
Ground
RF Output
Supply Voltage
* See Application Note AXAN-011
Handling and Testing
Parameter
Procedure
Handling and Testing
Processing
Parameter
Application Note AXAN-011
Application Note AXAN-012
Procedure
Electrostatic discharge (ESD)
THD devices
SMD devices
Washable
RoHS compliant
GmbH & Co. KG
Roemerring 9
D-74821 Mosbach
Germany
IEC60749-26
IEC60749-27
Yes
Yes
AXIOM125 Rev.2
Drawing D0
Page 3(4)
HBM
MM
No
No
Source
www.axtal.com
www.axtal.com
Condition
2000 V
200 V
www.axtal.com
fon: +49 (6261) 939834
fax: +49 (6261) 939836
E-mail: [email protected]
Designed and
Manufactured
in Germany
Environmental conditions
Test
Sealing tests
(if applicable)
Solderability
Resistance to
soldering heat
Shock*
IEC
60068
Part …
2-17
IEC
60679-1
Clause
5.6.2
MIL-STD202G
Method
112E
2-20
2-58
5.6.3
208H
210F
2-27
5.6.8
213B
MIL-STD810F
Method
MIL-PRF55310D
Clause
3.6.1.2
3.6.52
3.6.48
Vibration,
2-6
5.6.7.1
201A
sinusoidal*
204D
Vibration,
2-64
5.6.7.3
214A
random*
Endurance tests
108A
- ageing
5.7.1
- extended aging
5.7.2
Other environmental conditions on request
516.4
3.6.40
516.4-4
3.6.38.1
3.6.38.2
3.6.38.3
3.6.38.4
514.5
4.8.35
Test conditions (IEC)
Gross leak: Test Qc,
Fine leak: Test Qk
Test Ta Method 1
Test Td1 Method 2
Test Td2 Method 2
Test Ea, 3 x per axes 100g,
6 ms half-sine pulse
Test Fc, 30 min per axes,
10 Hz - 55 Hz 0,75mm; 55 Hz - 2 kHz, 10g
Test Fdb
30 days @ 85°C, OCXO @25°C
1000h, 2000h, 8000h @85°C
Data sheet is for information purposes only and may be subject to modifications or may be discontinued without notice.
Revision History
Rev.
Drawing
Date
[dd.mm.yyyy]
1
2
D0
D0
26.09.2012
15.04.2014
GmbH & Co. KG
Roemerring 9
D-74821 Mosbach
Germany
Remarks
First issue
Major revision
AXIOM125 Rev.2
Drawing D0
Page 4(4)
Author
Checked
BN
HH
BN
HH
www.axtal.com
fon: +49 (6261) 939834
fax: +49 (6261) 939836
E-mail: [email protected]