Designed and Manufactured in Germany Specification Oscillator type: Rev.: 1 Date: 2014-12-04 AXIOM175ULN Ultra-Low Phase Noise OCXO with Sine Wave Output Parameter Frequency Range Standard frequencies Frequency stability Initial tolerance @ +25°C vs. operating temperature range vs. supply voltage variation (pushing) vs. load change (pulling) Long term (aging) per day st Long term (aging) 1 year Frequency adjustment range Electronic Frequency Control (EFC) EFC voltage VC EFC slope (∆f / ∆VC) EFC input impedance RF output Signal waveform Load RL Output level (Note 2) Harmonics Spurious Warm-up time Phase noise @ 100 MHz and 120 MHz G-Sensitivity Reference voltage VREF output (Note 3) Supply voltage VS (Note 3) Current consumption (steady state) Current consumption (warm-up) Enclosure (see drawing) (LxWxH) (Note 5) Weight Packing Notes: 1. 2. 3. 4. 5. min. 80 typ. max. Unit Condition 125 100.000/120.000 MHz MHz ±300 Option 2 & 3 See tables 2 & 3 ±10 ±5 ±1 ±2 ±100 ±200 ppb VC @ VREF/2 steady state ppb ppb ppb ppb VS ±5% RL ±5% after 30 days operation after 30 days operation ±1 0 ±2 VREF/2 Positive VREF 100 kΩ Sine wave 50 Ω dBm dBc dBc min +7 3 See table 1 -30 -90 5 1.0 11.4 ppm V 10.0 12.0 ppb/g V V mA mA 12.6 150 350 27.8x27.8x15.5 max. 20 Palette ±5% ∆ffinal/f0 < ±0.1 ppm Option 1 per axis @ +25°C (Note 4) (Note 4) mm g Terminology and test conditions are according to IEC60679-1 and MIL-PRF-55310, unless otherwise stated Other output level on request Other supply and reference voltage on request May be higher for wide operating temperature range Lower height H available on request Absolute Maximum Ratings Parameter min. max. Supply Voltage VS Control Voltage VC Storage Temperature -0.5 -0.5 -55 VS + 10% 15 +125 GmbH & Co. KG Roemerring 9 D-74821 Mosbach Germany AXIOM175ULN Rev.1 Drawing D0 Page 1(4) Unit Condition V V °C VS to GND VC to GND www.axtal.com fon: +49 (6261) 939834 fax: +49 (6261) 939836 E-mail: [email protected] Designed and Manufactured in Germany Phase Noise – Option 1: Offset 10 Hz 100 Hz 1 kHz 10 kHz ≥100 kHz Table 1 A -90 -125 -155 -165 -175 B -95 -130 -158 -168 -175 100 MHz C -97 -132 -160 -170 -175 D -100 -135 -162 -172 -175 E -105 -137 -164 -174 -175 A -85 -118 -148 -160 -175 B -90 -122 -150 -165 -175 120 MHz C -95 -125 -153 -168 -175 D -97 -127 -155 -170 -175 E -100 -130 -157 -172 -175 Unit dBc/Hz dBc/Hz dBc/Hz dBc/Hz dBc/Hz Frequency stability vs. temperature Option 2 05 10 25 50 100 200 Table 2 Stability [ppb] ±5 ±10 ±25 ±50 ±100 ±200 Temperature range [°C] 05 0 ~ +50 O -10 ~ +60 O -20 ~ +70 O -30 ~ +70 O -40 ~ +75 -40 ~ +85 -55 ~ +85 Table 4 “Availability” Lower Temperature Option 3 T [°C] 0 0 1 -10 2 -20 3 -30 4 -40 5 -55 Table 3 10 X X X O O - Upper Temperature Option 3 T [°C] A +50 B +60 C +70 D +75 E +80 F +85 Standard: “1B” = -10°C to +60°C Frequency stability [Option 2] 25 50 100 X X X X X X X X X X X X X X X O X X O X X 200 X X X X X X X X = available, O = available on request, - not available Ordering Code Option 1 Option 2 Option 3 [Phase noise] [Stability] [Temperature range] AXIOM175ULN Table 1 Table 2 Table 3 Example: AXIOM175ULN-C-25-1B_Rev.1 – 100.000 MHz Model GmbH & Co. KG Roemerring 9 D-74821 Mosbach Germany AXIOM175ULN Rev.1 Drawing D0 Page 2(4) Revision Frequency [MHz] Rev.1 100.000 www.axtal.com fon: +49 (6261) 939834 fax: +49 (6261) 939836 E-mail: [email protected] Designed and Manufactured in Germany Enclosure drawing Pin connections Pin # 1 2 3 4 5 Symbol RF OUT GND VC VREF VS Function RF Output Ground Control Voltage (EFC) Reference voltage Supply Voltage * See Application Note AXAN-011 Handling and Testing Parameter Handling and Testing Processing Parameter Electrostatic discharge (ESD) THD devices SMD devices Washable RoHS- Compliant GmbH & Co. KG Roemerring 9 D-74821 Mosbach Germany Procedure Application Note AXAN-011 Application Note AXAN-012 Procedure IEC60749-26 IEC60749-27 Yes Yes AXIOM175ULN Rev.1 Drawing D0 Page 3(4) HBM MM No No Source www.axtal.com www.axtal.com Condition 2000 V 200 V www.axtal.com fon: +49 (6261) 939834 fax: +49 (6261) 939836 E-mail: [email protected] Designed and Manufactured in Germany Environmental conditions Test Sealing tests (if applicable) Solderability Resistance to soldering heat Shock* IEC 60068 Part … 2-17 IEC 60679-1 Clause 5.6.2 MIL-STD202G Method 112E 2-20 2-58 5.6.3 208H 210F 2-27 5.6.8 213B Vibration, 2-6 5.6.7.1 201A sinusoidal* 204D Vibration, 2-64 5.6.7.3 214A random* Endurance tests 108A - ageing 5.7.1 - extended aging 5.7.2 Other environmental conditions on request MIL-STD810F Method MIL-PRF55310D Clause 3.6.1.2 3.6.52 3.6.48 516.4 3.6.40 516.4-4 3.6.38.1 3.6.38.2 3.6.38.3 3.6.38.4 514.5 4.8.35 Test conditions (IEC) Gross leak: Test Qc, Fine leak: Test Qk Test Ta Method 1 Test Td1 Method 2 Test Td2 Method 2 Test Ea, 3 x per axes 100g, 6 ms half-sine pulse Test Fc, 30 min per axes, 10 Hz - 55 Hz 0,75mm; 55 Hz - 2 kHz, 10g Test Fdb 30 days @ 85°C, OCXO @25°C 1000h, 2000h, 8000h @85°C Data sheet is for information purposes only and may be subject to modifications or may be discontinued without notice. Revision History Rev. Drawing Date [dd.mm.yyyy] Remarks Author Checked 1 D0 04.12.2014 First issue HH HH GmbH & Co. KG Roemerring 9 D-74821 Mosbach Germany AXIOM175ULN Rev.1 Drawing D0 Page 4(4) www.axtal.com fon: +49 (6261) 939834 fax: +49 (6261) 939836 E-mail: [email protected]