Designed and Manufactured in Germany Specification Oscillator type: Rev.: 5 Date: 2014-07-09 AXIOM45 High Stability Eurocase OCXO with Sine Wave Output Parameter min. Frequency range Standard frequencies Frequency stability Initial tolerance @ +25°C vs. operating temperature range (steady state) 5 120 10.000 / 16.384 / 20.000 operating temperature range vs. supply voltage variation vs. load change Long term stability (aging) per year, after 30 days operation Frequency adjustment range Electronic Frequency Control (EFC) -10 EFC voltage VC EFC slope (∆f / ∆VC) EFC input impedance RF output Signal waveform Load Output amplitude Warm-up time @25°C Phase noise @ 10.000 MHz, Option II = „50“ Reference voltage VREF output (Note 3) Supply voltage VS typ. Enclosure (see drawing) LxWxH (Note4) Weight Packing Handling and Testing Processing GmbH & Co. KG Roemerring 9 D-74821 Mosbach Germany Unit Condition ±100 ±50 ±25 ±10 ±5 +60 ±2 ±2 ±200 ±100 MHz MHz ppm ppb ppb ppb ppb ppb ppb °C ppb ppb ppb ppb @ VC = 2.5V Option II = “100” Option II = “50” Option II = “25” Option II = “10” Option II = “5” Note 2 VS ± 5% 4.75 ppm ppm V ±500 ±0.8 ±1 0.25 ±1 Option II = “100” All other Options II 5 MHz to 12.8 MHz >12.8 MHz positive 100 kΩ Sine wave 50 +3 5 4.75 11.4 -120 -140 -145 -155 3.0 5.0 5.0 12.0 Current consumption (steady state) @ +25°C Current consumption (warm-up) Operable temperature range Storage temperature range max. -30 -40 5.25 12.6 200 100 500 250 +75 +85 Ω dBm min dBc dBc dBc dBc V V V V mA mA mA mA °C °C 36.1x27.2x19.4 max. mm 30 g Palette In accordance with AXAN-011 In accordance with AXAN-012 AXIOM45 Rev.5 Drawing D1 Page 1(3) (Note 5) ∆ffinal/f0 < ±0.1 ppm @ 10 Hz @ 100 Hz @ 1 kHz @ 10 kHz Option I =“50“ Option I =“12“ Option I =“50“ Option I =“12“ Option I =“50“ Option I =“12“ IEC 60679-3 CO 08 www.axtal.com www.axtal.com www.axtal.com fon: +49 (6261) 939834 fax: +49 (6261) 939836 E-mail: [email protected] Designed and Manufactured in Germany Notes: 1. 2. 3. 4. 5. Terminology and test conditions are according to IEC standard IEC60679-1, unless otherwise stated Other operating temperature ranges on request Other reference voltages on request Lower height H available on request Higher output level on request Ordering Code: Model (Specification) AXIOM45 Option I 50 Option II 100 Revision Rev.5 Frequency [MHz] 10.000 Enclosure: Pin connections Pin # 1 2 3 4 5 Symbol VC VREF VS RF OUT GND Function Control Voltage (EFC) Reference Voltage Supply Voltage RF Output Ground Environmental conditions Test Sealing tests (if applicable) Solderability Resistance to soldering heat Shock* IEC 60068 Part ... 2-17 IEC 60679-1 clause ... 4.6.2 2-20 2-58 4.6.3 2-27 4.6.8 Vibration, sinusoidal* 2-6 4.6.7 Endurance tests - ageing 4.7.1 - extended aging 4.7.2 Other environmental conditions on request GmbH & Co. KG Roemerring 9 D-74821 Mosbach Germany Test conditions Gross leak: Test Qc, Fine leak: Test Qk Test Ta (235 ± 5)°C Method 1 Test Tb Method 1A, 5s Test Ea, 3 x per axes 100g, 6 ms half-sine pulse Test Fc, 30 min per axes, 10 Hz - 55 Hz 0,75mm; 55 Hz - 2 kHz, 10g 30 days @ 85°C, OCXO @25°C 1000h, 2000h, 8000h @85°C AXIOM45 Rev.5 Drawing D1 Page 2(3) www.axtal.com fon: +49 (6261) 939834 fax: +49 (6261) 939836 E-mail: [email protected] Designed and Manufactured in Germany Revision History Rev. Drawing Date [dd.mm.yyyy] 5 5 D0 D1 01.03.2010 09.07.2014 GmbH & Co. KG Roemerring 9 D-74821 Mosbach Germany Remarks EFC range changed Editorial changes AXIOM45 Rev.5 Drawing D1 Page 3(3) Author Checked BN HH BN HH www.axtal.com fon: +49 (6261) 939834 fax: +49 (6261) 939836 E-mail: [email protected]