AXIOM45-12-10_Rev5-93.3333MHz

Designed and
Manufactured
in Germany
Specification
Oscillator type:
Rev.: 5
Date: 2014-07-09
AXIOM45
High Stability Eurocase OCXO with Sine Wave Output
Parameter
min.
Frequency range
Standard frequencies
Frequency stability
Initial tolerance @ +25°C
vs. operating temperature range
(steady state)
5
120
10.000 / 16.384 / 20.000
operating temperature range
vs. supply voltage variation
vs. load change
Long term stability (aging) per year,
after 30 days operation
Frequency adjustment range
Electronic Frequency Control (EFC)
-10
EFC voltage VC
EFC slope (∆f / ∆VC)
EFC input impedance
RF output
Signal waveform
Load
Output amplitude
Warm-up time @25°C
Phase noise
@ 10.000 MHz, Option II = „50“
Reference voltage VREF output
(Note 3)
Supply voltage VS
typ.
Enclosure (see drawing) LxWxH (Note4)
Weight
Packing
Handling and Testing
Processing
GmbH & Co. KG
Roemerring 9
D-74821 Mosbach
Germany
Unit
Condition
±100
±50
±25
±10
±5
+60
±2
±2
±200
±100
MHz
MHz
ppm
ppb
ppb
ppb
ppb
ppb
ppb
°C
ppb
ppb
ppb
ppb
@ VC = 2.5V
Option II = “100”
Option II = “50”
Option II = “25”
Option II = “10”
Option II = “5”
Note 2
VS ± 5%
4.75
ppm
ppm
V
±500
±0.8
±1
0.25
±1
Option II = “100”
All other Options II
5 MHz to 12.8 MHz
>12.8 MHz
positive
100
kΩ
Sine wave
50
+3
5
4.75
11.4
-120
-140
-145
-155
3.0
5.0
5.0
12.0
Current consumption (steady state)
@ +25°C
Current consumption (warm-up)
Operable temperature range
Storage temperature range
max.
-30
-40
5.25
12.6
200
100
500
250
+75
+85
Ω
dBm
min
dBc
dBc
dBc
dBc
V
V
V
V
mA
mA
mA
mA
°C
°C
36.1x27.2x19.4 max.
mm
30
g
Palette
In accordance with AXAN-011
In accordance with AXAN-012
AXIOM45 Rev.5
Drawing D1
Page 1(3)
(Note 5)
∆ffinal/f0 < ±0.1 ppm
@ 10 Hz
@ 100 Hz
@ 1 kHz
@ 10 kHz
Option I =“50“
Option I =“12“
Option I =“50“
Option I =“12“
Option I =“50“
Option I =“12“
IEC 60679-3 CO 08
www.axtal.com
www.axtal.com
www.axtal.com
fon: +49 (6261) 939834
fax: +49 (6261) 939836
E-mail: [email protected]
Designed and
Manufactured
in Germany
Notes:
1.
2.
3.
4.
5.
Terminology and test conditions are according to IEC standard IEC60679-1, unless otherwise stated
Other operating temperature ranges on request
Other reference voltages on request
Lower height H available on request
Higher output level on request
Ordering Code:
Model (Specification)
AXIOM45
Option I
50
Option II
100
Revision
Rev.5
Frequency [MHz]
10.000
Enclosure:
Pin connections
Pin #
1
2
3
4
5
Symbol
VC
VREF
VS
RF OUT
GND
Function
Control Voltage (EFC)
Reference Voltage
Supply Voltage
RF Output
Ground
Environmental conditions
Test
Sealing tests
(if applicable)
Solderability
Resistance to
soldering heat
Shock*
IEC 60068
Part ...
2-17
IEC 60679-1
clause ...
4.6.2
2-20
2-58
4.6.3
2-27
4.6.8
Vibration, sinusoidal* 2-6
4.6.7
Endurance tests
- ageing
4.7.1
- extended aging
4.7.2
Other environmental conditions on request
GmbH & Co. KG
Roemerring 9
D-74821 Mosbach
Germany
Test conditions
Gross leak: Test Qc,
Fine leak: Test Qk
Test Ta (235 ± 5)°C Method 1
Test Tb Method 1A, 5s
Test Ea, 3 x per axes 100g, 6 ms
half-sine pulse
Test Fc, 30 min per axes,
10 Hz - 55 Hz 0,75mm; 55 Hz - 2
kHz, 10g
30 days @ 85°C, OCXO @25°C
1000h, 2000h, 8000h @85°C
AXIOM45 Rev.5
Drawing D1
Page 2(3)
www.axtal.com
fon: +49 (6261) 939834
fax: +49 (6261) 939836
E-mail: [email protected]
Designed and
Manufactured
in Germany
Revision History
Rev.
Drawing
Date
[dd.mm.yyyy]
5
5
D0
D1
01.03.2010
09.07.2014
GmbH & Co. KG
Roemerring 9
D-74821 Mosbach
Germany
Remarks
EFC range changed
Editorial changes
AXIOM45 Rev.5
Drawing D1
Page 3(3)
Author
Checked
BN
HH
BN
HH
www.axtal.com
fon: +49 (6261) 939834
fax: +49 (6261) 939836
E-mail: [email protected]