AXIOM75-12-xx_Rev4-100.000MHz

Designed and
Manufactured
in Germany
Specification
Oscillator type:
Rev.: 4
Date: 2014-07-08
AXIOM75
Low Phase Noise OCXO with Sine Wave Output
Parameter
min.
max.
Unit
Frequency Range
Standard frequencies
Frequency stability
Initial tolerance at delivery
vs. operating temperature range
(steady state)
10
125
10.000 / 12.800 / 100.000
MHz
± 500
± 200
± 100
± 50
± 25
± 10
+60
± 10
±5
± 10
±2
± 200
± 100
ppb
ppb
ppb
ppb
ppb
ppb
°C
ppb
ppb
ppb
ppb
ppb
ppb
@+25°C @VC = VREF/2
Option II = “200”
Option II = “100”
Option II = “50”
Option II = “25”
Option II = “10”
(Note 2)
VS ±5%
RL ±5%
Option II=“200”, “100”
Option II=“50”,“25”,”10”
Option II=“200”, “100”
Option II=“50”,“25”,”10”
Option II= “200”, “100”
Option II=“50”,“25”,”10”
VREF
ppm
ppm
V
operating temperature range
vs. supply voltage variation
vs. load change
Long term (aging) per day,
after 30 days operation
st
Long term (aging) 1 year,
after 30 days operation
Frequency adjustment range
Electronic Frequency Control (EFC)
EFC voltage VC
EFC slope (∆f / ∆VC)
EFC input impedance
RF output
Signal waveform
Output level
Harmonics
Spurious
Warm-up time
Phase noise
Reference voltage VREF output
(Note 3)
Supply voltage VS
-10
±5
±1
±3
± 0.8
0
Enclosure (see drawing) (LxWxH)
Weight
Handling and Testing
Processing
Notes:
1.
2.
3.
±1
Condition
positive
100
kΩ
Sine wave
+7
4.75
11.4
Current consumption (steady state)
@ +25°C
Current consumption (warm-up)
Operable temperature range
Storage temperature range
typ.
-20
-40
RL = 50 Ω
dBm
dBc
dBc
min
-30
-90
5
Please consult factory
4.0
V
10.0
V
5.0
5.25
V
12
12.6
V
250
mA
100
mA
600
mA
250
mA
+70
°C
+85
°C
25.8x25.8x12.7max.
mm
10
g
In accordance with AXAN-011
In accordance with AXAN-012
∆ffinal/f0 < ±0.1 ppm
Option I = “50”
Option I = “12”
Option I = “50”
Option I = “12”
Option I = “50”
Option I = “12”
Option I = “50”
Option I = “12”
www.axtal.com
www.axtal.com
Terminology and test conditions are according to IEC standard IEC60679-1, unless otherwise stated
Other operating temperature range on request
Other reference voltage on request
GmbH & Co. KG
Roemerring 9
D-74821 Mosbach
Germany
AXIOM75 Rev.4
Drawing D1
Page 1(2)
www.axtal.com
fon: +49 (6261) 939834
fax: +49 (6261) 939836
E-mail: [email protected]
Designed and
Manufactured
in Germany
Ordering Part Number Code:
Model (Specification)
AXIOM75
Revision Option I
Rev.4
12
Option II
25
Frequency [MHz]
10.000
Enclosure drawing
Pin connections
Pin #
1
2
3
4
5
Symbol
RF OUT
GND
VC
VREF
VS
Function
RF Output
Ground
Control Voltage (EFC)
Reference Voltage
Supply Voltage
Environmental conditions
Test
Sealing tests
(if applicable)
Solderability
Resistance to
soldering heat
Shock*
IEC 60068
Part ...
2-17
IEC 60679-1
clause ...
4.6.2
2-20
2-58
4.6.3
2-27
4.6.8
Test conditions
Gross leak: Test Qc,
Fine leak: Test Qk
Test Ta (235 ± 5)°C Method 1
Test Tb Method 1A, 5s
Vibration, sinusoidal* 2-6
4.6.7
Test Ea, 3 x per axes 100g, 6 ms
half-sine pulse
Test Fc, 30 min per axes,
10 Hz - 55 Hz 0,75mm; 55 Hz - 2
kHz, 10g
Endurance tests
- ageing
- extended aging
4.7.1
4.7.2
30 days @ 85°C, OCXO @25°C
1000h, 2000h, 8000h @85°C
Revision History
Rev.
Drawing
Date
[dd.mm.yyyy]
4
4
D0
D1
09.01.2013
08.07.2014
GmbH & Co. KG
Roemerring 9
D-74821 Mosbach
Germany
Remarks
Tuning and reference voltages changed
Editorial changes
AXIOM75 Rev.4
Drawing D1
Page 2(2)
Author
Checked
BN
HH
BN
HH
www.axtal.com
fon: +49 (6261) 939834
fax: +49 (6261) 939836
E-mail: [email protected]