Designed and Manufactured in Germany Specification Oscillator type: Rev.: 4 Date: 2014-07-08 AXIOM75 Low Phase Noise OCXO with Sine Wave Output Parameter min. max. Unit Frequency Range Standard frequencies Frequency stability Initial tolerance at delivery vs. operating temperature range (steady state) 10 125 10.000 / 12.800 / 100.000 MHz ± 500 ± 200 ± 100 ± 50 ± 25 ± 10 +60 ± 10 ±5 ± 10 ±2 ± 200 ± 100 ppb ppb ppb ppb ppb ppb °C ppb ppb ppb ppb ppb ppb @+25°C @VC = VREF/2 Option II = “200” Option II = “100” Option II = “50” Option II = “25” Option II = “10” (Note 2) VS ±5% RL ±5% Option II=“200”, “100” Option II=“50”,“25”,”10” Option II=“200”, “100” Option II=“50”,“25”,”10” Option II= “200”, “100” Option II=“50”,“25”,”10” VREF ppm ppm V operating temperature range vs. supply voltage variation vs. load change Long term (aging) per day, after 30 days operation st Long term (aging) 1 year, after 30 days operation Frequency adjustment range Electronic Frequency Control (EFC) EFC voltage VC EFC slope (∆f / ∆VC) EFC input impedance RF output Signal waveform Output level Harmonics Spurious Warm-up time Phase noise Reference voltage VREF output (Note 3) Supply voltage VS -10 ±5 ±1 ±3 ± 0.8 0 Enclosure (see drawing) (LxWxH) Weight Handling and Testing Processing Notes: 1. 2. 3. ±1 Condition positive 100 kΩ Sine wave +7 4.75 11.4 Current consumption (steady state) @ +25°C Current consumption (warm-up) Operable temperature range Storage temperature range typ. -20 -40 RL = 50 Ω dBm dBc dBc min -30 -90 5 Please consult factory 4.0 V 10.0 V 5.0 5.25 V 12 12.6 V 250 mA 100 mA 600 mA 250 mA +70 °C +85 °C 25.8x25.8x12.7max. mm 10 g In accordance with AXAN-011 In accordance with AXAN-012 ∆ffinal/f0 < ±0.1 ppm Option I = “50” Option I = “12” Option I = “50” Option I = “12” Option I = “50” Option I = “12” Option I = “50” Option I = “12” www.axtal.com www.axtal.com Terminology and test conditions are according to IEC standard IEC60679-1, unless otherwise stated Other operating temperature range on request Other reference voltage on request GmbH & Co. KG Roemerring 9 D-74821 Mosbach Germany AXIOM75 Rev.4 Drawing D1 Page 1(2) www.axtal.com fon: +49 (6261) 939834 fax: +49 (6261) 939836 E-mail: [email protected] Designed and Manufactured in Germany Ordering Part Number Code: Model (Specification) AXIOM75 Revision Option I Rev.4 12 Option II 25 Frequency [MHz] 10.000 Enclosure drawing Pin connections Pin # 1 2 3 4 5 Symbol RF OUT GND VC VREF VS Function RF Output Ground Control Voltage (EFC) Reference Voltage Supply Voltage Environmental conditions Test Sealing tests (if applicable) Solderability Resistance to soldering heat Shock* IEC 60068 Part ... 2-17 IEC 60679-1 clause ... 4.6.2 2-20 2-58 4.6.3 2-27 4.6.8 Test conditions Gross leak: Test Qc, Fine leak: Test Qk Test Ta (235 ± 5)°C Method 1 Test Tb Method 1A, 5s Vibration, sinusoidal* 2-6 4.6.7 Test Ea, 3 x per axes 100g, 6 ms half-sine pulse Test Fc, 30 min per axes, 10 Hz - 55 Hz 0,75mm; 55 Hz - 2 kHz, 10g Endurance tests - ageing - extended aging 4.7.1 4.7.2 30 days @ 85°C, OCXO @25°C 1000h, 2000h, 8000h @85°C Revision History Rev. Drawing Date [dd.mm.yyyy] 4 4 D0 D1 09.01.2013 08.07.2014 GmbH & Co. KG Roemerring 9 D-74821 Mosbach Germany Remarks Tuning and reference voltages changed Editorial changes AXIOM75 Rev.4 Drawing D1 Page 2(2) Author Checked BN HH BN HH www.axtal.com fon: +49 (6261) 939834 fax: +49 (6261) 939836 E-mail: [email protected]