Z04

Z04
4 A Triacs
Main features
TO202-3
Symbol
Value
Unit
IT(RMS)
4
A
VDRM/VRRM
600 to 800
V
IGT (Q1)
3 to 25
mA
Order codes
Part Number
Marking
Z04xxyF(1)
Z04xxyF(1)
1. xx = sensitivity, y = voltage
Description
A2
The Z04 series is suitable for general purpose AC
switching applications. They can be found in
applications such as home appliances
(electrovalve, pump, door lock, small lamp
control), fan speed controllers,...
G
A1
Different gate current sensitivities are available,
allowing optimized performances when controlled
directly from microcontrollers.
Table 1.
Absolute maximum ratings
Symbol
IT(RMS)
ITSM
I ²t
Parameter
Tamb = 25° C
RMS on-state current (full sine wave)
Value
Unit
4
A
Tl = 30° C
Non repetitive surge peak on-state current
(full cycle, Tj initial = 25° C)
F = 50 Hz
t = 20 ms
20
F = 60 Hz
t = 16.7 ms
21
I²t Value for fusing
tp = 10 ms
A
2.2
A ²s
dI/dt
Critical rate of rise of on-state current IG =
F = 120 Hz
2 x IGT , tr ≤ 100 ns
Tj = 125° C
20
A/µs
IGM
Peak gate current
Tj = 125° C
1.2
A
Tj = 125° C
0.2
W
- 40 to + 150
- 40 to + 125
°C
PG(AV)
Tstg
Tj
2015-6-15
tp = 20 µs
Average gate power dissipation
Storage junction temperature range
Operating junction temperature range
1
www,kersemi.com
8
Z04
1
Characteristics
Table 2.
Electrical Characteristics (Tj = 25° C, unless otherwise specified)
Z04
Symbol
Test Conditions
Quadrant
IGT (1)
VGD
VD = VDRM RL = 3.3 kΩ
Tj = 125° C
IH (2)
IT = 50 mA
IL
IG = 1.2 IGT
(dV/dt)c (2)
09
10
3
5
10
25
MAX
.
ALL
MAX
.
1.3
V
ALL
MIN.
0.2
V
MAX
.
I - III - IV
dV/dt (2)
05
I - II - III - IV
VD = 12 V RL = 30 Ω
VGT
Unit
02
3
5
10
25
mA
mA
MAX
.
6
10
15
25
12
15
25
50
VD = 6 % VDRM gate open Tj = 110° C
MIN.
10
20
100
200
V/µs
(dI/dt)c = 1.8 A/ms
MIN.
0.5
1
2
5
V/µs
II
Tj = 110° C
mA
1. minimum IGT is guaranted at 5% of IGT max.
2. for both polarities of A2 referenced to A1.
Table 3.
Static Characteristics
Symbol
Test Conditions
VTM (1)
ITM = 5.5 A
Vto (1)
Rd
(1)
IDRM
IRRM
tp = 380 µs
Value
Unit
Tj = 25° C
MAX.
2.0
V
Threshold voltage
Tj = 125° C
MAX.
0.95
V
Dynamic resistance
Tj = 125° C
MAX.
180
mΩ
5
µA
0.5
mA
Tj = 25° C
VDRM = VRRM
Tj = 125° C
MAX.
1. for both polarities of A2 referenced to A1.
Table 4.
Thermal resistances
Symbol
2015-6-15
Parameter
Value
Unit
Rth(j-I)
Junction to lead (AC)
15
° C/W
Rth(j-a)
Junction to ambient
100
° C/W
2
www,kersemi.com
8
Z04
Figure 1.
Maximum power dissipation
versus RMS on-state current
(full cycle)
Figure 2.
P(W)
RMS on-state current versus
ambient temperature (full cycle)
IT(RMS)(A)
7
4.5
Rth(j-a) = Rth(j-l)
4.0
6
3.5
5
3.0
4
2.5
3
2.0
1.5
Rth(j-a) = 100°C/W
2
1.0
1
0.5
IT(RMS)(A)
Tamb (°C)
0.0
0
0.0
0.5
1.0
Figure 3.
1.5
2.0
2.5
3.0
3.5
0
4.0
Relative variation of thermal
impedance versus pulse
duration
25
Figure 4.
50
75
100
125
Relative variation of gate trigger
current, holding current and
latching current versus junction
temperature (typical values)
IGT, IH, IL [Tj] / IGT, IH, IL [Tj=25°C]
K=[Zth(j-a)/Rth(j-a)]
2.5
1E+0
2.0
1E-1
1.5
IGT
IH & IL
1.0
1E-2
0.5
Tj (°C)
tp(s)
1E-3
0.0
1E-3
1E-2
Figure 5.
1E-1
1E+0
1E+1
1E+2
5E+2
Surge peak on-state current
versus number of cycles
-40
-20
Figure 6.
0
20
40
60
80
100
120
140
Non-repetitive surge peak on-state
current for a sinusoidal pulse with
width tp < 10 ms and corresponding
value of I2t
ITSM (A), I2t (A2s)
ITSM (A)
25
500
Tj initial = 25°C
t=20ms
20
100
One cycle
dI/dt limitation:
20A/µs
15
ITSM
Non repetitive
Tj initial = 25°C
10
Repetitive
Tamb = 25°C
10
5
I2t
0
1
2015-6-15
tp (ms)
Number of cycles
10
100
1
0.01
1000
3
0.10
1.00
10.00
www,kersemi.com
8
Z04
Figure 7.
On-state characteristics
(maximum values)
Figure 8.
ITM(A)
(dI/dt)c [(dV/dt)c] / Specified (dI/dt)c
20.0
2.6
2.4
2.2
2.0
1.8
1.6
1.4
1.2
1.0
0.8
0.6
0.4
0.2
0.0
10.0
Tj = Tjmax.
1.0
Tj = 25°C
Tj=max.
Vt0=0.95 V
Rd=180 mΩ
VTM (V)
0.1
0.0
Figure 9.
Relative variation of critical rate of
decrease of main current versus
(dV/dt)c (typical values)
0.5
1.0
1.5
2.0
2.5
3.0
3.5
4.0
4.5
Z0410
Z0409
Z0402
Z0405
(dV/dt)c (V/µs)
0.1
5.0
1.0
10.0
100.0
Relative variation of critical
rate of decrease of main current
versus junction temperature
(dI/dt)c [Tj] / (dI/dt)c [Tj Specified]
6
5
4
3
2
1
Tj (°C)
0
2015-6-15
0
25
50
75
100
125
4
www,kersemi.com
8
Z04
2
Ordering information scheme
Z 04 xx y F
[BLANK]
0AA2
Triac series
Current
04 = 4A
Sensitivity
02 = 3mA
05 = 5mA
09 = 10mA
10 = 25mA
Voltage
M = 600V
S = 700V
N = 800V
Package
F = TO202-3
Packing mode
0AA2 = Tube
Table 5.
Product selector
Voltage
Part Number
Sensitivity
Type
Package
Standard
TO202-3
600 V 700 V 800 V
Z0402MF
X
Z0402SF
3 mA
X
Z0402NF
Z0405MF
X
X
Z0405SF
X
X
Z0410SF
X
10 mA
X
X
10 mA
25 mA
X
Z0410NF
2015-6-15
5 mA
10 mA
Z0409NF
Z0410MF
5 mA
X
Z0409SF
3 mA
5 mA
Z0405NF
Z0409MF
3 mA
25 mA
X
5
25 mA
www,kersemi.com
Z04
3
Package information
DIMENSIONS
REF.
Millimeters
Min.
Typ.
A
A
C
F
D
J
P
H
N1
N
Typ.
7.3
0.287
D
10.5
0.413
1.5
0.059
H
0.51
0.020
J
1.5
0.059
M
4.5
0.177
N1
5.3
2.54
Max.
0.398
C
N
M
Min.
10.1
F
O
Max.
Inches
0.209
0.100
O
1.4
0.055
P
0.7
0.028
In order to meet environmental requirements, ST offers these devices in ECOPACK®
packages. These packages have a lead-free second level interconnect. The category of
second level interconnect is marked on the package and on the inner box label, in
compliance with JEDEC Standard JESD97. The maximum ratings related to soldering
conditions are also marked on the inner box label. ECOPACK is an ST trademark.
ECOPACK specifications are available at: www.st.com.
2015-6-15
6
www,kersemi.com
Z04
4
Ordering information
Ordering type
Marking
Weight
Base qty
Delivery mode
Z04xxyF 0AA2(1)
Z04xxyF(1)
0.8 g
50
Tube
1. xx = sensitivity, y = voltage
5
2015-6-15
Revision history
Date
Revision
Description of Changes
Oct-2001
4
Last update.
13-Feb-2006
5
TO202-3 delivery mode changed from bulk to tube.
ECOPACK statement added.
31-Mar-2006
6
Reformatted to current standard. Lead marking changed
on page 1
12-05-2006
7
Typographical error for (dV/dt)c corrected in Table 2.
7
www,kersemi.com