Cypress Semiconductor Corporation 198 Champion Court San Jose, CA 95134 February 09, 2011 Dear Cypress Customer. This is to declare that the test results summarized on the attached report are valid for 5 years from the report date. In other words, the data reported shall remain the same until February 09, 2016. Should there by any changes in the RoHS compliance status of the material mentioned in the report prior to this date, Cypress will re-conduct testing and post an updated copy of the report with the latest results. In the absence of any changes during the 5 year validity period, the original test results can be leveraged for RoHS compliance purposes. Customers will be notified to changes in form, fit or function (e.g., assembly material set or location) via Cypress’s Product Change Notice (PCN) policy, which is in accordance with the JESD-46 standard. Please feel free to contact us if you have any questions. Inquiries may be submitted online, via the MyCases portal located on the Cypress web at URL www.cypress.com/myaccount. Ashwin Varma Quality Assurance Manager +1 (408) 943-2600 www.cypress.com/myaccount Test Report No.: GZ1101010694/CHEM Date: FEB 09, 2011 Page 1 of 10 QPL LIMITED NO.1, PIN ZHI ROAD, XIN AN INDUSTRIAL PARK, CHANG AN TOWN, DONGGUAN, GUANGDONG, CHINA The following sample(s) was/were submitted and identified on behalf of the applicant as C194 NiPdAu plating SGS Job No. : SZ12959189 SGS Internal Reference No. : 25.9 Client Reference Information : Sample may cover: QFN, DFN, SOP, HD-BU, SBP, SOIC, DUAL, QFP, PLCC, PDIP, TQFP Date of Sample Received : JAN 26, 2011 Testing Period : JAN 26, 2011 TO FEB 09, 2011 Test Requested : Selected test (s) as requested by client. Test Method : Please refer to next page(s). Test Result(s) : Please refer to next page(s). Signed for and on behalf of SGS-CSTC Ltd. ______________________ Manson Yang Approved Signatory Test Report No.: GZ1101010694/CHEM Date: FEB 09, 2011 Page 2 of 10 Test Results: Description for specimen 1 : Grey plating on metal Elementary Analysis Test Item(s) Cadmium (Cd) Unit mg/kg Lead (Pb) mg/kg Mercury (Hg) mg/kg Test Method (Reference) IEC 62321:2008 application of modified digestion by surface etching, ICP-OES IEC 62321:2008 application of modified digestion by surface etching, ICP-OES IEC 62321:2008 application of modified digestion by surface etching, ICP-OES Result MDL N.D. 2 N.D. 2 N.D. 2 Hexavalent Chromium (CrVI) by IEC 62321: 2008, UV-Vis Negative ◇ boiling water extraction Note: 1. mg/kg = ppm 2. N.D. = Not Detected (< MDL) 3. MDL = Method Detection Limit 4. ◇= Spot test: Negative = Absence of CrVI coating, Positive = Presence of CrVI coating; (The tested sample should be further verified by boiling water extraction method if the spot test result is negative or cannot be confirmed.) Boiling water extraction: Negative = Absence of CrVI coating Positive = Presence of CrVI coating; the detected concentration in boiling water extraction solution is equal or 2 greater than 0.02 mg/kg with 50cm sample surface area. Storage conditions and production date of the tested sample are unavailable and thus results of Cr(VI) represent status of the sample at the time of testing. 5. "-" = Not regulated Description for specimen 2 : Grey plated metal Flame Retardants Test Item(s) Sum of PBBs Monobromobiphenyl Dibromobiphenyl Tribromobiphenyl Tetrabromobiphenyl Pentabromobiphenyl Hexabromobiphenyl Heptabromobiphenyl Octabromobiphenyl Nonabromobiphenyl Decabromobiphenyl Sum of PBDEs Unit mg/kg mg/kg mg/kg mg/kg mg/kg mg/kg mg/kg mg/kg mg/kg mg/kg mg/kg mg/kg Test Method (Reference) IEC 62321: IEC 62321: IEC 62321: IEC 62321: IEC 62321: IEC 62321: IEC 62321: IEC 62321: IEC 62321: IEC 62321: 2008, 2008, 2008, 2008, 2008, 2008, 2008, 2008, 2008, 2008, - GC-MS GC-MS GC-MS GC-MS GC-MS GC-MS GC-MS GC-MS GC-MS GC-MS Result MDL N.D. N.D. N.D. N.D. N.D. N.D. N.D. N.D. N.D. N.D. N.D. N.D. 5 5 5 5 5 5 5 5 5 5 - Test Report Monobromodiphenyl ether Dibromodiphenyl ether Tribromodiphenyl ether Tetrabromodiphenyl ether Pentabromodiphenyl ether Hexabromodiphenyl ether Heptabromodiphenyl ether Octabromodiphenyl ether Nonabromodiphenyl ether Decabromodiphenyl ether No.: GZ1101010694/CHEM mg/kg mg/kg mg/kg mg/kg mg/kg mg/kg mg/kg mg/kg mg/kg mg/kg IEC 62321: IEC 62321: IEC 62321: IEC 62321: IEC 62321: IEC 62321: IEC 62321: IEC 62321: IEC 62321: IEC 62321: Date: FEB 09, 2011 2008, 2008, 2008, 2008, 2008, 2008, 2008, 2008, 2008, 2008, GC-MS GC-MS GC-MS GC-MS GC-MS GC-MS GC-MS GC-MS GC-MS GC-MS Page 3 of 10 N.D. N.D. N.D. N.D. N.D. N.D. N.D. N.D. N.D. N.D. 5 5 5 5 5 5 5 5 5 5 Note: 1. mg/kg = ppm 2. N.D. = Not Detected (< MDL) 3. MDL = Method Detection Limit 4. "-" = Not regulated PFOA & PFOS (Perfluorooctanoic acid & Perfluorooctane sulfonates) Test Item(s) Perfluorooctanoic acid (PFOA) Perfluorooctane sulfonates (PFOS) PFOS – Acid PFOS – Metal Salt PFOS – Amide Unit 2 µg/m Test Method (Reference) EPA 3550C: 2007, LC-MS Result N.D. MDL 1 2 EPA 3550C: 2007, LC-MS N.D. 1 µg/m Note: 1. mg/kg = ppm 2. N.D. = Not Detected (< MDL) 3. MDL = Method Detection Limit For reference: Entry 53 of Regulation (EC) No 552/2009 amending Annex XVII of REACH Regulation (EC) No 1907/2006 (previously restricted under Directive 2006/122/EC): (1) May not be placed on the market or used as a substance or constituent of preparations in a concentration equal to or higher than 0,005 % by mass. (2) May not be placed on the market in semi-finished products or articles, or parts thereof, if the concentration of PFOS is equal to or higher than 0,1% by mass calculated with reference to the mass of structurally or microstructurally distinct parts that contain PFOS or, for textiles or other coated materials, if the amount of PFOS is equal to or higher than 1µg 2 /m of the coated material. Test Report No.: GZ1101010694/CHEM Date: FEB 09, 2011 Page 4 of 10 Halogen Test Item(s) Fluorine (F) Chlorine (Cl) Bromine (Br) Iodine (l) Unit mg/kg mg/kg mg/kg mg/kg Test Method (Reference) BS EN 14582:2007, IC BS EN 14582:2007, IC BS EN 14582:2007, IC BS EN 14582:2007, IC Result N.D. N.D. N.D. N.D. MDL 50 50 50 50 Unit mg/kg Test Method (Reference) EPA 3050B: 1996, ICP-OES Result N.D. MDL 10 Note: 1. mg/kg = ppm 2. N.D. = Not Detected (< MDL) 3. MDL = Method Detection Limit Elementary Analysis Test Item(s) Antimony (Sb) Note: 1. mg/kg = ppm 2. N.D. = Not Detected (< MDL) 3. MDL = Method Detection Limit Test Report No.: GZ1101010694/CHEM Date: FEB 09, 2011 ATTACHMENTS Plating Pb/Cd/Hg Pb/Cd/Hg/Cr /Hg/Cr6+Testing Flow Chart 1) Name of the person who made testing: Bella Wang / Ross Zhan 2) Name of the person in charge of testing: Adams Yu 3) The plating which had been washed was dissolved totally by pre-conditioning method according to below flow chart. Sample Preparation Sample Measurement Cr6+ Pb/Cd/Hg Pb/Cd/Hg Metallic material Acid washing of plating layer Positive Precisely weighing sample after acid washing Filtration ICP-OES/AAS DATA Spot test Negative Boiling water extraction Adding 1,5diphenylcarbazide for color development A red color indicates the presence of Cr6+. If necessary, confirm with UV-Vis. DATA Page 5 of 10 Test Report No.: GZ1101010694/CHEM ATTACHMENTS PBBs / PBDEs Testing Flow Chart 1) Name of the person who made testing: Cutey Yu 2) Name of the person in charge of testing: Ryan Yang Sample cutting / preparation Sample Measurement Solvent extraction Concentration/Dilution Filtration GC-MS DATA Date: FEB 09, 2011 Page 6 of 10 Test Report No.: GZ1101010694/CHEM Date: FEB 09, 2011 ATTACHMENTS PFOA / PFOS Testing Flow Chart 1) Name of the person who made testing: Cindy Huang 2) Name of the person in charge of testing: Ryan Yang Sample cutting / preparation Sample Measurement Solvent extraction Concentration/Dilution Filtration LC-MS DATA Page 7 of 10 Test Report ATTACHMENTS No.: GZ1101010694/CHEM Date: FEB 09, 2011 Halogen Testing Flow Chart 1) Name of the person who made testing: Liang Wang 2) Name of the person in charge of testing: Michelle Song Sample cutting / preparation Sample Measurement Combustion in oxygen bomb Dissolved in an absorption solution Filtration Analyzed by ion chromatography. Double confirm by other instruments, if necessary DATA Page 8 of 10 Test Report ATTACHMENTS No.: GZ1101010694/CHEM Elementary Testing Testing Flow Chart 1) Name of the person who made testing: Bella Wang 2) Name of the person in charge of testing: Adams Yu Sample cutting / preparation Sample Measurement Acid digestion Filtration Solution ICP-OES/AAS DATA Date: FEB 09, 2011 Page 9 of 10 Test Report No.: GZ1101010694/CHEM Date: FEB 09, 2011 Sample photo : GZ1101010694/CHEM Specimen 1 GZ1101010694/CHEM Specimen 2 SGS authenticate the photo on original report only *** End of Report *** Page 10 of 10