BCM8228 Prodcut Brief

BCM8228
®
VARIRATE™ MULTIRATE TRANSCEIVER WITH SONET RATE ADAPTATION AND
PERFORMANCE MONITORING
SUMMARY OF BENEFITS
FEATURES
•
Highly integrated rate-adaptation device that maps a single STS-3/
STM-1 or a single STS-12/STM-4 stream into STS-48/STM-16 frames
•
Compliant with Optical Internetworking Forum (OIF), Telcordia®,
ITU-T, and IEEE 802.3 standards
•
Channel-add/channel-extract functionality for mapping and
extracting lower SONET rates
Reduces design cycle and time-to-market
•
Fully integrated serial clock and data recovery (CDR) 155-Mbps/
622-Mbps/2.488-Gbps SONET/SDH transceiver
•
•
•
Retiming functionality for GbE (SGMII)/FC, (CML)/2xFC, (CML)/
ESCON, (CML)/FICON (CML) rates; FE (125 Mbps), DVB
(270 Mbps)
•
Line-side serial interface, with flexible system-side interface supporting
SFI-4, TBI, and serial allowing connection to framers, MACs, switches,
etc.
•
Retiming functionality for STS-3/STM-1, STS-12/STM-4. and STS-48/
STM-16 rates (CML)
•
Enables new multirate and multiservice features while retaining
existing architectures
•
MUX/DEMUX functionality for STS-3/STM-1, STS-12/STM-4, and
STS-48/STM-16 rates (4-bit LVDS)
•
Integrated performance monitoring ensures higher reliability without
sacrificing cost or real estate
•
MUX/DEMUX functionality for GbE (TBI)/ESCON (10-bit)/FICON
(10-bit)
High level of integration allows for higher port density solutions
•
•
Pass-through functionality for other rates (DVB, HDTV etc.)
•
•
•
•
•
Redundant-receive inputs and transmit outputs to facilitate protection
switching designs
•
Two-wire/four-wire serial interface for register access and PM count
retrieval
•
•
Powers down unused blocks via register access
• Multiservice platforms
PRBS generators and detectors for inbound/outbound SONET and
inbound/outbound GbE
• Multiple-rate SONET/SDH transmission equipment
•
•
•
Polarity reversal for differential signals (low and high speed)
• SONET/SDH/GbE/FC multiservice boxes
Bit-order swapping for parallel bus (4-bit and 10-bit)
• ADD/DROP multiplexers
Exceeds SONET requirements for jitter generation, jitter transfer,
and jitter tolerance
• Optical and digital cross-connects
•
•
•
•
Core supply: 1.8V
Performance monitoring (PM) for SONET with optional sectionoverhead insertion
I/O power supplies: CML at 1.8V, CMOS at 1.8V or 3.3V
Single line-card design supporting rates from FE (125 Mbps) to
OC48+FEC (2.7 Gbps)
Bit-order swap allows for ease of PCB design
Uses the most effective silicon economy of scale for CMOS-based devices
Low-power consumption eliminates the need for external cooling
sources
APPLICATIONS
• SONET test equipment
• Terabit and edge routers
• Repeaters
Low-power consumption ~1.1W
Standard CMOS process available in standard 196-pin BGA and
Pb-free package
Application Diagram
BCM8228
Optical
Module
Optical
Module
BCM8228
Framer
or ASIC
Framer
or ASIC
BCM8228
Optical
Module
Optical
Module
BCM8228
OVERVIEW
RCK4O
Div4
1:4
DMUX
4
16
IB OC3/12
to STS48
Mapper
16 x 5
FIFO
16:4
MUX
High-Speed
Serial Input
LVDS 4-Bit
Output
Out
Reg
SONET/
GbE
CDR
lock_det
10:1
MUX
8b10
Error
Detect
1:10
DMUX
TBI
Reg
TCK4I
Wptr
4x9
FIFO
Reg
4:1
DMUX
4
OB STS48
to OC3/12
Mapper
16
4:16
DMUX
LOA
Det
Rptr
Div4
High-Speed
Serial Input
In
Reg
Par
to
Ser
LVDS 4-Bit
Input
Wptr
10 x 5
FIFO
Div10
Rptr
SONET/
GbE
CDR
Ser to
Par
1-Bit Input
Div 4
Ser to
Par
Div 10
8b10b
Error
Detect
In
Reg
TBI
BCM8228
BCM8228 Block Diagram
The BCM8228 VariRate™ device is a highly integrated variable-rate
transceiver/mapper operating at STS-48/12/3, GbE, FC/2xFC (Fibre
Channel), ESCON, FICON, FE, and DVB data rates. The device has an
integrated serial clock and data-recovery (CDR) circuit, loss-of-signal
(LOS) detection circuitry as well as an advanced feature set including
performance monitoring and a serial interface (2-wire or 4-wire) for
register access.
The BCM8228 reference clock input frequency is user-selectable to the
line rate divided by either 16 or 10. It can be powered with a single 1.8V
supply or dual 1.8V/3.3V supply without any special power-supply
sequencing requirements. Power consumption of the device is typically
1.1W. The Power-Down Control register turns off any unused blocks.
The BCM8228 is packaged in a 15-mm x 15-mm, 196-pin BGA.
The BCM8228 provides high jitter tolerance and low jitter generation to
comply with Optical Internetworking Forum (OIF), IEEE 802.3,
Telcordia, ANSI, and ITU-T standards.
Broadcom®, the pulse logo, Connecting everything®, the Connecting everything logo, and VariRate™
are among the trademarks of Broadcom Corporation and/or its affiliates in the United States, certain
other countries and/or the EU. Any other trademarks or trade names mentioned are the property of their
respective owners.
®
BROADCOM CORPORATION
16215 Alton Parkway, P.O. Box 57013
Irvine, California 92619-7013
© 2006 by BROADCOM CORPORATION. All rights reserved.
8228-PB06-R
04/17/06
Phone: 949-450-8700
Fax: 949-450-8710
E-mail: [email protected]
Web: www.broadcom.com