VEAM CIR Connectors
Introducing the most versatile
multipin connector in the world...
is the most versatile electrical, optical and pneumatic multipin connector available today.
The
Designed originally for the hostile environment of Transit applications, CIR has earned acceptance in Military,
Commercial, Medical, Geophysical, Entertainment, Nuclear, Aerospace. Ground support and comparable areas
requiring nearly non-destructible cable or wire terminations.
The electrical design parameters of CIR were based on MIL-DTL-5015. However, its unique positive lock, quick
disconnect coupling surpasses the environmental requirements of this military specification. To enhance service
life, CIR connectors feature stainless steel anti-wear rings at the critical point of the receptacle coupling ramps.
The CIR design has been adopted by NATO as the “standard connector for Ground Fighting Vehicles” and is
used extensively in U.S. and European military programs: Based on standard VG 95234.
CIR
K
*Trademark-DuPont
Dimensions shown in inches (mm)
Specifications and dimensions subject to change
K-4
www.ittcannon.com
ca_K1-K15.qxd:Layout 1
2/10/11
1:21 PM
Page 5
VEAM CIR Connectors
1. Quick coupling and uncoupling 120º
coupling nut rotation.
2. High shock 50 g’s and vibration
resistance 20 g’s - Lockwires not
required.
3. No coupling threads to gall or bind due
to wear or contamination
4. Audible, Visual, and Tactile indication
of full coupling.
5. Waterproof to 10 meters (33 ft.)
12 Hours (14.7 PSI)
6. 2,000 couplings max.
7. Elastomer temperature ranges:
- 55º C. to + 125º C. Neoprene
- 55º C. to + 200º C. Silicone
- 25º C. to + 200º C. Viton*
- 40º C. to + 125º C. FR (flame retardant)
General Specifications
Aluminum alloy. Options include stainless steel, bronze and plastic
composite.
materials and finishes, consult our Customer Service Department.
Polychloroprene (Neoprene). Options include silicone, fluorocarbon
(Viton*) and FR (Flame Retardant) rubber.
Copper alloy or thermocouple alloys.
Silver (T9), gold (standard - T12, heavy -T112) and Rhodium plating.
are produced in accordance with NATO Standard VG95234, which
is based on MIL-DTL-5015 for physical size, layout and environmental requirements.
* Trademark-Dupont
Note: CIR connectors are available with cadmium free and lead free materials.
Dimensions shown in inches (mm)
Specifications and dimensions subject to change
www.ittcannon.com
K-5
CIR
Hard Black Anodize (T89), Non-cadmium (Green-T100), (Black-T108)
Electroless Nickel (T29), Cadmium-olive drab (T3).
K
ca_K1-K15.qxd:Layout 1
2/10/11
1:21 PM
Page 6
VEAM CIR Connectors
Part Number Generation
RECEPTACLES
PLUGS
Standard
backshell
A/R
00/020
AL/RL
RL/LR
PG/M
02
Same accessories as plug connectors
CF/CFZ
Standard C/N
01/010
LCF/LCFZ
06
F/AF
030
LF/LAF
Rubber Covered C/N
03
Mates
90º backshell - Plug style 08
06xxGG
with
K
RV/ARV
Single Wire
(No Clamp)
CIR
05
Heavy duty C/N
065
G/AG
G2/AG2
07
Swivel Backshell
heat shrink tube
SB
Panel mounting plug
MGS
Gland Seal
Cable Clamp
070
26/064
WCML (special shielding system)
Consult factory
WN
TB
Dimensions shown in inches (mm)
Specifications and dimensions subject to change
K-6
www.ittcannon.com
ca_K1-K15.qxd:Layout 1
2/10/11
1:21 PM
Page 7
VEAM CIR Connectors
Part Number Generation
BACKSHELL AND ACCESSORIES
ADAPTERS AND CABLE CLAMPS
Long
backshell
Internal/external
PG or metric thread
Cable clamp and
seal (jacketed cable)
Long style
08A/R
Standard
elbow
Cable clamp and
seal (jacketed cable)
FSxxxx
Adapter for UNI 4883
rubber tube
Cable Clamp
(single wire)
08CF
08CFZ
08SB
RFI Shielded cable
Swivel Backshell
heat shrink tube
PG
Internal/external
PG or metric thread adapter
Non-metallic fitting
Strain relief
and Seal
Dimensions shown in inches (mm)
Specifications and dimensions subject to change
www.ittcannon.com
SL
K
CIR
Heat shrink
tube
Cable clamp and
Cable clamp elbow
seal elbow (jacketed cable)
(single wire)
08F
08AF
Non-metallic
spiral fitting
RFI Shielded cable
elbow heat shrink tube
Cable clamp
(single wire)
long style
SLX
K-7
ca_K1-K15.qxd:Layout 1
2/10/11
1:21 PM
Page 8
VEAM CIR Connectors
Standard Part Number Generation - Line Configurator
FR
CIR
G
030
RV
18
19
P
W
F80
TXXX YYY
Prefix
Connector series
Alternate material
Shell Style
Environmental Class
Shell Size
Insert Arrangement
Contact Gender
Alternate Insert Rotations
Contact Type
Plating Code
Modifications
PREFIX
FR.....Flame retardant materials
INSERT ARRANGEMENT
Defined by the quantity and size of the contacts.
Refer to VEAM CIR Series catalog for available options.
CONNECTOR SERIES
CIR....Bayonet coupling
CIR
K
CONTACT GENDER
P............. Male contacts
S... ......... Female contacts
PS...........Thru-bulkhead contacts (female-male)
PP - Thru-bulkhead contacts (male-male)
ALTERNATE MATERIAL
G......Plug with RFI grounding
V.......Fluoroelastomers
P....... Plastic connector shells
SP..... Plastic receptacle shell without ramp rings
SHELL STYLE
01/010..............In-line receptacle-Round flange with flats
020/00.......Front panel mount receptacle, rear thread
02..............Front panel mount receptacle, no rear thread
03..............Rear panel mount receptacle, no rear thread
030............Rear panel mount receptacle, rear thread
038............Rear/Front mount receptacle with 90º backshells
05..............Dummy receptacle
07..............Single hole mount jamnut receptacle, no read thread
070............Single hole mount jamnut receptacle, read thread
078............Single hole mount jamnut receptacle with 90º backshells
TB..............Thru-bulkhead receptacle
06..............Straight plug connector
065............Straight plug connector with heavy duty coupling nut
26/064PP....Panel plug
08..............90 degree plug connector
ENVIRONMENTAL CLASS
Different classes are based on the type of backshell, sealing
capability and accessories. Refer to pages 49 to 57.
ALTERNATE INSERT POSITION
W, X, Y, Z, Q - Refer to VEAM CIR Series catalog
for available options.
CONTACT TYPE
F80.........Crimp for AWG wire (used in F80 insert)
CR...........Crimp for metric wire (used in metric insert)
CR1.........Crimp for AWG wire (used in metric insert)
PC...........Pneumatic contacts
VO...........Contacts not supplied
NO SUFFIX........Solder (standard class)
PLATING CODE OF SHELLS
T29.........Electroless Nickel
T39.........Black epoxyurhetanic varnish
T89.........Black hard anodize
T100.......Zinc/cobalt Ecogreen
T108.......Zinc/cobalt Ecoblack
Other plating available. Please consult the factory.
MODIFICATIONS
VO.........Supplied less contacts
Consult factory
SHELL SIZE
10SL, 14S, 16S, 16, 18, 20, 22, 24, 28, 32, 36, 40
Dimensions shown in inches (mm)
Specifications and dimensions subject to change
K-8
www.ittcannon.com
ca_K1-K15.qxd:Layout 1
2/10/11
1:21 PM
Page 9
VEAM CIR Connectors
Contact Disengaging Force Meets or Exceeds MIL-C-3909
18-20
16-16S
12
8
4
0
4/0*
.7
2.0
3.0
5.0
10.0
15.0
15.0
CIR Coupling - Uncoupling Torque Values per VG95234
.19
.56
.83
1.39
2.78
4.17
4.17
10SL
14S
16S
16
18
20
22
24
28
32
36
40
*Not included in MIL-Spec
Backshell / Clamp Torque Forces
10SL
14S
16
16S
18
20
26/31
44/49
57/66
57/66
61/69
69/87
22
24
28
32
36
40
87/104
96/130
121/165
130/182
165/235
182/347
7.5 A
10 A
22 A
41 A
73 A
135 A
245 A
350 A
I
A
D
E
B
C
I
A
D
E
B
C
attenuation
0
10
MHz 100
frequency
Dimensions shown in inches (mm)
Specifications and dimensions subject to change
www.ittcannon.com
1000 V
2000 V
2800 V
3500 V
4500 V
7000 V
10
20
0,3
15-15S
16-16S
1
25
12
1,5
60-100
8
3
160
4
4
500
0
8,5
Separating force per contact
The corresponding separating force has to be
measured according to VG95319, part 2, test no.
5.7.using the required test gage.
20
1
1400 V
2800 V
3600 V
4500 V
5700 V
8500 V
The connectors do not show any signs of breakdown
when the test voltage indicated in the
table is applied
Min.disengaging
for one minute
between
Contact
Size the two closest contacts
force and
between
and the
contact closest
to the shell.
CR the shell CR1e
F80
N (Newton)
40
0.1
200 V
500 V
900 V
1250 V
1750 V
3000 V
Dielectric Strength (Standard at Sea Level Conditions)
80
70
60
0.01
250 V
700 V
1250 V
1750 V
2450 V
4200 V
K
83 mV
83 mV
74 mV
63 mV
65 mV
58 mV
53 mV
53 mV
Shielding Characteristics
dB
1.0
3.0
4.0
4.0
4.9
5.9
6.9
6.9
8.0
8.9
8.9
13.0
Insert Arrangement Service Rating
*
7.5 A
7.5 A
13 A
23 A
46 A
80 A
150 A
225 A
1.15
3.5
4.6
4.6
5.75
6.9
8.0
8.0
9.2
10.3
10.3
15.0
CIR
20
18
16-16S
12
8
4
0
4/0
12.0
20.0
23.9
23.9
27.9
31.9
35.9
43.9
52.0
65.0
73.7
73.7
Connector and Contact Ratings
Contact Rating
*
13.8
23.0
27.6
27.6
32.2
36.8
41.4
50.6
60.0
75.0
85.0
85.0
K-9
ca_K1-K15.qxd:Layout 1
2/10/11
1:21 PM
Page 10
VEAM CIR Connectors
Inserts by Contact Quantity
Contact
Quantity
Insert
Arrangement
Standard Contact / Current Rating / Wire Size / MM
20
7.5 A
20
AWG
0.52
CIR
K
1
1
1
1
1
1
1
1
1
1
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
16-2
16-12
18-6
18-16 *
18-61 *
20-2
22-7
24A-1
32A-1
36A-1 *
10SL-4
14S-9
16S-4
16-11
16-13 (TC)
18-3
18-14
20-23
22-1
22-8
22-11
24A-2 *
24-9
32A-2 *
32-5
32D-2 *
36A-2
40A-2 *
10SL-3
10SL-55 (TC)
14S-1
14S-7
14S-12 (14S-1x100°)
16S-5
16-7
16-10
18-5
18-22
20-3
20-19
22-2
22-6
22-9
22-21
28-3
28-6
28P-3 *
32A-3
18
7.5 A
18
AWG
0.82
16
13 A
16
AWG
1.3
12
23 A
12-14
AWG
3.3-2.1
8
46 A
8
AWG
8.6
4
80 A
4
AWG
21
0
150 A
0
AWG
56
2
Service Rating
4/0
225 A
4/0
AWG
107
1
1
1
1
1 coax
1
1
1
1
1
2
2
2
2
2
2
1
1
2
2
2
2
2
2
1
1
2
1
1
2
1
3
3
3
3
3
3
2
1
3
1
1
3
2
3
3
3
2
1
3
2
1
3
3
3
3
E
A
D
C
D
D
E
B
B
C
A
A
D
A
A
D
A
A
D
E
B
HV (4200 VDC)
A
D
D
A
A
D
A
I
A
A
A
A
A
A
D
D
D
A
D
D
E
A
E
D
C
B
* Note: For insert arrangements in blue, consult our Customer Service Department.
Dimensions shown in inches (mm)
Specifications and dimensions subject to change
K-10
www.ittcannon.com
ca_K1-K15.qxd:Layout 1
2/10/11
1:21 PM
Page 11
VEAM CIR Connectors
Inserts by Contact Quantity
Contact
Quantity
Insert Arrangement
Standard Contact / Current Ratings / Wire Size
20
7.5 A
20
AWG
14S-2
14S-10
16-9
18-4
18-10
18-13
20-4
20-24
22-4
22-22
24-22
32-17
36-5
40D-4
14S-5
16S-8
18-11
18-20
18-30 (18-20x110º)
18-31 (18-20x260º)
22-12
22-34
24-12
28-5
28A-5GM
32-1
32-2
32A-5GM
32B-5(GM)
40A-3 *
40A-5GM
40B-5 *
14S-6
18-06 *
18-12
20-8
20-17
20-22
22-5
22-15
24-06
24A-6
28-22
28A-6
36-3
36-6
32A-6
36A-51
6
36A-61*
16
13 A
16
AWG
4
4
2
4
12
23 A
12
AWG
8
46 A
8
AWG
0
150 A
0
AWG
2
4
3
4
2
2
1
2
2
4
4
4
4
4
5
5
5
5
5
5
3
2
2
2
3
3
1
2
2
5
3
2
2
3
5
5
2
1
6
2
6
4
1
3
4
1
2
1
2
5
3
2
5
4
3
1
4
2
4
3
1
3
4
1
4
Dimensions shown in inches (mm)
Specifications and dimensions subject to change
K-11
3
5
3
4
* Note: For insert arrangements in blue, consult our Customer Service Department.
www.ittcannon.com
4
80 A
4
AWG
4
2
2
2
3
2
3
4/0
225 A
4/0
AWG
I
I
A
D
A
A
D
A
A
A
D
D
A
C
I
A
A
A
A
A
D
D
A
D
A
A=E; B,C,D,E=D
E
A
A
E
A
A
I
A
A
I
A
A
D
D=E; A,B,C,E,F=A
D
D
D
A
D
A
E
D
E
K
CIR
4
4
4
4
4
4
4
4
4
4
4
4
4
4
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
18
7.5 A
18
AWG
Service Rating
ca_K1-K15.qxd:Layout 1
2/10/11
1:21 PM
Page 12
VEAM CIR Connectors
Inserts by Contact Quantity
Contact
Quantity
Insert Arrangement
Standard Contact / Current Rating / Wire Size
20
7.5 A
20-22
AWG
6
6
6
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
8
8
8
8
CIR
K
36B-6
36B-61
40A-4
14SA-7 *
16S-1
18-9
18-17 (18-9x100º)
20-15
20A-7
22-28
24-2(GM)
24-10
24-27
24A-7
28-10
28A-7
28B-7*
32A-7
36-77
40A-7 *
18-8
20-7
18
7.5 A
18-20
AWG
22-23
8
24-6 (HM)
8
8
8
8
8
9
9
9
9
9
9
9
9
9
9
10
10
10
10
10
10
24A-8 *
32-15
32A-8
40A-8
40A-10
20-16
20-18
20-21
20A-9
22-17
22-27 (CR)
22A-9
24-11(EM)
28-1
28A-9
16A-10
18-1
18-19
18-24 (18-1x250º)
22A-10
22B-10*
12
23 A
12-14
AWG
8
46 A
8
AWG
2
1
4
2
3
7
7
5
5
4
80 A
4-6
AWG
0
150 A
0
AWG
8
8
A,G,H=D; BAL.=A
4
2
2
7
7
7
7
7
7
3
2
4
2
3
7
4
7
8
3
7
2
1
6
8
5
2
8
6
2
8
4
4
7
6
8
8
8
9
4/0
225 A
4/0
AWG
B
E
A
I
A
I
I
A
D
A
D
A
E
D
G=D; BAL.=A
A
A
D
D
A
A
A,B,H,G=D
C,D,E,F=A
I
A,B,F,G,H=D
C,D,E=A
H=D; BAL.=A
2
7
20A-8
22-18
8
16
13 A
16-18
AWG
Service Rating
4
4
2
3
1
9
1
1
6
6
3
3
5
4
10
10
10
10
10
8
2
HV (15KV)
D
A
E
D
A
A
A
J=D; BAL.=A
A=D; BAL.=A
J=D; BAL.=A
1,2,3=D; BAL=A
A
A,J,E=D;BAL.=A
A
A
B,C,F,G=A; BAL.=I
A
B,C,F,G=A; BAL.=I
A
A
* Note: For insert arrangements in blue, consult our Customer Service Department.
Dimensions shown in inches (mm)
Specifications and dimensions subject to change
K-12
www.ittcannon.com
ca_K1-K15.qxd:Layout 1
2/10/11
1:22 PM
Page 13
VEAM CIR Connectors
Inserts by Contact Quantity
Contact
Quantity
Insert Arrangement
Standard Contact / Current Rating / Wire Size / MM 2
20
18
16
12
8
7.5 A 7.5 A 13 A 23 A 46 A
20
18
16
12
8
AWG AWG AWG AWG AWG
0.52 0.82
1.3 3.3-2.1 8.6
24-21
28-19
28A-10 *
32A-10 *
36A-10 *
36B-10 *
20-33
20A-11 *
24-20
24A-11
24-19
28-9
12
28-18
12
12
12
13
13
13
13
13
14
14
14
14
14
14
14
14
14
14
14
15
16
16
16
16
16
16
17
17
19
19
19
19
19
19
19
20
20
21
22
28-51
36A-12
36B-12
20-11
20-25 (20-11x100°)
20-30 (20-11x250°)
24-013 *
32A-13
20-27
22-19
28-2
28-20
28A-14
32-9
32A-14 *
36-78
36B-78
36D-78
40A-14 *
28-17
22A-16 *
24-5
24-7
24A-16 *
28A-16 *
32-68
20-29
28-59
20A-48
22-14
24-67
32-76
40-19
40A-19
40B-19
28-16
40A-20
40A-21
28-11
9
6
1
4
10
8
8
8
5
11
5
9
9
12
6
2
2
2
1
2
2
6
12
12
3
13
13
13
7
14
14
12
4
3
10
3
2
3
6
13
2
10
14
12
14
2
2
4
2
12
12
10
6
15
16
16
14
15
12
12
17
10
19
19
8
2
1
4
4
7
19
19
17
17
19
2
2
20
18
18
20
4
2
1
* Note: For insert arrangements in blue, consult our Customer Service Department.
Dimensions shown in inches (mm)
Specifications and dimensions subject to change
www.ittcannon.com
K-13
0
150 A
0
AWG
56
4/0
225 A
4/0
AWG
107
D
H,M=B; A,B=D; BAL.=A
D
A
A
A
A
A
D
A
A
D
M=C; G,H,J,K,L=D
A,B=A; BAL.=I
D
A
D
I
I
I
A
D
A
A
D
A
D
D
HV (6000 VAC)
D
D
D
A
R=B; M,N,P=D; BAL.=A
I
A
A
E
A
A
A
A
I
A
A
A
A
A
A
A
D
21=D; BAL.=A
A
K
CIR
10
10
10
10
10
10
11
11
11
11
12
12
4
80 A
4
AWG
21
Service Rating
ca_K1-K15.qxd:Layout 1
2/10/11
1:22 PM
Page 14
VEAM CIR Connectors
Inserts by Contact Quantity
Contact
Quantity
Insert Arrangement
Standard Contact / Current Rating / Wire Size
20
7.5 A
20
AWG
CIR
K
22
22
22
23
23
23
24
24
25
25
25
26
26
27
27
28
28
28
29
29
29
29
30
30
30
31
31
31
31
31
31
32A-22
32B-22 *
36A-22
32-6
32-13
32-16
24-28
40A-24
24A-25
32A-25
40A-25
28-12
28-13
32A-27
40A-27
24A-28
28A-63(CR)
32A-28
20A-29 *
28A-29 *
40-10
40A-29 *
32-8
32A-30
40A-30
28A-31 *
32-31
32A-31 *
36-9
36-18 (36-9x100º)
40A-31
34
35
35
35
35
35
35
37
37
37
37
38
39
40
42
44
47
40A-34 *
28-15
28A-35
28B-35
32-7
36-15
40A-35
22A-37
28-21
40B-37
40D-37 *
40A-38
36-54
32A-40
32-59
36-74 *
36-7
18
7.5 A
18
AWG
16
13 A
16
AWG
12
23 A
12
AWG
8
46 A
8
AWG
20
20
16
18
16
24
4
80 A
4
AWG
22
2
5
2
16
3
2
3
2
8
25
26
26
17
28
19
25
27
16
5
24
20
25
24
1
10
25
2
9
28
4
18
6
10
29
25
2
9
6
4
1
6
31
13
14
14
35
35
35
28
35
18
14
14
31
2
2
33
1
7
35
37
37
37
37
38
31
40
40
43
40
4/0
0
150 A 225 A
4/0
0
AWG AWG
2
2
8
2
1
7
1
1
Service Rating
A
A
D
A
D
A
I
D
I
A
A
A
A
A
A
I
e=A; BAL.= l
A
I
A
A
A
A
A
A
I
A
A
A
A
D
I
A
A
A
A,B,h,j=I; BAL.=A
M=D; BAL.=A
D
A
A
A
A
A
A
A
A
A
A
* Note: For insert arrangements in blue, consult our Customer Service Department.
Dimensions shown in inches (mm)
Specifications and dimensions subject to change
K-14
www.ittcannon.com
ca_K1-K15.qxd:Layout 1
2/10/11
1:22 PM
Page 15
VEAM CIR Connectors
Inserts by Contact Quantity
Contact
Quantity
Insert Arrangement
Standard Contact / Current Rating / Wire Size
20
7.5 A
20
AWG
36-8
36-16 (36-7x100º)
36-17 (36-7x110º)
40-9
40A-47
32A-48
36-10
36-11 (36-10x100º)
36-12 (36-10x110º)
36A-48
32-22
24A-55
32A-55
40-55 *
36-66
40-58 *
40A-60
32A-69 (CR)
40-63 *
40A-62
28-72
36A-72
40-56
40A-56
40A-100
32-101
40A-130
40A-150 *
40T-159 *
16
13 A
16
AWG
12
23 A
12
AWG
46
40
40
24
24
48
48
48
48
48
54
1
7
7
22
22
8
46 A
8
AWG
1
1
55
55
35
52
38
60
20
61
60
41
19
4
19
1
1
2
72
52
16
85
85
4
12
4
100
101
114
150
159
* Note: For insert arrangements in blue, consult our Customer Service Department.
For product details please see the VEAM CIR Series full line catalog.
Dimensions shown in inches (mm)
Specifications and dimensions subject to change
www.ittcannon.com
K-15
4
80 A
4
AWG
0
4/0
150 A 225 A
0
4/0
AWG AWG
A
A
A
A
A
I
A
A
A
I
A
I
A
I
A
I
A
A
A
A
I
I
A
A
A
I
I
I
I
K
CIR
47
47
47
47
47
48
48
48
48
48
54
55
55
55
56
58
60
61
61
62
72
72
85
85
100
101
130
150
159
18
7.5 A
18
AWG
Service Rating