Catalog pages - Hammond Manufacturing

www.hammondmfg.com
1414 PH Series Enclosures - NEMA 12, 13
Continuous Hinge, Clamped Cover
Industrial Enclosures
Junction Boxes
Application
Construction
Finish
• Designed for use as instrument
enclosures, electric, hydraulic
or pneumatic control housings,
electrical junction boxes or terminal
wiring enclosures.
• Provides a degree of protection
from falling dirt, dust, oil and water.
• Body formed from 16 gauge or 14
gauge steel. Covers are formed
from 14 gauge steel.
• Smooth, continuously welded
seams without knockouts, cutouts
or holes.
• Welded brackets provide for
enclosure mounting.
• Continuously hinged cover is
secured with stainless steel clamps
and plated steel screws.
• Seamless poured-in place gasket.
• Models larger than 4" x 4" include a
removable 14 gauge inner panel.
• Internal threaded weld studs are
provided for mounting inner panels.
• A bonding stud is provided on
the door and a grounding stud is
provided in the enclosure.
• Cover and enclosure are
phosphatized and finished in ANSI
61 gray recoatable powder coating.
• Removable inner panel is finished in
white powder coating.
Standards
• UL 508 Type 12, 13
• CSA Type 12, 13
• Complies with
• NEMA Type 12 and 13
• JIC EGP-1-1967 unless marked1
• IEC 60529, IP54
Technical references and CAD downloads available at www.hammondmfg.com
9
Accessories
• Additional inner panels...see page 436
• Breather kits...see page 400-401
• Door clamping hardware
...see page 429
• Filter fans...see page 371-384
• Heaters...see page 393-396
• Louvered ventilating plates
...see page 402
• Terminal kit assemblies
...see page 441
• Thermostats...see page 397
• Swing panel...see page 440
All dimensions in inches unless specified otherwise
Quality Products. Service Excellence.
© Hammond Manufacturing
Canada: 519.822.2960 or 905.456.3770
USA: 716.630.7030
Data Subject to change without notice
www.hammondmfg.com
1414 PH Series Enclosures - NEMA 12, 13
Continuous Hinge, Clamped Cover
Industrial Enclosures
Part No.
Part No.
Without
Inner Panel
Panel Size
B
C
D
E
F
G
H
J
L
4
—
1414PHA1
6
1414PHC1
1414PHCLP1
8
1414PHG
1414PHGLP
1414PHRG 1414PHRGLP 6
4
—
1414PHA41
1414PHC41 1414PHC4LP1 6
6
1414PHE
1414PHELP
8
1414PHH4 1414PHH4LP
10
1414PHI
1414PHILP
8
1414PHRI
1414PHRILP
1414PHKC4 1414PHKC4LP 12
12
1414PHK
1414PHKLP
1414PHRK 1414PHRKLP 10
8
1414PHG6 1414PHG6LP
10
1414PHI6
1414PHI6LP
10
1414PHJ6
1414PHJ6LP
1414PHL6 1414PHL6LP 12
1414PHMH6 1414PHMH6LP 14
1414PHM6 1414PHM6LP 14
1414PHRM6 1414PHRM6LP 12
1414PHN6 1414PHN6LP 16
1414PHO6 1414PHO6LP 16
1414PHRO6 1414PHRO6LP 14
1414PHK8 1414PHK8LP 12
1414PHM8 1414PHM8LP 14
1414PHO8 1414PHO8LP 16
1414PHO10 1414PHO10LP 16
1
Does not meet JIC requirements
4
4
6
8
4
4
6
8
8
10
6
10
12
6
8
10
12
8
12
14
10
14
16
10
12
14
14
3.0
3.0
3.5
3.5
4.0
4.0
4.0
4.0
4.0
4.0
4.0
5.0
5.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
8.0
8.0
8.0
10.0
—
4.88
6.75
4.88
—
4.88
4.88
6.75
8.75
6.88
10.75
10.75
8.88
6.75
8.75
8.75
10.75
12.75
12.75
10.88
14.75
14.75
12.88
10.75
12.75
14.75
14.75
—
2.88
4.88
6.75
—
2.88
4.88
6.88
6.88
8.75
4.88
8.88
10.75
4.88
6.88
8.88
10.88
6.88
10.88
12.75
8.88
12.88
14.75
8.88
10.88
12.88
12.88
—
2.51
3.01
3.01
—
3.51
3.51
3.51
3.51
3.51
3.51
4.51
4.51
5.51
5.51
5.51
5.51
5.51
5.51
5.51
5.51
5.51
5.51
7.51
7.51
7.51
9.51
4.75
6.75
8.75
6.75
4.75
6.75
6.75
8.75
10.75
8.75
12.75
12.75
10.75
8.75
10.75
10.75
12.75
14.75
14.75
12.75
16.75
16.75
14.75
12.75
14.75
16.75
16.75
2
2
4
6
2
2
4
6
6
8
4
8
10
4
6
8
10
6
10
12
8
12
14
8
10
12
12
2.64
2.64
3.14
3.14
3.64
3.64
3.64
3.64
3.64
3.64
3.64
4.64
4.64
5.64
5.64
5.64
5.64
5.64
5.64
5.64
5.64
5.64
5.64
7.64
7.64
7.64
9.64
5.5
7.5
9.5
7.5
5.5
7.5
7.5
9.5
11.5
9.5
13.5
13.5
11.5
9.5
11.5
11.5
13.5
15.5
15.5
13.5
17.5
17.5
15.5
13.5
15.5
17.5
17.5
Technical references and CAD downloads available at www.hammondmfg.com
4.31
6.31
8.31
6.31
4.31
6.31
6.31
8.31
10.31
8.31
12.31
12.31
10.31
8.31
10.31
10.31
12.31
14.31
14.31
12.31
16.31
16.31
14.31
12.31
14.31
16.31
16.31
4.31
4.31
6.31
8.31
4.31
4.31
6.31
8.31
8.31
10.31
6.31
10.31
12.31
6.31
8.31
10.31
12.31
8.31
12.31
14.31
10.31
14.31
16.31
10.31
12.31
14.31
14.31
P
T
U
V
Y
Z
1.5
2.5
1.0
2.5
1.5
2.5
2.5
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
3
3
5
7
3
3
5
7
7
9
5
9
11
5
7
9
11
7
11
13
9
13
15
9
11
13
13
—
.31
.31
.25
—
.31
.31
.31
.31
.25
.31
.31
.25
.31
.31
.31
.31
.31
.31
.25
.31
.31
.25
.31
.31
.31
.31
—
.31
.25
.31
—
.31
.31
.25
.25
.31
.25
.25
.31
.25
.25
.25
.25
.25
.25
.31
.25
.25
.31
.25
.25
.25
.25
—
.56
.63
.56
—
.56
.56
.63
.63
.56
.63
.63
.56
.63
.63
.63
.63
.63
.63
.56
.63
.63
.56
.63
.63
.63
.63
—
.56
.56
.63
—
.56
.56
.56
.56
.63
.56
.56
.63
.56
.56
.56
.56
.56
.56
.63
.56
.56
.63
.56
.56
.56
.56
Ship
wt.
w/Pnl
—
3
6
6
—
4
5
8
10
10
10
13
13
8
12
14
17
12
19
19
18
23
23
18
20
25
26
Ship
wt.
n/
Pnl
2
2
5
5
3
3
4
7
8
8
8
10
12
7
10
12
15
10
17
17
15
21
21
15
18
22
23
All dimensions in inches unless specified otherwise
Quality Products. Service Excellence.
© Hammond Manufacturing
Canada: 519.822.2960 or 905.456.3770
Junction Boxes
A
Cover
Dimensions
USA: 716.630.7030
Data Subject to change without notice
10