AN143 : X3100 Voltage Measurement Accuracy

X3100 Voltage Measurement Accuracy
®
Application Note
Description
This test measures the accuracy of the celll voltage
measurement circuits of the X3100. In the test, a known
voltage is applied across each cell input of the X3100. The
analog output voltage of the X3100 is measured for each
cell. This value is compared to the input voltage. The
collected data includes the values from three devices from
three different lots. The data also includes tests at 0°C, 25°C
and 50°C.
Test Setup
For this test, Vcc was held at 16V to prevent the device
entering the sleep mode when testing cell voltages below
2V. In the test 4V was applied to all cells, except the cell
being measured. The voltage was applied at 10mV intervals
over four ranges. These input ranges were 1.5 to 1.7V, 2.5 to
2.7V, 3.5 to 3.7V and 4.0 to 4.2V.
16V
For each cell and each applied voltage the output was
recorded. This involves the changing of the analog
multiplexer setting in the X3100. In gathering the data with
this test, the output was sample. This procedure was used to
reduce the effect of external noise on the test environment.
Results
The data for this test is available in raw form in an Excel
spreadsheet. This spreadsheet includes data for each
device, data for each lot, and data for all devices. Each set of
data includes results for the three temperature settings and
the four gain settings. The data was copied to other files for
the purposes of generating graphs.
The result summaries show the output error as a
percentage. This error is provided for each of 3 lots as well
as the combined data. Data is averaged, and standard
deviation computed, from samples taken at three
temperatures 0°C, 25°C and 50°C.
VCELL1
AO
+
AN143.0
On the following charts, absolute error is the Output minus
the Input, while the percent error is calculated as follows:
X3100
+
May 9, 2005
VCELL2
Output – Input
Error = ----------------------------------------Input
Overall Performance
+
+
VCELL3
VCELL4
VSS
The following set of graphs shows the performance of the
X3100 over temperature and across three lots of three
devices. The graphs will show the basic input/output curve,
raw error, and error after correction for offset and gain.
The below data shows that the X3100 output is accurate,
with 3 standard deviations, to better than 2.5% error across
all measured voltages. It also shows that over the key range
of 2.5 to 4.2V, accuracies of better than 1% can be expected.
These accuracies are not dependent on any calibration
factors.
FIGURE 1. CELL VOLTAGE MEASUREMENT
1
CAUTION: These devices are sensitive to electrostatic discharge; follow proper IC Handling Procedures.
1-888-INTERSIL or 1-888-468-3774 | Intersil (and design) is a registered trademark of Intersil Americas Inc.
Copyright Intersil Americas Inc. 2005. All Rights Reserved
All other trademarks mentioned are the property of their respective owners.
Application Note 143
HP6626
Power Supply
X3100
+
HP6626
Power Supply
VCC
VCELL1
+
VRGP
VCELL2
VRGC
+
VCELL3
VRGO
+
Keithley 2002
VCELL4
DMM
VSS
AO
Keithley 2000
DMM
SPI Serial
Analog Select
VCS1
VCS2
20.37
Ohm
Keithley 236
Source Measurement Unit
PC
FIGURE 1. CHARACTERIZATION TEST SETUP
2
AN143.0
May 9, 2005
Application Note 143
Lot 1
Voltage Measurement Output Error - Cell 1
Lot 1
Voltage Output Error - Cell 1 (Lot 1)
3.0%
2.0%
Output Error (V)
000.0E+0
-2.0E-3 1
1.5
2
2.5
3
3.5
4
4.5
1.0%
-6.0E-3
0.0%
-1.0% 1
-8.0E-3
-2.0%
-10.0E-3
-3.0%
-4.0E-3
1.5
2
2.5
3
3.5
4
4.5
Input Voltage
-12.0E-3
Input Voltage
0degC
25degC
0degC Average
0degC +3 STD
0degC -3 STD
50degC
FIGURE 2A.
25degC Average
25degC + 3STD
25degC -3 STD
50degC Average
50degC +3 STD
50degC -3 STD
FIGURE 2B.
FIGURE 2. INPUT TO OUTPUT VOLTAGE ERROR - CELL 1
Voltage Output Error - Cell 2 (Lot 1)
Voltage Measurement Output Error - Cell 2
Lot 1
4.0%
Output Error (V)
3.0%
15.0E-3
2.0%
10.0E-3
1.0%
5.0E-3
0.0%
000.0E+0
-1.0%
1
1.5
2
2.5
3
3.5
4
4.5
1.0
1.5
2.0
25degC
3.0
3.5
4.0
4.5
-2.0%
Input Voltage (V)
0degC
2.5
Input Voltage
50degC
0degC Average
0degC +3STD
0degC -3STD
25degC Average
25degC +3STD
25degC -3STD
50degC Average
50degC +3STD
50degC -3STD
FIGURE 3B.
FIGURE 3A.
FIGURE 3. INPUT TO OUTPUT VOLTAGE ERROR - CELL 2
3
AN143.0
May 9, 2005
Application Note 143
Lot 1 continued
Voltage Output Error - Cell 3 (Lot 1)
Voltage Measurement Output Error - Cell 3
Lot 1
Output Error (V)
2.0%
20.0E-3
1.5%
15.0E-3
1.0%
10.0E-3
0.5%
0.0%
-0.5% 1
5.0E-3
000.0E+0
-5.0E-3 1
1.5
2
2.5
3
3.5
4
4.5
1.5
2
25degC
3
3.5
4
4.5
Input Voltage
Input Voltage (V)
0degC
2.5
-1.0%
0degC Average
0degC +3STD
0degC -3STD
50degC
FIGURE 4A.
25degC Average
25degC +3STD
25degC -3STD
50degC Average
50degC +3STD
50degC -3STD
FIGURE 4B.
FIGURE 4. INPUT TO OUTPUT VOLTAGE ERROR - CELL 3
Voltage Output Error - Cell 4 (Lot 1)
Output Error (V)
Voltage Measurement Output Error - Cell 4
Lot 1
25.0E-3
20.0E-3
15.0E-3
10.0E-3
5.0E-3
000.0E+0
1
1.5
2
2.5
3
3.5
4
4.5
1.4%
1.2%
1.0%
0.8%
0.6%
0.4%
0.2%
0.0%
-0.2% 1
1.5
2
0degC
25degC
2.5
3
3.5
4
4.5
Input Voltage
Input Voltage (V)
50degC
0degC Average
0degC +3STD
0degC -3STD
FIGURE 5A.
25degC Average
25degC +3STD
25degC -3STD
50degC Average
50degC +3STD
50degC -3STD
FIGURE 5B.
FIGURE 5. INPUT TO OUTPUT VOLTAGE ERROR - CELL 4
4
AN143.0
May 9, 2005
Application Note 143
Lot 2
Voltage Output Error - Cell 1 (Lot 2)
Output Error (V)
Voltage Measurement Output Error - Cell 1
Lot 2
5.0E-3
000.0E+0
-5.0E-3
1
1.5
2
2.5
3
3.5
4
4.5
-10.0E-3
-15.0E-3
2.0%
1.5%
1.0%
0.5%
0.0%
-0.5% 1
-1.0%
-1.5%
-2.0%
1.5
2
25degC
3
3.5
4
4.5
Input Voltage
Input Voltage (V)
0degC
2.5
0degC Average
0degC +3 STD
0degC -3 STD
50degC
FIGURE 6A.
25degC Average
25degC +3 STD
25degC -3 STD
50degC Average
50degC +3 STD
50degC -3 STD
FIGURE 6B.
FIGURE 6. INPUT TO OUTPUT VOLTAGE ERROR - CELL 1
Voltage Output Error - Cell 2 (Lot 2)
Output Error (V)
Voltage Measurement Output Error - Cell 2
Lot 2
10.0E-3
8.0E-3
6.0E-3
4.0E-3
2.0E-3
000.0E+0
-2.0E-3 1
1.00%
0.50%
0.00%
1.0
1.5
2.0
2.5
3.0
3.5
4.0
4.5
-0.50%
1.5
2
2.5
3
3.5
Input Voltage (V)
0degC
25degC
50degC
4
4.5
Input Voltage
0degC Average
0degC +3STD
0degC -3STD
25degC Average
25degC +3STD
25degC -3STD
50degC Average
50degC +3STD
50degC -3STD
FIGURE 7B.
FIGURE 7A.
FIGURE 7. INPUT TO OUTPUT VOLTAGE ERROR - CELL 2
5
AN143.0
May 9, 2005
Application Note 143
Lot 2 (Continued)
Voltage Output Error - Cell 3 (Lot 2)
Output Error (V)
Voltage Measurement Output Error - Cell 3
Lot 2
20.0E-3
15.0E-3
10.0E-3
5.0E-3
000.0E+0
-5.0E-3 1
-10.0E-3
2.0%
1.0%
0.0%
-1.0%
1.5
2
2.5
3
3.5
4
4.5
1
1.5
2
25degC
3
3.5
4
4.5
-2.0%
Input Voltage
Input Voltage (V)
0degC
2.5
0degC Average
0degC +3STD
0degC -3STD
50degC
FIGURE 8A.
25degC Average
25degC +3STD
25degC -3STD
50degC Average
50degC +3STD
50degC -3STD
FIGURE 8B.
FIGURE 8. INPUT TO OUTPUT VOLTAGE ERROR - CELL 3
Voltage Output Error - Cell 4 (Lot 2)
Output Error (V)
Voltage Measurement Output Error - Cell 4
Lot 2
20.0E-3
15.0E-3
10.0E-3
5.0E-3
000.0E+0
-5.0E-3 1
1.5
2
2.5
3
3.5
4
4.5
2.5%
2.0%
1.5%
1.0%
0.5%
0.0%
-0.5% 1
-1.0%
-1.5%
1.5
2
25degC
3
3.5
4
4.5
Input Voltage
Input Voltage (V)
0degC
2.5
50degC
0degC Average
0degC +3STD
0degC -3STD
25degC Average
25degC +3STD
25degC -3STD
50degC Average
50degC +3STD
50degC -3STD
FIGURE 9B.
FIGURE 9A.
FIGURE 9. INPUT TO OUTPUT VOLTAGE ERROR - CELL 4
6
AN143.0
May 9, 2005
Application Note 143
Lot 3
Voltage Output Error - Cell 1 (Lot 3)
Output Error (V)
Voltage Measurement Output Error - Cell 1
Lot 3
1.5%
1.0%
10.0E-3
0.5%
5.0E-3
0.0%
000.0E+0
-5.0E-3
1
1.5
2
2.5
3
3.5
4
4.5
-0.5%
1
1.5
2
2.5
3
3.5
4
4.5
-1.0%
-10.0E-3
Input Voltage
Input Voltage (V)
0degC
25degC
0degC Average
0degC +3 STD
0degC -3 STD
50degC
FIGURE 10A.
25degC Average
25degC +3 STD
25degC -3 STD
50degC Average
50degC +3 STD
50degC -3 STD
FIGURE 10B.
FIGURE 10. INPUT TO OUTPUT VOLTAGE ERROR - CELL 1
Voltage Output Error - Cell 2 (Lot 3)
Output Error (V)
Voltage Measurement Output Error - Cell 2
Lot 3
10.0E-3
5.0E-3
000.0E+0
-5.0E-3
1
1.5
2
2.5
3
3.5
4
4.5
1.5%
1.0%
0.5%
0.0%
-0.5%1.0
-1.0%
-1.5%
1.5
2.0
2.5
3.0
3.5
4.0
4.5
Input Voltage
-10.0E-3
Input Voltage (V)
0degC
25degC
50degC
0degC Average
0degC +3STD
0degC -3STD
FIGURE 11A.
25degC Average
25degC +3STD
25degC -3STD
50degC Average
50degC +3STD
50degC -3STD
FIGURE 11B.
FIGURE 11. INPUT TO OUTPUT VOLTAGE ERROR - CELL 2
7
AN143.0
May 9, 2005
Application Note 143
Lot 3 (Continued)
Voltage Output Error - Cell 3 (Lot 3)
Output Error (V)
Voltage Measurement Output Error - Cell 3
Lot 3
20.0E-3
10.0E-3
000.0E+0
1
1.5
2
2.5
3
3.5
4
4.5
-10.0E-3
2.0%
1.5%
1.0%
0.5%
0.0%
-0.5% 1
-1.0%
-1.5%
1.5
2
25degC
3
3.5
4
4.5
Input Voltage
Input Voltage (V)
0degC
2.5
0degC Average
0degC +3STD
0degC -3STD
50degC
FIGURE 12A.
25degC Average
25degC +3STD
25degC -3STD
50degC Average
50degC +3STD
50degC -3STD
FIGURE 12B.
FIGURE 12. INPUT TO OUTPUT VOLTAGE ERROR - CELL 3
Voltage Output Error - Cell 4 (Lot 3)
Output Error (V)
Voltage Measurement Output Error - Cell 4
Lot 3
15.0E-3
10.0E-3
5.0E-3
000.0E+0
-5.0E-3 1
1.5
2
2.5
3
3.5
-10.0E-3
4
4.5
2.0%
1.5%
1.0%
0.5%
0.0%
-0.5% 1
-1.0%
-1.5%
1.5
2
25degC
3
3.5
4
4.5
Input Voltage
Input Voltage (V)
0degC
2.5
50degC
0degC Average
0degC +3STD
0degC -3STD
FIGURE 13A.
25degC Average
25degC +3STD
25degC -3STD
50degC Average
50degC +3STD
50degC -3STD
FIGURE 13B.
FIGURE 13. INPUT TO OUTPUT VOLTAGE ERROR - CELL 4
8
AN143.0
May 9, 2005
Application Note 143
Combine All Lots
Voltage Output Error - Cell 1 (Lot All)
Output Error (V)
Voltage Measurement Output Error - Cell 1
Lot All
5.0E-3
000.0E+0
-5.0E-3
1
1.5
2
2.5
3
3.5
4
4.5
-10.0E-3
-15.0E-3
2.0%
1.5%
1.0%
0.5%
0.0%
-0.5% 1
-1.0%
-1.5%
-2.0%
1.5
2
2.5
3
3.5
4
4.5
Input Voltage
Input Voltage (V)
0degC
25degC
0degC Average
0degC +3 STD
0degC -3 STD
50degC
FIGURE 14A.
25degC Average
25degC +3 STD
25degC -3 STD
50degC Average
50degC +3 STD
50degC -3 STD
FIGURE 14B.
FIGURE 14. INPUT TO OUTPUT VOLTAGE ERROR - CELL 1
Voltage Output Error - Cell 2 (Lot All)
Output Error (V)
Voltage Measurement Output Error - Cell 2
Lot All
2.5%
2.0%
10.0E-3
1.5%
5.0E-3
0.5%
1.0%
0.0%
-0.5% 1.0
000.0E+0
1
1.5
2
2.5
3
3.5
-5.0E-3
4
4.5
1.5
2.0
2.5
3.0
3.5
4.0
4.5
-1.0%
-1.5%
Input Voltage
Input Voltage (V)
0degC
25degC
50degC
0degC Average
0degC +3STD
0degC -3STD
25degC Average
25degC +3STD
25degC -3STD
50degC Average
50degC +3STD
50degC -3STD
FIGURE 15B.
FIGURE 15A.
FIGURE 15. INPUT TO OUTPUT VOLTAGE ERROR - CELL 2
9
AN143.0
May 9, 2005
Application Note 143
Combine All Lots (Continued)
Voltage Output Error - Cell 3 (Lot All)
Output Error (V)
Voltage Measurement Output Error - Cell 3
Lot All
20.0E-3
15.0E-3
10.0E-3
5.0E-3
000.0E+0
-5.0E-3 1
-10.0E-3
1.5
2
2.5
3
3.5
4
4.5
2.0%
1.5%
1.0%
0.5%
0.0%
-0.5% 1
-1.0%
-1.5%
1.5
2
25degC
3
3.5
4
4.5
Input Voltage
Input Voltage (V)
0degC
2.5
0degC Average
0degC +3STD
0degC -3STD
50degC
FIGURE 16A.
25degC Average
25degC +3STD
25degC -3STD
50degC Average
50degC +3STD
50degC -3STD
FIGURE 16B.
FIGURE 16. INPUT TO OUTPUT VOLTAGE ERROR - CELL 3
Voltage Output Error - Cell 4 (Lot All)
Voltage Measurement Output Error - Cell 4
Lot All
2.0%
Output Error (V)
1.5%
20.0E-3
1.0%
15.0E-3
0.5%
0.0%
-0.5% 1
10.0E-3
5.0E-3
-5.0E-3 1
1.5
2
2.5
3
3.5
4
4.5
-1.0%
000.0E+0
1.5
2
2.5
3
3.5
4
4.5
-1.5%
Input Voltage
Input Voltage (V)
0degC
25degC
50degC
0degC Average
0degC +3STD
0degC -3STD
25degC Average
25degC +3STD
25degC -3STD
50degC Average
50degC +3STD
50degC -3STD
FIGURE 17B.
FIGURE 17A.
FIGURE 17. INPUT TO OUTPUT VOLTAGE ERROR - CELL 4
Intersil Corporation reserves the right to make changes in circuit design, software and/or specifications at any time without notice. Accordingly, the reader is cautioned to
verify that the Application Note or Technical Brief is current before proceeding.
For information regarding Intersil Corporation and its products, see www.intersil.com
10
AN143.0
May 9, 2005