WESTCODE An Date:- 30 Jun, 2004 Data Sheet Issue:- 1 IXYS Company Symmetrical Gate Turn-Off Thyristor Type S0700KC17# Absolute Maximum Ratings VOLTAGE RATINGS MAXIMUM LIMITS UNITS VDRM Repetitive peak off-state voltage, (note 1) 1700 V VDSM Non-repetitive peak off-state voltage, (note 1) 1800 V VRRM Repetitive peak reverse voltage 100-1360 V VRSM Non-repetitive peak reverse voltage 100-1360 V MAXIMUM LIMITS UNITS 700 A RATINGS ITGQ Peak turn-off current, (note 2) Ls Snubber loop inductance, ITM=ITGQ, (note 2) 0.3 µH IT(AVM) Mean on-state current, Tsink=55°C (note 3) 430 A IT(RMS) Nominal RMS on-state current, 25°C (note 3) 870 A ITSM Peak non-repetitive surge current tp=10ms 5 kA ITSM2 Peak non-repetitive surge current, (Note 4) 9 kA 2 2 125×10 3 2 It I t capacity for fusing tp=10ms As di/dtcr Critical rate of rise of on-state current, (note 5) 1000 PFGM Peak forward gate power 160 W PRGM Peak reverse gate power 5 kW IFGM Peak forward gate current 100 A VRGM Peak reverse gate voltage (note 6). 18 V toff Minimum permissible off-time, ITM=ITGQ, (note 2) 70 µs ton Minimum permissible on-time 20 µs Tj op Operating temperature range -40 to +125 °C Tstg Storage temperature range -40 to +150 °C A/µs Notes:1) VGK=-2Volts. 2) Tj=125°C, VD=80%VDM, VDM<VDRM, diGQ/dt=20A/µs, ITM=ITGQ & CS=1.5µF. 3) Double-side cooled, single phase; 50Hz, 180° half-sinewave. 4) Half-sinewave, tp=2ms 5) For di/dt>1000A/µs, consult factory. 6) May exceed this value during turn-off avalanche period. Data Sheet. Type S0700KC17# Issue 1 Page 1 of 15 July, 2004 WESTCODE An IXYS Company Symmetrical Gate Turn-Off Thyristor type S0700KC17# Characteristics Parameter MIN TYP MAX TEST CONDITIONS VTM Maximum peak on-state voltage - 1.9 2.2 IL Latching current - 5 IH Holding current. - dv/dtcr Critical rate of rise of off-state voltage IDM UNITS IG=1.5A, IT=700A V - Tj=25°C A 5 - Tj=25°C A 800 - - VD=80%VDRM, VGR=-2V V/µs Peak off state current - - 30 Rated VDRM, VGR=-2V mA IRM Peak reverse current - - 40 Rated VRRM mA IGKM Peak negative gate leakage current - - 200 VGR=-16V mA - 0.9 - Tj=-40°C V - 0.8 - Tj=25°C - 0.7 - Tj=125°C V - 1.5 6 Tj=-40°C A - 0.5 1 Tj=25°C - 125 400 Tj=125°C mA VD=50%VDRM, ITGQ=700A, IGM=12A, diG/dt=6A/µs µs - 0.8 - VGT IGT td Gate trigger voltage Gate trigger current Delay time V VD=25V, RL=25mΩ A VD=25V, RL=25mΩ Tj=25°C, di/dt=300A/µs, (10%IGM to 90%VD) tgt Turn-on time - 3 5 tf Fall time - 0.8 - Conditions as for td, (10%IGM to 10%VD) µs VD=50%VDRM, ITGQ=700A, CS=1.5µF, µs diGQ/dt=20A/µs, VGR=-16V, (90%ITGQ to 10%ITGQ) tgq Turn-off time - 10 11 Igq Turn-off gate current - 190 Qgq Turn-off gate charge - ttail Tail time tgw Gate off-time (see note 3). RthJK Thermal resistance junction to sink F Mounting force Wt Weight Conditions as for tf, (10%IGQ to 10%ITGQ) µs - Conditions as for tf A 1.3 1.45 Conditions as for tf mC - 30 50 Conditions as for tf, (10%ITGQ to ITGQ<1A) µs 100 - - Conditions as for tf µs - - 0.063 Double side cooled K/W - - 0.21 Cathode side cooled K/W - - 0.09 Anode side cooled K/W 4.5 - 9.0 (see note 2) - 120 - kN g Notes:o 1) Unless otherwise indicated Tj=125 C. 2) For other clamping forces, consult factory. 3) The gate off-time is the period during which the gate circuit is required to remain low impedance to allow for the passage of tail current. Data Sheet. Type S0700KC17# Issue 1 Page 2 of 15 July, 2004 WESTCODE An IXYS Company Symmetrical Gate Turn-Off Thyristor type S0700KC17# Notes on ratings and characteristics. 1. Maximum Ratings. 1.1 Off-state voltage ratings. Unless otherwise indicated, all off-state voltage ratings are given for gate conditions as diagram 1. For other gate conditions see the curves of figure 5. It should be noted that VDRM is the repeatable peak voltage which may be applied to the device and does not relate to a DC operating condition. While not given in the ratings, VDC should ideally be limited to 60% VDRM in this product. Diagram 1. 1.2 Reverse voltage rating. All devices in this series have a minimum VRRM of 100 Volts. If specified at the time of order, a VRRM up to 80%VDRM is available. 1.3 Peak turn-off current. The figure given in maximum ratings is the highest value for normal operation of the device under conditions given in note 2 of ratings. For other combinations of ITGQ, VD and Cs see the curves of figures 15 & 16. The curves are effective over the normal operating range of the device and assume a snubber circuit equivalent to that given in diagram 2. If a more complex snubber, such as an Underland circuit, is employed then the equivalent CS should be used and Ls<0.3µH must be ensured for the curves to be applied. Ls Ds R Cs Diagram 2. 1.4 R.M.S and average current. Measured as for standard thyristor conditions, double side cooled, single phase, 50Hz, 180° halfsinewave. These are included as a guide to compare the alternative types of GTO thyristors available, values can not be applied to practical applications, as they do not include switching losses. 2 1.5 Surge rating and I t. Ratings are for half-sinewave, peak value against duration is given in the curve of figure 4. 1.6 Snubber loop inductance. Use of GTO thyristors with snubber loop inductance, Ls<0.3µH implies no dangerous Vs voltages (see diagrams 2 & 3) can be applied, provided the other conditions given in note 1.3 are enforced. Alternatively Vs should be limited to 600 Volts to avoid possible device failure. Data Sheet. Type S0700KC17# Issue 1 Page 3 of 15 July, 2004 WESTCODE An IXYS Company Symmetrical Gate Turn-Off Thyristor type S0700KC17# 1.7 Critical rate of rise of on-state current The value given is the maximum repetitive rating, but does not imply any specific operating condition. The high turn-on losses associated with limit di/dt would not allow for practical duty cycle at this maximum condition. For special pulse applications, such as crowbars and pulse power supplies, a much higher di/dt is possible. Where the device is required to operate with infrequent high current pulses, with natural commutation (i.e. not gate turn-off), then di/dt>3kA/µs is possible. For this type of operation individual specific evaluation is required. 1.8 Gate ratings The absolute conditions above which the gate may be damaged. It is permitted to allow VGK(AV) during turnoff (see diagram 10) to exceed VRGM which is the implied DC condition. 1.9 Minimum permissible off time. This time relates specifically to re-firing of device (see also note on gate-off time 2.7). The value given in the ratings applies only to operating conditions of ratings note 2. For other operating conditions see the curves of figure 18. 1.10 Minimum permissible on-time. Figure is given for minimum time to allow complete conduction of all the GTO thyristor islands. Where a simple snubber, of the form given in diagram 1. (or any other non-energy recovery type which discharges through the GTO at turn-on) the actual minimum on-time will usually be fixed by the snubber circuit time constant, which must be allowed to fully discharge before the GTO thyristor is turned off. If the anode circuit has di/dt<10A/µs then the minimum on-time should be increased, the actual value will depend upon the di/dt and operating conditions (each case needs to be assessed on an individual basis). Data Sheet. Type S0700KC17# Issue 1 Page 4 of 15 July, 2004 WESTCODE An IXYS Company Symmetrical Gate Turn-Off Thyristor type S0700KC17# 2 Characteristics 2.1 Instantaneous on-state voltage Measured using a 500µs square pulse, see also the curves of figure 2 for other values of ITM. 2.2 Latching and holding current These are considered to be approximately equal and only the latching current is measured, type test only as outlined below. The test circuit and wave diagrams are given in diagram 4. The anode current is monitored on an oscilloscope while VD is increased, until the current is seen to flow during the un-gated period between the end of IG and the application of reverse gate voltage. Test frequency is 100Hz with IGM & IG as for td of characteristic data. IGM IG 200µs Gate current 15V 200µs Unlatched R1 Anode current unlatched condition CT C1 Anode current Latched condition Vs DUT Latched Gate-drive Diagram 4, Latching test circuit and waveforms. 2.3 Critical dv/dt The gate conditions are the same as for 1.1, this characteristic is for off-state only and does not relate to dv/dt at turn-off. The measurement, type test only, is conducted using the exponential ramp method as shown in diagram 5. It should be noted that GTO thyristors have a poor static dv/dt capability if the gate is open circuit or RGK is high impedance. Typical values: - dv/dt<30V/µs for RGK>10Ω. Diagram 5, Definition of dV/dt. 2.4 Off-state leakage. For IDRM & IRRM see notes 1.1 & 1.2 for gate leakage IGK, the off-state gate circuit is required to sink this leakage and still maintain minimum of –2 Volts. See diagram 6. Diagram 6. Data Sheet. Type S0700KC17# Issue 1 Page 5 of 15 July, 2004 WESTCODE An IXYS Company Symmetrical Gate Turn-Off Thyristor type S0700KC17# 2.5 Gate trigger characteristics. These are measured by slowly ramping up the gate current and monitoring the transition of anode current and voltage (see diagram 7). Maximum and typical data of gate trigger current, for the full junction temperature range, is given in the curves of figure 6. Only typical figures are given for gate trigger voltage, however, the curves of figure 1 give the range of gate forward characteristics, for the full allowable junction temperature range. The curves of figures 1 & 6 should be used in conjunction, when considering forward gate drive circuit requirement. The gate drive requirements should always be calculated for lowest junction temperature start-up condition. Feedback Anode current 0.9VAK R1 Not to scale Currentsence CT Gate current Vs C1 0.1IA IGT DUT Anode-Cathode Voltage Gate-drive Diagram 7, Gate trigger circuit and waveforms. 2.6 Turn-on characteristics The basic circuit used for turn-on tests is given in diagram 8. The test is initiated by establishing a circulating current in Tx, resulting in VD appearing across Cc/Lc. When the test device is fired Cc/Lc discharges through DUT and commutates Tx off, as pulse from Cc/Lc decays the constant current source continues to supply a fixed current to DUT. Changing value of Cc & Lc allows adjustment of ITM and di/dt respectively, VD and i are also adjustable. Lc Cc R1 CT Tx i D Cd Vd DUT Gate-drive Diagram 8, Turn-on test circuit of FT40. The definitions of turn-on parameters used in the characteristic data are given in diagram 9. The gate circuit conditions IGM & IG are fully adjustable, IGM duration 10µs. diG/dt IG IGM td tr di/dt ITM VD VD=VDM tgt Eon integral period Diagram 9, Turn-on wave-diagrams. Data Sheet. Type S0700KC17# Issue 1 Page 6 of 15 July, 2004 WESTCODE An IXYS Company Symmetrical Gate Turn-Off Thyristor type S0700KC17# In addition to the turn-on time figures given in the characteristics data, the curves of figure 9 give the relationship of tgt to di/dt and IGM. The data in the curves of figures 7 & 8, gives the turn-on losses both with and without snubber discharge, a snubber of the form given in diagram 2 is assumed. Only typical losses are given due to the large number of variables which effect Eon. It is unlikely that all negative aspects would appear in any one application, so typical figures can be considered as worst case. Where the turnon loss is higher than the figure given it will in most cases be compensated by reduced turn-off losses, as variations in processing inversely effect many parameters. For a worst case device, which would also have the lowest turn-off losses, Eon would be 1.5x values given in the curves of figures 7 & 8. Turn-on losses are measured over the integral period specified below:10 µs Eon = ∫ iv.dt 0 The turn-on loss can be sub-divided into two component parts, firstly that associated with tgt and secondly the contribution of the voltage tail. For this series of devices tgt contributes 50% and the voltage tail 50% (These figures are approximate and are influenced by several second order effects). The loss during tgt is greatly affected by gate current and as with turn-on time (figure 9), it can be reduced by increasing IGM. The turn-on loss associated with the voltage tail is not effected by the gate conditions and can only be reduced by limiting di/dt, where appropriate a turn-on snubber should be used. In applications where the snubber is discharged through the GTO thyristor at turn-on, selection of discharge resistor will effect Eon. The curves of figure 8 are given for a snubber as shown in diagram 2, with R=5Ω, this is the lowest recommended value giving the highest Eon, higher values will reduce Eon. 2.7 Turn-off characteristics The basic circuit used for the turn-off test is given in diagram 10. Prior to the negative gate pulse being applied constant current, equivalent to ITGQ, is established in the DUT. The switch Sx is opened just before DUT is gated off with a reverse gate pulse as specified in the characteristic/data curves. After the period tgt voltage rises across the DUT, dv/dt being limited by the snubber circuit. Voltage will continue to rise across DUT until Dc turns-on at a voltage set by the active clamp Cc, the voltage will be held at this value until energy stored in Lx is depleted, after which it will fall to VDC .The value of Lx is selected to give required VD Over the full tail time period. The overshoot voltage VDM is derived from Lc and forward voltage characteristic of DC, typically VDM=1.2VD to 1.5VD depending on test settings. The gate is held reverse biased through a low impedance circuit until the tail current is fully extinguished. Lc Dc Sx RL Rs Lx Cc i DX Vd Ds CT Cs Gatedrive Vc Cd DUT RCD snubber Diagram 10, Turn-off test circuit. The definitions of turn-off parameters used in the characteristic data are given in diagram 11. Data Sheet. Type S0700KC17# Issue 1 Page 7 of 15 July, 2004 WESTCODE An IXYS Company Symmetrical Gate Turn-Off Thyristor type S0700KC17# tgq tf VDM 0.9 ITGQ VD 0.1 VGR 0.1 QGQ VG(AV) VGQ IGQ tgw Diagram 11, Turn-off parameter definitions. In addition to the turn-off figures given in characteristic data, the curves of figures 10, 11 & 12 give the relationship of IGQ QGQ and tgq to turn-off current (ITGQ) and diGQ/dt. Only typical values of IGQ are given due to a great dependence upon the gate circuit impedance, which is a function of gate drive design not the device. The tgq is also, to a lesser extent, affected by circuit impedance and as such the maximum figures given in data assume a good low impedance circuit design. The curves of figures 17 & 18 give the tail time and minimum off time to re-fire device as a function of turn-off current. The minimum off time to re-fire the device is distinct from tgw, the gate off time given in characteristics. The GTO thyristor may be safely retriggered when a small amount of tail current is still flowing. In contrast, the gate circuit must remain low impedance until the tail current has fallen to zero or below a level which the higher impedance VGR circuit can sink without being pulled down below –2 Volts. If the gate circuit is to be switched to a higher impedance before the tail current has reached zero then the requirements of diagram 12 must be applied. i tail R (VGR - itail R)>2V Diagram 12. VGR The figure tgw, as given in the characteristic data, is the maximum time required for the tail current to decay to zero. The figure is applicable under all normal operating conditions for the device; provided suitable gate drive is employed. At lower turn-off current, or with special gate drive considerations, this time may be reduced (each case needs to be considered individually).Typical turn-off losses are given in the curves of figures 13 & 14, the integration period for the losses is nominally taken to the end of the tail time (Itail<1A) i.e. :tgt + ttail Eoff = ∫ iv.dt. 0 Data Sheet. Type S0700KC17# Issue 1 Page 8 of 15 July, 2004 WESTCODE An IXYS Company Symmetrical Gate Turn-Off Thyristor type S0700KC17# The curves of figure 13 give the turn-off energy for a fixed VD with a VDM=120%VD, whereas the curves of figure 14 give the turn-off energy with a fixed value of VDM and VD=50%VDRM. The curves are for energy against turn-off current/snubber capacitance with a correction for voltage inset as an additional graph (snubber equivalent to diagram 2 is assumed). From these curves a typical value of turn-off energy for any combination of ITGQ/Cs and VD or VDM can be derived. Only typical data is included, to allow for the tradeoff with on-state voltage (VTM) which is a feature of these devices, see diagram 13. When calculating losses in an application, the use of a maximum VTM and typical Eoff will (under normal operating frequencies) give a more realistic value. The lowest VTM device of this type would have a maximum turnoff energy of 1.5x the figure given in the curves of figures 13 & 14. Trade-off between VTM & Eoff E off Diagram 13. VTM 2.8 Safe turn-off periphery The necessity to control dv/dt at tun-off for the GTO thyristor implies a trade-off between ITGQ/VDM/Cs. This information is given in the curves of figures 15 & 16. The information in these curves should be considered as maximum limits and not implied operating conditions, some margin of 'safety' is advised with the conditions of the curves reserved for occasional excursions. It should be noted that these curves are derived at maximum junction temperature, however, they may be applied across the full operating temperature range of the device provided additional precautions are taken. At very low temperature, (below –10°C) the fall-time of device becomes very rapid and can give rise to very high turn-off voltage spikes, as such it is advisable to reduce snubber loop inductance to <0.2µH to minimise this effect. Data Sheet. Type S0700KC17# Issue 1 Page 9 of 15 July, 2004 WESTCODE An IXYS Company Symmetrical Gate Turn-Off Thyristor type S0700KC17# Curves Figure 1 – Forward gate characteristics Figure 2 - On-state characteristics of Limit device 1000 10000 S0700KC17# Issue 1 o S0700KC17# Issue 1 o Instantaneous on-state current, I T (A) Instantaneous forward gate current, I FG (A) For Tj= -40 C to +125 C 100 Minimum Maximum 10 1 0.00 0.50 1.00 1.50 1000 Tj=125oC o Tj=25 C 100 10 2.00 1 Instantaneous forward gate voltage, VFG (V) 2 3 Instantaneous on state voltage, VT (V) 4 2 Figure 3 - Maximum surge and I t Ratings S0700KC17# Issue 1 2 Tj (initial) = 125°C Total peak half sine surge current (A) 1.00E+06 I t: VRRM ≤10V I2t: 60% VRRM 1.00E+05 10000 Maximum I2t (A2s) 100000 ITSM: VRRM ≤10V ITSM: 60% VRRM 1000 1 3 5 10 Duration of surge (ms) Data Sheet. Type S0700KC17# Issue 1 1 5 10 50 100 1.00E+04 Duration of surge (cycles @ 50Hz) Page 10 of 15 July, 2004 WESTCODE An IXYS Company Symmetrical Gate Turn-Off Thyristor type S0700KC17# Figure 5 – Typical forward blocking voltage Vs. external gate-cathode resistance Figure 4 – Transient thermal impedance 1 1.2 S0700KC17# Issue 1 S0700KC17# Issue 1 Tj=25oC 1 Forward blocking as a ratio of V D/VDRM Thermal impedance junction to sink R thJK, (K/W) Cathode Anode 0.1 Double-side 0.01 Tj=100oC 0.8 0.6 0.4 Tj=125oC 0.2 RGK 0 0.001 0.001 0.01 0.1 1 10 1 100 10 100 External gate cathode resistance, RGK (Ω Ω) Time, (s) Figure 7 – Typical turn-on energy per pulse (excluding snubber discharge) Figure 6 – Gate trigger current 10 1000 50 S0700KC17# Issue 1 S0700KC17# Issue 1 VD=0.5VDRM di/dt=500A/µs IGM=12A, diG/dt=6A/µs Tj=25oC Turn-on energy per pulse, E ON (J). D.C. Gate trigger current, I GT (A) 40 1 Maximum Typical 0.1 di/dt=300A/µs 30 di/dt=100A/µs 20 10 0 0.01 0 -50 -25 0 25 50 75 100 125 150 300 600 900 1200 Turn-on current, ITM (A) Junction temperature, Tj (°C) Data Sheet. Type S0700KC17# Issue 1 Page 11 of 15 July, 2004 WESTCODE An IXYS Company Symmetrical Gate Turn-Off Thyristor type S0700KC17# Figure 8 – Typical turn-on energy per pulse (including snubber discharge) Figure 9 – Maximum turn-on time 8 0.3 S0700KC17# Issue 1 VD=0.5VDRM, IT=600A S0700KC17# Issue 1 di/dt=500A/µs VD=0.5VDRM tr of IGM ≤2µs IGM=12A, diG/dt=6A/µs 0.25 IGM=8A Tj=25oC Cs=1.5µF, Rs=5Ω IGM=12A di/dt=300A/µs o Tj=25 C 0.2 IGM=20A di/dt=100A/µs Turn-on time, t gt (µs) Turn-on energy per pulse, E ON (J) 6 0.15 4 0.1 2 0.05 0 0 0 300 600 900 1200 10 100 Turn-on current, ITM (A) 1000 Rate of rise of on-state current, di/dt (A/µs) Figure 10 – Typical peak turn-off gate current Figure 11 – Maximum gate turn-off charge 2 300 S0700KC17# Issue 1 S0700KC17# Issue 1 VD=0.8VDRM VD=0.8VDRM diGQ/dt=20A/µs o Tj=125oC Tj=125 C diGQ/dt=40A/µs diGQ/dt=30A/µs 250 1.5 Gate turn-off charge, Q GQ (mC) Peak turn-off gate current, I GQ (A) diGQ/dt=30A/µs diGQ/dt=20A/µs 200 150 diGQ/dt=40A/µs 1 0.5 100 QGQ 50 0 0 200 400 600 800 1000 Turn-off current, ITGQ (A) Data Sheet. Type S0700KC17# Issue 1 0 200 400 600 800 1000 Turn-off current, ITGQ (A) Page 12 of 15 July, 2004 WESTCODE An IXYS Company Symmetrical Gate Turn-Off Thyristor type S0700KC17# Figure 12 – Maximum turn-off time Figure 13 – Turn-off energy per pulse 20 0.6 S0700KC17# Issue 1 S0700KC17# Issue 1 VD=0.8VDRM VD=800V, VDM=1.28VD o Tj=125 diGQ/dt=20A/µs, Ls≤0.3µH Tj=125oC diGQ/dt=15A/µs Cs=1µF Cs=1.5µF Cs=2µF 15 Cs=0.5µF 10 Turn-off energy per pulse, E off (J) Turn-off time, t gq (µs) diGQ/dt=20A/µs diGQ/dt=30A/µs diGQ/dt=40A/µs Cs=3µF 0.4 VDM VD For other values of VD scale Eoff 2 1 0.2 0 200 800 1400 VDM 5 0 0 0 200 400 600 Turn-off current, ITGQ (A) 800 0 1000 200 Figure 14 – Typical turn-off energy per pulse 3 S0700KC17# Issue 1 800 1000 S0700KC17# Issue 1 VDM=1200V, VD=0.5VDRM VD=0.8VDRM VD=0.65VDRM VD≤0.5VDRM diGQ/dt=20A/µs diGQ/dt=20A/µs, Ls≤0.3µH Ls≤0.3µH Tj=125oC Tj=125oC 2.5 Cs=1µF 600 Figure 15 – Maximum permissible turn-off current 0.8 0.6 400 Turn-off current, ITGQ (A) Cs=1.5µF Cs=2µF Cs=3µF Snubber capacitance, Cs (µF) Turn-off energy per pulse, Eoff (J) Cs=0.5µF Note: VDM≤VDRM VDM VD 0.4 For other values of VDM scale Eoff 1.5 2 VDM≤1.2VD VD 1.5 1 1 0.5 600 0.2 1200 1800 VDM 0.5 0 0 0 200 400 600 800 1000 Data Sheet. Type S0700KC17# Issue 1 0 200 400 600 800 1000 Turn-off current, ITGQ (Amperes) Turn-off current, ITGQ (A) Page 13 of 15 July, 2004 WESTCODE An IXYS Company Symmetrical Gate Turn-Off Thyristor type S0700KC17# Figure 16 – Maximum turn-off current Figure 17 – Maximum tail time 1000 55 S0700KC17# Issue 1 V DM ≤1.2V D VD VD=0.8VDRM Cs=3µF 800 Tj=125oC Tail time (measured to I TGQ <1A), t tail (µs) Cs=2.2µF Turn-off current, I TGQ (A) Cs=1.5µF 600 Cs=1µF 400 Cs=0.5µF 50 45 200 diGQ/dt=20A/µs Ls≤0.3µH o Tj=125 C S0700KC17# Issue 1 0 40 0 0.2 0.4 0.6 0.8 1 0 Turn-off voltage as a ratio of VD/VDRM 200 400 600 800 1000 Turn-off current, ITGQ (A) Figure 18 – Minimum off-time to re-fire device 80 S0700KC17# Issue 1 diGQ/dt=15A/µs Minimum off-time to re-fire device, toff (µs) VD=0.8VDRM diGQ/dt=20A/µs Tj=125oC 70 diGQ/dt=40A/µs 60 50 0 Data Sheet. Type S0700KC17# Issue 1 200 400 600 Turn-off current, ITGQ (A) Page 14 of 15 800 1000 July, 2004 WESTCODE An IXYS Company Symmetrical Gate Turn-Off Thyristor type S0700KC17# Outline Drawing & Ordering Information 101A287 ORDERING INFORMATION (Please quote 10 digit code as below) S0700 KC ♦♦ # Fixed Type Code Fixed Outline Code Fixed Voltage Code VDRM/100 17 VRRM Code as % of VDRM D=80, E=75, F=70, G=65,H=60, J=55, K=50, L=45, M=40, N=35, P=30, R=25, S=20, T=15, V=10, W=5 Typical order code: S0700KC17G – 1700V VDRM, VRRM=65%VDRM (1105V), 16.5mm clamp height capsule. IXYS Semiconductor GmbH Edisonstraße 15 D-68623 Lampertheim Tel: +49 6206 503-0 Fax: +49 6206 503-627 E-mail: [email protected] IXYS Corporation 3540 Bassett Street Santa Clara CA 95054 USA Tel: +1 (408) 982 0700 Fax: +1 (408) 496 0670 E-mail: [email protected] WESTCODE An IXYS Company www.westcode.com www.ixys.com Westcode Semiconductors Ltd Langley Park Way, Langley Park, Chippenham, Wiltshire, SN15 1GE. Tel: +44 (0)1249 444524 Fax: +44 (0)1249 659448 E-mail: [email protected] Westcode Semiconductors Inc 3270 Cherry Avenue Long Beach CA 90807 USA Tel: +1 (562) 595 6971 Fax: +1 (562) 595 8182 E-mail: [email protected] The information contained herein is confidential and is protected by Copyright. The information may not be used or disclosed except with the written permission of and in the manner permitted by the proprietors Westcode Semiconductors Ltd. © Westcode Semiconductors Ltd. In the interest of product improvement, Westcode reserves the right to change specifications at any time without prior notice. Devices with a suffix code (2-letter, 3-letter or letter/digit/letter combination) added to their generic code are not necessarily subject to the conditions and limits contained in this report. Data Sheet. Type S0700KC17# Issue 1 Page 15 of 15 July, 2004