110 kV MICROFOCUS X-RAY SOURCE L9631

110 kV
X-RAY MICROFOCUS X-RAY SOURCE
SOURCE L9631
Optimum for In-line X-ray Inspection System
FEATURES
●High Output: 800 µA (50 W)
It allows continuous maximum output.
●High Stability
●Serial Port Control (RS-232C)
One package of a sealed type X-ray tube, a high-voltage power
supply and a control function.
●Easy Handling
Fully operable from an external PC.
APPLICATIONS
●Non-destructive Inspection
●In-line X-ray Inspection
●X-ray CT
[Applicable Objects]
•Electronic component
•Printed circuit board
•Plastic component
•Metal component
•Food
•Beverage
•Medicine & drug
•Bioproduct
SPECIFICATIONS
GENERAL
Parameter
Input Voltage (AC)
Power Consumption (Max.)
Operating Ambient Temperature
Storage Temperature
Operating and Storage Humidity
Weight
Conformance Standards
Operation
High Voltage Power Supply
Description / Value
100 to 240 (100 V / 200V Automatic Selection),
50 Hz / 60 Hz
240
+10 to +40
0 to +50
Below 85 (No Condensation)
Approx. 10
CE EMC: IEC 61326-1, Group1, Class A
Safety: IEC 61010-1
Continuous
Built-in
Unit
Description / Value
Sealed Type
Convection Cooling
Beryllium / 200
Tungsten
40 to 110
10 to 800 (50 W Max.)
50
15 to 80
62
16.8
Unit
—
—
µm
—
kV
µA
W
µm
degrees
mm
Description
Tube Voltage and Tube Current Preset / Auto Warm-up
Interlock
RS-232C
Windows® 2000 Professional, XP Professional
CPU: Intel Pentium or Higher, Memory: 64 MB or More
Unit
—
—
—
—
—
[
]
V
W
°C
°C
%
kg
—
—
—
X-RAY TUBE
Parameter
X-ray Tube
X-ray Tube Cooling Method
X-ray Tube Window Material / Thickness
Target Material
Tube Voltage Operational Range
Tube Current Operational Range 1
Maximum Output
X-ray Focal Spot Size
X-ray Beam Angle (Max.)
Focus to Object Distance (FOD)
X-RAY CONTROL PART
Parameter
Function
Protection
External Control
Applicable OS
Computer Operating Conditions
NOTE: 1See the graph of the tube current operational range.
!
PRE-CAUTION TO USE
1. X-ray emitted from this device is harmful for human body. And it should be necessary for the operator to protect himself/herself from it.
2. During an operation, the X-ray tube unit should be installed in the X-ray shielded facility or area in order to avoid any X-ray leakage.
Also the interlock system in X-ray control unit should be always used in order to avoid any misoperation.
OPERATIONAL CAUTION
The product may be subject to governmental occupational radiation hazardous regulation therefore the necessary application must be field
according to the local regulation.
X-RAY FOCAL SPOT SIZE vs. OUTPUT
100
TUBE CURRENT OPERATIONAL RANGE
TLSOB0097EA
900
TLSOB0098EA
80
TUBE CURRENT (µA)
700
60
40
0
600
500
400
300
200
20
15
100
0
6
10
20
30
40
0
40
50
50
60
OUTPUT (W)
70
80
90
TUBE VOLTAGE (kV)
DIMENSIONAL OUTLINE (Unit: mm)
X-RAY FOCAL
SPOT
71 ± 1
175 ± 2
60 ± 1
4-M3 DEPTH 3
60 ± 0.5
FOD
16.8
X-RAY BEAM ANGLE
62 °
X-RAY FOCAL SPOT
INTERLOCK-2
POWER
X-RAY
RS-232C
220 ± 2
COOLING FAN
INTERLOCK-1
~AC 100–240 V
POWER
FUSE
T6. 3A/250V
GND
12
61
100 ± 0.5
350 ± 2
10
X-RAY FOCAL SPOT SIZE (µm)
800
GND
85 MIN.
(REFERENCE)*
4-M6 DEPTH 8
(MOUNTING
SCREW HOLES)
8
250 ± 0.5
* Connection cables aren't included.
TLSOA0089ED
100
110
RELATED PRODUCTS
X-RAY IMAGE INTENSIFIER CAMERA UNIT (4-inch Beryllium Window) C7876, C7876-10
TXPRF0005
The C7876 is an X-ray image intensifier camera unit ideal for non-destructive inspection of light-element materials and radiation imaging at low energy X-ray levels.
The C7876 remarkably improves X-ray transmittance at low energy X-ray levels by using a beryllium window instead of an aluminum window currently used for most X-ray
image intensifiers.
The results are sharp and clear, high contrast images taken in real time even at low
energy X-ray levels down to a few keV.
An Aluminum window type is also available.
X-RAY IMAGE INTENSIFIER DIGITAL CAMERA UNIT C7336-03
TIIF0170
The C7336-03 consist of a high resolution, high contrast 4-inch X-ray image intensifier
(X-ray I.I.) and a 1.45 megapixel digital CCD camera.
The X-ray I.I. used has a fixed field-of-view of 100 mm diameter and an input window
made of thin aluminum which is excellent in X-ray transmission and causes less scattering of X-rays. These features allow real-time detection at X-ray energy levels from
about 20 keV.
The 1.45 megapixel digital CCD camera captures high-quality images which are clearer than those taken with conventional analog cameras.
X-CUBE™ (COMPACT X-RAY CCD CAMERA) H8480, H8953, H8481
TAPPF0174
X-CUBE™ is a compact X-ray CCD camera designed for non-destructive inspection.
Using a general-purpose CCD chip mounted in a rugged but lightweight camera head,
X-CUBE™ makes X-ray imaging as easy as an ordinary CCD camera in handling.
FOS (Fiber optic plate coated with X-ray scintillator)
Left: H8480 Center: H8953 Right: H8481
The FOS is an optical device for X-ray imaging, fabricated by coating an X-ray scintillator material over a fiber optic plate consisting
of more than tens of million glass fibers each a few micrometers in diameter. The FOS provides higher sensitivity and resolution than
currently used sensitized paper films and also allows real-time digital radiography when directly coupled to a commercially available
CCD. The fiber optic plate used in the FOS has excellent X-ray absorption characteristics, so that X-rays penetrating the X-ray scintillator and directly entering the CCD are minimized to less than 1 %. This protects the CCD from the deterioration and increased noise
caused by X-ray irradiation, assuring a long service life and maintaining high image quality.
Various sizes and shapes of FOS are available to meet your particular needs, including tapered FOP types.
■Structure
TMCPF0072
Protection Film
Scintillator : CsI(Tl)
FOP
(Fiber optic plate)
2D Image-Device
Windows ® is a registered trademark of Microsoft Corporation in the United States and/or other countries.
Other product and software names mentioned herein may be either registered trademarks or trademarks of their respective owners.
Subject to local technical requirements and regulations, availability of products included in this promotional material may vary. Please consult with our sales office.
Information furnished by HAMAMATSU is believed to be reliable. However, no responsibility is assumed for possible inaccuracies or omissions. Specifications are
subject to change without notice. No patent rights are granted to any of the circuits described herein. ©2012 Hamamatsu Photonics K.K.
HAMAMATSU PHOTONICS K.K.
www.hamamatsu.com
HAMAMATSU PHOTONICS K.K., Electron Tube Division
314-5, Shimokanzo, Iwata City, Shizuoka Pref., 438-0193, Japan, Telephone: (81)539/62-5248, Fax: (81)539/62-2205
U.S.A.: Hamamatsu Corporation: 360 Foothill Road, P. O. Box 6910, Bridgewater. N.J. 08807-0910, U.S.A., Telephone: (1)908-231-0960, Fax: (1)908-231-1218 E-mail: [email protected]
Germany: Hamamatsu Photonics Deutschland GmbH: Arzbergerstr. 10, D-82211 Herrsching am Ammersee, Germany, Telephone: (49)8152-375-0, Fax: (49)8152-2658 E-mail: [email protected]
France: Hamamatsu Photonics France S.A.R.L.: 19, Rue du Saule Trapu, Parc du Moulin de Massy, 91882 Massy Cedex, France, Telephone: (33)1 69 53 71 00, Fax: (33)1 69 53 71 10 E-mail: [email protected]
United Kingdom: Hamamatsu Photonics UK Limited: 2 Howard Court, 10 Tewin Road Welwyn Garden City Hertfordshire AL7 1BW, United Kingdom, Telephone: 44-(0)1707-294888, Fax: 44(0)1707-325777 E-mail: [email protected]
North Europe: Hamamatsu Photonics Norden AB: Smidesvägen 12, SE-171-41 SOLNA, Sweden, Telephone: (46)8-509-031-00, Fax: (46)8-509-031-01 E-mail: [email protected]
TXPR1014E01
Italy: Hamamatsu Photonics Italia: S.R.L.: Strada della Moia, 1/E, 20020 Arese, (Milano), Italy, Telephone: (39)02-935 81 733, Fax: (39)02-935 81 741 E-mail: [email protected]
China: HAMAMATSU PHOTONICS (CHINA) Co., Ltd.: 1201 Tower B, Jiaming Center, No.27 Dongsanhuan Beilu, Chaoyang District, Beijing 100020, China, Telephone: (86)10-6586-6006, Fax: (86)10-6586-2866 E-mail: [email protected]
MAR. 2012 IP