V10905P - Hamamatsu

4
inch
/
2
inch
DUAL
MODE
X-RAY X-RAY IMAGE INTENSIFIER (X-RAY I.I.)
IMAGING V10905P
FEATURES
●Lithium ion battery (4 inch mode)
●Suitable for high magnification (2 inch mode)
●High resolution, high contrast
●Low distortion
●Attachable with various cameras (Analog, Digital etc.)
APPLICATIONS
●Non-destructive inspection
●Industrial X-ray CT
●In-line X-ray inspection
[Applicable Samples]
•Electronic components •Printed circuit boards
•Plastic components •Metal components
•Foods •Beverages •Medicines & drugs
X-ray Source
X-ray Tube Voltage (kV)
X-ray Tube Current (µA)
Geometric Magnification
Camera
Number of Multiplication Frames
Sealed Type
90
100
×4.5
1.45 megapixel digital CCD
100 (4.2 s)
SPECIFICATIONS
X-ray I.I.
Parameters
Input Window Material (Thickness)
Input Phosphor Material
Output Phosphor Material
Input Surface Field-of-view Size
4 inch mode
2 inch mode
Output Image Size
Resolution (on Input Surface) (Typ.)
4 inch mode
2 inch mode
Conversion Factor
Shading (Min.)
Contrast Ratio
Operating Ambient Temperature
Storage Temperature
Operating and Storage Humidity
Weight
Description / Value
Aluminum (t 0.5 mm)
CsI
P43 or equivalent
99
50
20
90
110
4.0
60
14
+10 to +40
-10 to +45
Below 85 % (no condensation)
Approx. 7.7
Unit
—
—
—
mm
mm
mm
Lp/cm
Lp/cm
cd/m2/µGy/s
%
—
°C
°C
—
kg
Description / Value
100 to 240
24
30
Approx. 0.5
Unit
V
V
VA
kg
Power Supply
Parameters
Input Voltage (AC)
Output Voltage (DC)
Power Consumption
Weight
IMAGING EXAMPLES
●BGA (4 inch mode)
(2 inch mode)
X-ray Source
Open Type
X-ray Tube Voltage (kV)
130
X-ray Tube Current (µA)
10
Geometric Magnification
×28
1.45 megapixel digital CCD
Camera
Number of Multiplication Frames
100 (4.2 s)
●LED (2 inch mode)
Open Type
X-ray Source
90
X-ray Tube Voltage (kV)
19
X-ray Tube Current (µA)
×56
Geometric Magnification
1.45 megapixel digital CCD
Camera
Number of Multiplication Frames
100 (4.2 s)
●Bonding wire (2 inch mode)
Open Type
X-ray Source
90
X-ray Tube Voltage (kV)
19
X-ray Tube Current (µA)
×50
Geometric Magnification
1.45 megapixel digital CCD
Camera
Number of Multiplication Frames
100 (4.2 s)
DIMENSIONAL OUTLINES (Unit: mm)
136.0 ± 0.5
X-ray I.I.
4-M6 DEPTH 15 (1)
ACCELERATING
HIGH-VOLTAGE
POWER SUPPLY
120.0 ± 0.5
(1) SCREW HOLE FOR EQUIPMENT INSTALLATION
(2) SCREW HOLE FOR OPTICAL SYSTEM INSTALLATION
(3) OUTPUT PHOSPHOR SCREEN
(4) OUTPUT GLASS t = 7 ± 0.2 mm nd =1.50 ± 0.02
(5) DISTANCE FROM REFERENCE PLANE TO
OPTICAL OUTPUT IMAGE PLANE
42
226 ± 2
205 ± 2
154 ± 1
REFERENCE
PLANE
2
60 ± 0.2
90°
164 ± 2
90°
45°
INPUT WINDOW
PROTECTION PLATE
(CARBON FIBER
REINFORCED PLASTIC)
60.0 ± 0.2
INPUT SURFACE
FIELD-OF-VIEW
(3)
45°
130 ± 2
3-M5 DEPTH 8
P.C.D. 115
CABLE LENGTH:
250 mm to 300 mm
4-M5 DEPTH 8 (2)
P.C.D. 150
(4)
25.0 ± 0.3 (5)
REFERENCE PLANE
DETAILS OF OUTPUT SECTION
TII A0073EA
140
130
Power Supply
98
110
DC POWER SUPPLY
40
DC
OUT
FRONT VIEW
AC IN
REAR VIEW
TXPRA0020EC
CONFIGURATION
X-RAY IMAGE INTENSIFIER
POWER SUPPLY
CABLE LENGTH 5 m
HIGH-VOLTAGE
POWER SUPPLY
DC POWER SUPPLY
AC 100 V to 240 V
30 VA
X-RAY
SOURCE
CABLE LENGTH 5 m
X-RAY IMAGE
INTENSIFIER
2-WIRE FOR FIELD OF VIEW SWITCHING CABLE
CCD
CONTROLLER
CAMERA CONTROLLER
CAMERA CABLE
SAMPLE
ON
ENHANCE
GAIN
OFFSET
POWER
AC 100 V to 240 V
OFF
Optional 10 m cables are also available.
CONFIGURATION
TXPRC0013EA
RELATED PRODUCTS (X-ray image intensifier camera units)
C7876 (4-inch beryllium input window)
The C7876 is the ideal choice for non-destructive inspection of light-element materials in the low-energy X-ray region and for radiation imaging.
The image intensifier input window utilizes beryllium instead of aluminum (Al) which
is mostly used. Using a beryllium window drastically improves X-ray transmittance in
the low-energy X-ray region for better imaging.
The internal structure of materials like thin plastic and aluminum can now be seen in
real-time with a high contrast that was impossible up till now.
Aluminum (Al) input windows are also available.
X-RAY IMAGE INTENSIFIER DIGITAL CAMERA UNIT C7336-05/-52
The C7336 series consist of a high resolution, high contrast 4-inch X-ray image intensifier (X-ray I.I.) and a 2.8 megapixel CMOS image sensor.
The X-ray I.I. used has a fixed field-of-view of 100 mm diameter or a 4 inches/2 inches adjustable field-of-view and an input window made of thin aluminum which is
excellent in X-ray transmission and causes less scattering of X-rays. These features
allow real-time detection at X-ray energy levels from about 20 keV.
The captured images can be transferred to PC directly by interface of IEEE1394b.
Subject to local technical requirements and regulations, availability of products included in this promotional material may vary. Please consult with our sales office.
Information furnished by HAMAMATSU is believed to be reliable. However, no responsibility is assumed for possible inaccuracies or omissions. Specifications are
subject to change without notice. No patent rights are granted to any of the circuits described herein. ©2014 Hamamatsu Photonics K.K.
HAMAMATSU PHOTONICS K.K.
www.hamamatsu.com
HAMAMATSU PHOTONICS K.K., Electron Tube Division
314-5, Shimokanzo, Iwata City, Shizuoka Pref., 438-0193, Japan, Telephone: (81)539/62-5248, Fax: (81)539/62-2205
U.S.A.: Hamamatsu Corporation: 360 Foothill Road, Bridgewater. N.J. 08807-0910, U.S.A., Telephone: (1)908-231-0960, Fax: (1)908-231-1218 E-mail: [email protected]
Germany: Hamamatsu Photonics Deutschland GmbH: Arzbergerstr. 10, D-82211 Herrsching am Ammersee, Germany, Telephone: (49)8152-375-0, Fax: (49)8152-2658 E-mail: [email protected]
France: Hamamatsu Photonics France S.A.R.L.: 19, Rue du Saule Trapu, Parc du Moulin de Massy, 91882 Massy Cedex, France, Telephone: (33)1 69 53 71 00, Fax: (33)1 69 53 71 10 E-mail: [email protected]
United Kingdom: Hamamatsu Photonics UK Limited: 2 Howard Court, 10 Tewin Road, Welwyn Garden City, Hertfordshire AL7 1BW, United Kingdom, Telephone: (44)1707-294888, Fax: (44)1707-325777 E-mail: [email protected]
North Europe: Hamamatsu Photonics Norden AB: Torshamnsgatan 35 SE-164 40 Kista, Sweden, Telephone: (46)8-509-031-00, Fax: (46)8-509-031-01 E-mail: [email protected]
TXPR1003E04
Italy: Hamamatsu Photonics Italia S.r.l.: Strada della Moia, 1 int. 6, 20020 Arese (Milano), Italy, Telephone: (39)02-93581733, Fax: (39)02-93581741 E-mail: [email protected]
China: Hamamatsu Photonics (China) Co., Ltd.: B1201 Jiaming Center, No.27 Dongsanhuan Beilu, Chaoyang District, Beijing 100020, China, Telephone: (86)10-6586-6006, Fax: (86)10-6586-2866 E-mail: [email protected]
SEPT. 2014 IP