Streak camera C10627 series Sweep frequency of 20 MHz ! Now make fluorescence lifetime measurements with higher sensitivity. Introducing the Streak camera C10627 with a maximum sweep frequency up to 20MHz, 10 times faster sweep provides 10 times the signal or 1/10 the acquisition time. Along with faster readout digital readout enables the Streak camera C10627 to capture weak, short-lifetime samples excited by a compact laser or even LEDs. Combined with the confocal microscope or scanning near-field optical microscope (SNOM), the Streak camera C10627 measures luminescence lifetime in extremely small regions and generates lifetime mapping for semiconductor or biological samples. Measurement example Time-Resolved Fluorescence Lifetime Measurement The measurement example for the standard sample with the PLP-10 as the excitation light source. A few to a few tens seconds accumulation required for the data acquisition per sample. [Sample] [Excitation wavelength] Zinc Tetraphenylporphyrin Ethanol solution Air-saturated 405 nm (PLP-10) Analysis result τ =1.97 ns Scaletype: Log10 Intensity 100 10-1 10-2 10-3 2.5 5.0 Time 7.5 10.0 ns Configuration example 1 Configuration example 2 Combination with PLP-10 Combination with a Microscope Streak camera C10627 Data analyzer Streak camera C10627 Data analyzer Spectrometer f=300 mm C11119-02 Spectrometer f=300 mm C11119-02 Spectrograph mount table A11350-11 Synchronous delay generator C10647-01 Standard optics A8110-01 or A8110-02 Synchronous delay generator C10647-01 Sample Laser Source Microscope Stage Controller Specifications Option Temporal resolution Sweep time Trigger jitter Trigger delay Maximum sweep repetition frequency (max.) Better than 15 ps (in single shot) 1 ns to 10 ms/ full scale Better than 20 ps Approx. 10 ns (fastest range) 20 MHz (1 ns range, 2 ns range) Spectral response characteristics 105 Spectrometer C11119-02 The Czerny-Turner Spectrometer C11119-02 with a focal length of 300 mm and F/4 provides highly efficient throughput to the streak camera by the use of an aberration-correction optical system. Includes a multiple-grating turret with more than 20 gratings* to choose from, integrated software control including entrance slit control. The Spectrograph mount table A11350-11 simplifies the coupling and alignment of the Spectrometer C11119-02 and the Streak camera C10627. * Higher resolution gratings may effect temporal resolution. Optics system Czerny-Turner type (with aberration-corrected toroidal mirror) Focal length 300 mm Aperture ratio F/4 Incident slit Variable between 10 μm and 3000 μm Grating mount Grating mount accommodates up to 3 gratings. (It is possible to add turret as an optional extra.) C10627-03 Quantum efficiency (μA/W) Standard Optics for Fiber Input Electric Stage PLP-10-xxx Sample holder for Laser diode head Organic chemistry sample M10306-xx A8114 or Sample holder for Semiconductor wafer A8113 Controller for PLP-10 C10196 Spectrograph mount table A11350-11 104 C10627-01 103 102 Spectrometer C11119-02 101 200 400 600 800 1000 1200 Wavelength (nm) ● ● Subject to local technical requirements and regulations, availability of products included in this promotional material may vary. Please consult your local sales representative. Information furnished by HAMAMATSU is believed to be reliable. However, no responsibility is assumed for possible inaccuracies or omissions. Specifications and external appearance are subject to change without notice. © 2015 Hamamatsu Photonics K.K. HAMAMATSU PHOTONICS K.K. www.hamamatsu.com HAMAMATSU PHOTONICS K.K., Systems Division 812 Joko-cho, Higashi-ku, Hamamatsu City, 431-3196, Japan, Telephone: (81)53-431-0124, Fax: (81)53-435-1574, E-mail: [email protected] U.S.A.: Hamamatsu Corporation: 360 Foothill Road, Bridgewater, N.J 08807, U.S.A., Telephone: (1)908-231-0960, Fax: (1)908-231-1218 E-mail: [email protected] Germany: Hamamatsu Photonics Deutschland GmbH.: Arzbergerstr. 10, D-82211 Herrsching am Ammersee, Germany, Telephone: (49)8152-375-0, Fax: (49)8152-265-8 E-mail: [email protected] France: Hamamatsu Photonics France S.A.R.L.: 19, Rue du Saule Trapu, Parc du Moulin de Massy, 91882 Massy Cedex, France, Telephone: (33)1 69 53 71 00, Fax: (33)1 69 53 71 10 E-mail: [email protected] United Kingdom: Hamamatsu Photonics UK Limited: 2 Howard Court,10 Tewin Road, Welwyn Garden City, Hertfordshire AL7 1BW, UK, Telephone: (44)1707-294888, Fax: (44)1707-325777 E-mail: [email protected] North Europe: Hamamatsu Photonics Norden AB: Torshamnsgatan 35 16440 Kista, Sweden, Telephone: (46)8-509-031-00, Fax: (46)8-509-031-01 E-mail: [email protected] Italy: Hamamatsu Photonics Italia S.r.l.: Strada della Moia, 1 int. 6 20020 Arese (Milano), Italy, Telephone: (39)02-93581733, Fax: (39)02-93581741 E-mail: [email protected] China: Hamamatsu Photonics (China) Co., Ltd.: B1201 Jiaming Center, No.27 Dongsanhuan Beilu, Chaoyang District, Beijing 100020, China, Telephone: (86)10-6586-6006, Fax: (86)10-6586-2866 E-mail: [email protected] Cat. No. SHSS0007E02 JUL/2015 HPK Created in Japan