TYPE APPROVAL CERTIFICATE Certificate No: E-14033 File No: 824.31 Job Id: 262.1-018572-1 This is to certify: That the Monitoring Relay with type designation(s) PGR-8800 (D1000) Issued to Littelfuse Selco A/S ROSKILDE, Denmark is found to comply with Det Norske Veritas' Rules for Classification of Ships, High Speed & Light Craft and Det Norske Veritas' Offshore Standards Application : Arc flash monitoring system for installation onboard ship and offshore units This Certificate is valid until 2019-06-30. Issued at Høvik on 2015-02-26 DNV GL local station: Copenhagen for DNV GL Digitally Signed By: Laumann, Marit Location: DNV GL Høvik, Norway Approval Engineer: Hanwee Low Signing Date: 2015-03-01 Marit Laumann Head of Section This Certificate is subject to terms and conditions overleaf. Any significant change in design or construction may render this Certificate invalid. The validity date relates to the Type Approval Certificate and not to the approval of equipment/systems installed. Form code: TA 1411a Revision: 2014-11 © DNV GL 2014. DNV GL and the Horizon Graphic are trademarks of DNV GL AS. www.dnvgl.com Page 1 of 3 Certificate No: E-14033 File No: 824.31 Job Id: 262.1-018572-1 Product description PGR-8800 Series (D1000): Arc Flash Monitoring System Type number PGR-8800 Description Main arc fault protection module Trip / Signal inputs and outputs Optical sensors Current sensors Digital input Output relay (2x contact sets with LED) Trip coil output Link USB interface 1x local sensor 6x inputs for external optical sensors (Point or Fiber-optic sensors) 3x phase current inputs 2x remote trip 2x inhibit 2x reset inputs 1x online 1x service 1x tripped 1x IGBT switch. Programmable to trip shunt or undervoltage circuit breaker Link up to 4x PGR-8800 modules via MODBUS RTU protocol (optional) Data logs and software configuration Power supply Rated supply voltage Ur Rated supply voltage Ur (Low voltage) Us variation Rated impulse withstand voltatge 100-240 V AC, 50-60 Hz or 110-250 V DC (may charge 24V DC external backup battery) 14-48 V DC or 24 V DC external backup battery AC 85% to110%, DC: 80% to 110 % 5 kV Environmental conditions -25 oC to +70 oC IP54 Operating temperature Dergee of protection Application/Limitation Installation of the unit is to be according to manufacturer's specifications. Type Approval documentation Technical Info: « PGR-8800 Arc-Flash Relay Manual, Document number: PM-1400-EN, Revision: 3-A-112913 » from Littelfuse. « PGR-8800 series (D1000) Arc-Flash Relay datasheet, Revision: 4-G-032714 » from Littelfuse. « D1000 firmware version history, Revision: 2014-10-13 » from Selco A/S. Test reports: DELTA Test Report no. DANAK-19/14491 dated 18-09-2014 Tests carried out Type/safety test in accordance to IEC 61010-1. Environment test according to IACS E10: Rev.5, Dec 2006 ‘Test Specification for Type Approval’. Power supply voltage variations, acoustic noise signals and compass safe distance test according to IEC 60945:2002 and IEC 60945:CORRIGENDUM 1:2008. Enclosure protection test according to IEC 60529:2001. Form code: TA 1411a Revision: 2014-11 www.dnvgl.com Page 2 of 3 Certificate No: E-14033 File No: 824.31 Job Id: 262.1-018572-1 Marking of product Littelfuse Selco A/S – Type designation Periodical assessment The scope of the periodical assessment is to verify that the conditions stipulated for the Type approval is complied with and that no alterations are made to the product design or choice of materials. The main elements of the periodical assessment are: · Inspection on factory samples, selected at random from the production line (where practicable) · Results from Production Sample Tests (PST) and Routines (RT) checked (if not available tests according to PST and RT to be carried out) · Review of type approval documentation · Review of possible change in design, materials and performance · Ensuring traceability between manufacturer’s product type marking and Type Approval Certificate. Periodical assessment to be performed at least every second year. END OF CERTIFICATE Form code: TA 1411a Revision: 2014-11 www.dnvgl.com Page 3 of 3