Marine - LBFS - DNV

Certificate No:
A-13885
File No:
895.30
Job Id:
262.1-012711-2
TYPE APPROVAL CERTIFICATE
This is to certify:
That the Level Switches
with type designation(s)
LBFS
Issued to
Baumer A/S
AABYHØJ, Denmark
is found to comply with
Det Norske Veritas' Rules for Classification of Ships, High Speed & Light Craft and Det Norske
Veritas' Offshore Standards
Application :
Location classes:
Temperature
Humidity
Vibration
EMC
Enclosure
D
B
B
B
B / IP67,
C / IP67.
See page 2
This Certificate is valid until 2016-06-30.
Issued at Høvik on 2014-08-27
DNV GL local station: Aalborg
for DNV GL
Digitally Signed By: Sneen, Ståle
Location: DNV GL Høvik, Norway
Approval Engineer: Andrzej Gdaniec
Signing Date: 2014-08-28, on behalf of
Odd Magne Nesvåg
Head of Section
This Certificate is subject to terms and conditions overleaf. Any significant change in design or construction may render this Certificate invalid.
The validity date relates to the Type Approval Certificate and not to the approval of equipment/systems installed.
If any person suffers loss or damage which is proven to have been caused by any negligent act or omission of the Society, then the Society shall
pay compensation to such person for his proven direct loss or damage. However, the compensation shall not exceed an amount equal to ten
times the fee charged for the service in question. The maximum compensation shall never exceed USD 2 million.
In this provision the “Society” shall mean DNV GL AS as well as all its direct and indirect owners, affiliates, subsidiaries, directors, officers,
employees, agents and any other person or entity acting on behalf of DNV GL AS.
Form code: TA 1411a
Revision: 2014-05
© DNV GL 2014. DNV GL and the Horizon Graphic are trademarks of DNV GL AS.
www.dnvgl.com
Page 1 of 3
Certificate No: A-13885
File No:
895.30
Job Id:
262.1-012711-2
Product description
Baumer Level Switch model LBFS, including the following variants:
Type designation:
LBFS abcd e (f)
a=
0
1
2
3
4
A
Standard
Ex ia IIC T5, ATEX II 1G (gas)
Ex ta IIIC T100 Da, ATEX II 1D (dust)
Ex nA II T5, ATEX II 3G
Ex ia IIC T5 (6) / Ex ta IIIC T100 da (2) (combined)
Standard, UL listed, E365692 (2)
b=
1
2
3
Plug, M12, plastic, with LED
Cable 5 m
Plug, M12, stainless steel, without LED
c=
1
2
3
4
5
6
7
A
B
G1/2”
G3/4”
G1”
G1/2” hygienic (for Accessories Universal) 3A / EHEDG
G1/2” for reverse assembly
3/4"NPT
M18x1
G½, DIN 3852 form E, NBR gasket
G½, DIN 3852 form E, FKM (Viton©) gasket
d=
1
2
Stainless Steel 1.4301 – AISI 304 (DNV Enclosure class B)
Stainless Steel 1.4404 – AISI 316 (DNV Enclosure class C)
e=
1
2
PNP output
NPN output
f=
0
C
No configuration
Configuration according to customer specifications
The switch has no movable parts due to electromagnetic detection principle and solid state outputs.
Approval conditions
The Type Approval covers hardware listed under Product description. When the hardware is used in applications to be
classed by DNV, documentation for the actual application is to be submitted for approval by the manufacturer of the
application system in each case. Reference is made to DNV Rules for Ships Pt.4 Ch.9 Control and Monitoring Systems.
Application/Limitation
LBFS casing material Stainless Steel 1.4404 (AISI 316) is required for use on open deck (DNV Enclosure class C).
The detection principle of the level switches is based on electromagnetic radiation in the range 100 MHz – 180 MHz.
The switches are to be applied for level detection in metallic enclosures (tanks, pipes, etc.) in order to satisfy the class
requirements for electromagnetic radiation.
Ex-certification is not covered by this certificate. Application in hazardous area to be approved in each case according to
the Rules and Ex-Certification/ Special Condition for Safe Use listed in valid Ex-certificate issued by a
notified/recognized Certification Body.
Type Approval documentation
Data sheet E21.01 EN/2014-05-12
Test reports:
Baumer no. 5505-091 Rev.C1 (EMC tests)
Baumer no. 5505-109 Rev.A1 (Electrical power supply failure test)
Baumer no. 5505-110 Rev.A1 (High Voltage test)
Form code: TA 1411a
Revision: 2014-05
www.dnvgl.com
Page 2 of 3
Certificate No: A-13885
File No:
895.30
Job Id:
262.1-012711-2
Baumer no. 5505-111 Rev.A1 (Humidity test)
Baumer no. 5505-112 Rev.A1 (Insulation resistance test)
Baumer no. 5505-113 Rev.A1 (Power supply variations test)
Baumer no. 5505-114 Rev.A1 (Temperature tests)
Baumer no. 5505-080 Rev.B1 (Vibration test)
DELTA no. DANAK-1911632 dated 2011-10-24 (Vibration and Shock tests)
DELTA no. DANAK-1911537 dated 2011-08-23 (IP67 Tightness test)
DELTA no. DANAK-1911536 dated 2011-08-23 (Salt mist test)
Tests carried out
Applicable tests according to Standard for Certification No. 2.4, April 2006.
Marking of product
Baumer
Type designation as listed under Product description
Unique serial number
Power ratings
Periodical assessment
The scope of the periodical assessment is to verify that the conditions stipulated for the type are
complied with, and that no alterations are made to the product design or choice of systems, software
versions, components and/or materials.
The main elements of the assessment are:
·
Ensure that type approved documentation is available
Inspection of factory samples, selected at random from the production line (where practicable)
·
·
Review of production and inspection routines, including test records from product sample tests and
control routines
Ensuring that systems, software versions, components and/or materials used comply with type
·
approved documents and/or referenced system, software, component and material specifications
·
Review of possible changes in design of systems, software versions, components, materials and/or
performance, and make sure that such changes do not affect the type approval given
Ensuring traceability between manufacturer’s product type marking and the type approval certificate
·
Periodical assessment is to be performed at least every second year and at renewal of this certificate.
END OF CERTIFICATE
Form code: TA 1411a
Revision: 2014-05
www.dnvgl.com
Page 3 of 3