Certificate No: A-13885 File No: 895.30 Job Id: 262.1-012711-2 TYPE APPROVAL CERTIFICATE This is to certify: That the Level Switches with type designation(s) LBFS Issued to Baumer A/S AABYHØJ, Denmark is found to comply with Det Norske Veritas' Rules for Classification of Ships, High Speed & Light Craft and Det Norske Veritas' Offshore Standards Application : Location classes: Temperature Humidity Vibration EMC Enclosure D B B B B / IP67, C / IP67. See page 2 This Certificate is valid until 2016-06-30. Issued at Høvik on 2014-08-27 DNV GL local station: Aalborg for DNV GL Digitally Signed By: Sneen, Ståle Location: DNV GL Høvik, Norway Approval Engineer: Andrzej Gdaniec Signing Date: 2014-08-28, on behalf of Odd Magne Nesvåg Head of Section This Certificate is subject to terms and conditions overleaf. Any significant change in design or construction may render this Certificate invalid. The validity date relates to the Type Approval Certificate and not to the approval of equipment/systems installed. If any person suffers loss or damage which is proven to have been caused by any negligent act or omission of the Society, then the Society shall pay compensation to such person for his proven direct loss or damage. However, the compensation shall not exceed an amount equal to ten times the fee charged for the service in question. The maximum compensation shall never exceed USD 2 million. In this provision the “Society” shall mean DNV GL AS as well as all its direct and indirect owners, affiliates, subsidiaries, directors, officers, employees, agents and any other person or entity acting on behalf of DNV GL AS. Form code: TA 1411a Revision: 2014-05 © DNV GL 2014. DNV GL and the Horizon Graphic are trademarks of DNV GL AS. www.dnvgl.com Page 1 of 3 Certificate No: A-13885 File No: 895.30 Job Id: 262.1-012711-2 Product description Baumer Level Switch model LBFS, including the following variants: Type designation: LBFS abcd e (f) a= 0 1 2 3 4 A Standard Ex ia IIC T5, ATEX II 1G (gas) Ex ta IIIC T100 Da, ATEX II 1D (dust) Ex nA II T5, ATEX II 3G Ex ia IIC T5 (6) / Ex ta IIIC T100 da (2) (combined) Standard, UL listed, E365692 (2) b= 1 2 3 Plug, M12, plastic, with LED Cable 5 m Plug, M12, stainless steel, without LED c= 1 2 3 4 5 6 7 A B G1/2” G3/4” G1” G1/2” hygienic (for Accessories Universal) 3A / EHEDG G1/2” for reverse assembly 3/4"NPT M18x1 G½, DIN 3852 form E, NBR gasket G½, DIN 3852 form E, FKM (Viton©) gasket d= 1 2 Stainless Steel 1.4301 – AISI 304 (DNV Enclosure class B) Stainless Steel 1.4404 – AISI 316 (DNV Enclosure class C) e= 1 2 PNP output NPN output f= 0 C No configuration Configuration according to customer specifications The switch has no movable parts due to electromagnetic detection principle and solid state outputs. Approval conditions The Type Approval covers hardware listed under Product description. When the hardware is used in applications to be classed by DNV, documentation for the actual application is to be submitted for approval by the manufacturer of the application system in each case. Reference is made to DNV Rules for Ships Pt.4 Ch.9 Control and Monitoring Systems. Application/Limitation LBFS casing material Stainless Steel 1.4404 (AISI 316) is required for use on open deck (DNV Enclosure class C). The detection principle of the level switches is based on electromagnetic radiation in the range 100 MHz – 180 MHz. The switches are to be applied for level detection in metallic enclosures (tanks, pipes, etc.) in order to satisfy the class requirements for electromagnetic radiation. Ex-certification is not covered by this certificate. Application in hazardous area to be approved in each case according to the Rules and Ex-Certification/ Special Condition for Safe Use listed in valid Ex-certificate issued by a notified/recognized Certification Body. Type Approval documentation Data sheet E21.01 EN/2014-05-12 Test reports: Baumer no. 5505-091 Rev.C1 (EMC tests) Baumer no. 5505-109 Rev.A1 (Electrical power supply failure test) Baumer no. 5505-110 Rev.A1 (High Voltage test) Form code: TA 1411a Revision: 2014-05 www.dnvgl.com Page 2 of 3 Certificate No: A-13885 File No: 895.30 Job Id: 262.1-012711-2 Baumer no. 5505-111 Rev.A1 (Humidity test) Baumer no. 5505-112 Rev.A1 (Insulation resistance test) Baumer no. 5505-113 Rev.A1 (Power supply variations test) Baumer no. 5505-114 Rev.A1 (Temperature tests) Baumer no. 5505-080 Rev.B1 (Vibration test) DELTA no. DANAK-1911632 dated 2011-10-24 (Vibration and Shock tests) DELTA no. DANAK-1911537 dated 2011-08-23 (IP67 Tightness test) DELTA no. DANAK-1911536 dated 2011-08-23 (Salt mist test) Tests carried out Applicable tests according to Standard for Certification No. 2.4, April 2006. Marking of product Baumer Type designation as listed under Product description Unique serial number Power ratings Periodical assessment The scope of the periodical assessment is to verify that the conditions stipulated for the type are complied with, and that no alterations are made to the product design or choice of systems, software versions, components and/or materials. The main elements of the assessment are: · Ensure that type approved documentation is available Inspection of factory samples, selected at random from the production line (where practicable) · · Review of production and inspection routines, including test records from product sample tests and control routines Ensuring that systems, software versions, components and/or materials used comply with type · approved documents and/or referenced system, software, component and material specifications · Review of possible changes in design of systems, software versions, components, materials and/or performance, and make sure that such changes do not affect the type approval given Ensuring traceability between manufacturer’s product type marking and the type approval certificate · Periodical assessment is to be performed at least every second year and at renewal of this certificate. END OF CERTIFICATE Form code: TA 1411a Revision: 2014-05 www.dnvgl.com Page 3 of 3