Surge Protection Module LED Lighting Surge Protection Module > LSP05GX Europe Version LSP05GX European Version Module Series RoHS Description Agency Approvals Agency Standard Agency File Number UL1449 for 240V only E320116 Applications • Outdoor and Commercial LED Lighting • Roadway lighting • Traffic lighting • Digital signage • Wall wash lighting • • • • Parking garage lighting Flood lighting Tunnel lighting Street lighting Additional Information Datasheet Resources Samples Littelfuse’s LSP05GX European version thermally protected Surge Protective Device is a self-protected device specially designed to be used in outdoor and commercial LED lighting fixtures for transient overvoltage protection. It has been developed with Littelfuse’s thermally protected varistor technology. Its built-in thermal disconnect function provides additional protection to prevent catastrophic failure and fire hazard even under extreme circumstances of varistor end-oflife or sustained over-voltage conditions. It also provides high line-to-earth/ground resistance, facilitating faster production line testing. LSP05GX series connected option allows clear indication of thermal fault protection by disconnecting power to the luminaire, thereby signaling SPD module replacement. The LSP05GX Surge Protective Device facilitates product compliance to IEEE C62.41.2 Location Category C Low. Features • Maximum Discharge Current 10kA, 8/20µs • Meets ANSI C136.2 Enhanced Level 10kV/5kA and IEEE C62.41.2 Location Category C Low Exposure • Thermally Protected Varistor technology • Parallel and Series Connected SPD Options • IP66 Water-proof and Dust-proof • UL1449 Recognized (240Vac voltage rating) • IEC61643-11 Class II/EN6164311 Type 2 Compliant1 • Compact form factor with mounting tabs • 240Vac and 277Vac are available for Class I and Class II installation based on IEC luminaire protection classes and are marked CE • Series connected – Varistor thermal protection indication by removal of power to luminaire • High line-to-earth/ ground resistance • RoHS compliant Notes: 1. Self-declared compliance. Absolute Maximum Ratings • For ratings of individual members of a series, see Device Ratings and Specifications chart LSP05GX Series Units Continous: Max AC Voltage Range (VM(AC)RMS) Continuous Current 275 to 320 V 5 A Transient: Maximum Discharge Current, 8/20μs Waveform (Imax) 10,000 A Nominal Discharge Current, 8/20µs Waveform (In) 5,000 A Operating Ambient Temperature Range (TA) -45 to +85 °C Storage Temperature Range (TSTG) -45 to +90 °C Isolation Voltage Capability (When the thermal disconnect opens) Insulation Resistance 600 V >1,000 MΩ CAUTION: Stresses above those listed in "Absolute Maximum Ratings" may cause permanent damage to the device. This is a stress only rating and operation of the device at these or any other conditions above those indicated in the operational sections of this specification is not implied. © 2015 Littelfuse, Inc. Specifications are subject to change without notice. Revised: 07/06/15 Surge Protection Module LED Lighting Surge Protection Module > LSP05GX Europe Version LSP05GX European Version Series Device Ratings & Specifications Part Number Parallel/ Series Operating Voltage (VAC) MCOV/UC1 (VAC) Maximum Discharge Current2 Imax (A) Nominal Discharge Current3 In (A) MLV4 (V) UP5 (V) LSP05G240PX3333 P 240 275 10,000 5,000 L-N:970 L-G:1410 N-G:1410 L-G:1600 N-G:1600 Safety Compliance IEC/ EN61643-116 Luminaire Class UL1449 I X II X L-N:1100 LSP05G240PX3316 P 240 275 10,000 5,000 L-N:970 L-G:1410 N-G:1410 L-N:1100 L-G:1600 N-G:1600 LSP05G240SX3333 S 240 275 10,000 5,000 L-N:970 L-G:1410 N-G:1410 L-N:1100 L-G:1600 N-G:1600 X I X LSP05G240SX3316 S 240 275 10,000 5,000 L-N:970 L-G:1410 N-G:1410 L-N:1100 L-G:1600 N-G:1600 X II X LSP05G277PX3333 P 277 320 10,000 5,000 L-N:1130 L-G:1410 N-G:1410 L-N:1200 L-G:1600 N-G:1600 I LSP05G277PX3316 P 277 320 10,000 5,000 L-N:1130 L-G:1410 N-G:1410 L-N:1200 L-G:1600 N-G:1600 II LSP05G277SX3333 S 277 320 10,000 5,000 L-N:1130 L-G:1410 N-G:1410 L-N:1200 L-G:1600 N-G:1600 X I LSP05G277SX3316 S 277 320 10,000 5,000 L-N:1130 L-G:1410 N-G:1410 L-N:1200 L-G:1600 N-G:1600 X II Glossary: 1. MCOV/UC: Maximum Continuous Operating Voltage - maximum r.m.s. voltage that could be continuously applied to the SPD. 2. Maximum Discharge Current Imax (A): The maximum discharge current is a measure of the SPDs maximum capability; single impulse of discharge current uses the 8/20µs current waveform. 3. Nominal Discharge Current In (A): The nominal discharge current is a measure of the SPDs endurance capability; 15 impulses of discharge current uses the 8/20µs current waveform. 4. MLV: UL1449 Measured limiting voltage; the highest value of residual voltage measurements during the application of impulses of 8/20µs nominal discharge current (In); an average voltage value of 15 impulses 5. Up: IEC 61643-11 Voltage protection level; the highest value of residual voltage measurements during the application of impulses of 8/20µs nominal discharge current (In); a rounding voltage value of maximum measurement. 6. Series module used in parallel connection for indication circuit connection. Notes: • It is normal practice to disconnect components that intentionally breakdown between Line and Protective Earth, otherwise the apparent leakage current measured by the Hi-Pot tester may incorrectly be judged a “failure.” • Maximum Discharge Current Imax (A): The maximum discharge current is a measure of the SPDs maximum capability; single impulse of discharge current uses the 8/20µs current waveform. All Devices pass maximum discharge current with possible, safe opening of thermal disconnect. Dimensions 26.0±1.5 Series Version 46.6±1.5 Ø4 28.6±1.5 .8± 0.5 100.0±20.0 Blue Brown Input Output Green with Yellow stripe Blue 37.0±1.5 Brown 46.1±1.5 100.0±20.0 Parallel Version 10.0±2.0 10.0±2.0 Ø4 .8± 26.0±1.5 0.5 46.6±1.5 Ø4 28.6±1.5 .8± 100.0±20.0 © 2015 Littelfuse, Inc. Specifications are subject to change without notice. Revised: 07/06/15 Blue Green with Yellow stripe 10.0±2.0 Ø4 .8± 0.5 46.1±1.5 Brown 37.0±1.5 Notes: 1. Brown: Line; Blue: Neutral; Green-Yellow Stripe: Earth/Ground. 2. Wire Gauge: AWG16 (1.31mm2), wire length: 100mm±20mm, wire stripping length:10±2mm. 3. Caution: Line/neutral wires must be correctly connected to AC power grid. Wiring error on line/neutral polarity may cause module failure. 0.5 Surge Protection Module LED Lighting Surge Protection Module > LSP05GX Europe Version Application/Installation Schematic L L N N LSP 05G 240 P N H Xxxxx + AC/DC Power - Supply G Part Numbering System LED Module Littelfuse Surge Protection Module 5kA (Nominal Discharge Current) SPD Parallel Connection L L N N P: Parallel connection S: Series connection + AC/DC Power Parallel Connection SPD (for Class II Unearthed) ~X3316 L L N N LED Module Blank: No Hi-Pot withstand capability in common mode H: With 1500Vac Hi-Pot withstand capability in common mode (L-G and N-G) Suffix Code: X3333: with GND wire connection, available for 240Vac and 277Vac rating with CE Marking for Class I earthed luminaire installation X3316: without GND wire connection, available for 240Vac and 277Vac rating with CE Marking for Class II unearthed luminaire installation + AC/DC Power - Supply LED Module Parallel Connection With LED indicating SPD status - ON (green): SPD is online - OFF: SPD needs replacement Blank: Waterproof IP66 N: Non-waterproof - Supply G G Operating Voltage ~X3333 LED normally on SPD ~X3333 R Notes: 1. Series module used in parallel connection for indication circuit connection. 2.LED indicator and associated circuitry are not included in the module. 3. Brown wire is AC line voltage (hot); blue wire is AC neutral voltage. 4. Brown wire voltage is cut off when SPD needs replacement. 5. R is current limiting resistor; it resistance/wattage is determined by AC line voltage and desired current driving LED. Example: AC line voltage 240V, LED: 1.6mA, resistor:150Kohm/0.5W. L L N N - LED Module SPD L N N AC/DC Power Supply G (for Class II Unearthed) + ~X3333 L Series Connection Power Supply G Series Connection AC/DC + - LED Module SPD ~X3316 © 2015 Littelfuse, Inc. Specifications are subject to change without notice. Revised: 07/06/15