Datasheet

Surge Protection Module
LED Lighting Surge Protection Module > LSP05G Europe Version
LSP05G European Version Module Series
RoHS
Description
Agency Approvals
Agency
Standard
Agency File Number
UL1449
E320116
Applications
• Outdoor and Commercial
LED Lighting
• Roadway lighting
• Traffic lighting
• Digital signage
• Wall wash lighting
•
•
•
•
Parking garage lighting
Flood lighting
Tunnel lighting
Street lighting
Additional Information
Datasheet
Resources
Samples
Littelfuse’s LSP05G European version thermally protected
Surge Protective Device is a self-protected device specially
designed to be used in outdoor and commercial LED lighting
fixtures for transient overvoltage protection. It has been
developed with Littelfuse’s thermally protected varistor
technology. Its built-in thermal disconnect function provides
additional protection to prevent catastrophic failure and fire
hazard even under extreme circumstances of varistor end-oflife or sustained over-voltage conditions. It also provides high
line-to-earth/ground resistance, facilitating faster production
line testing.
LSP05G series connected option allows clear indication
of thermal fault protection by disconnecting power to the
luminaire, thereby signaling SPD module replacement.
The LSP05G Surge Protective Device facilitates product
compliance to IEEE C62.41.2 Location Category C Low.
Features
• Maximum Discharge
Current 10kA, 8/20µs
• Meets ANSI C136.2
Enhanced Level 10kV/5kA
and IEEE C62.41.2 Location
Category C Low Exposure
• Thermally Protected
Varistor technology
• Parallel and Series
Connected SPD Options
• IP66 Water-proof
and Dust-proof
• UL1449 Recognized
• IEC 61643-11 Class II and EN
61643-11 Type 2 compliant.
• IEC CB Scheme Certificate
NL-37684 available for 240V
and NL-40516 for 277V
• Compact form factor
with mounting tabs
• 240Vac and 277Vac
are available for Class I
and Class II installation
based on IEC luminaire
protection classes
and are marked CE
• Series connected
– Varistor thermal
protection indication
by removal of power
to luminaire
• High line-to-earth/
ground resistance
• RoHS compliant
Absolute Maximum Ratings
• For ratings of individual members of a series, see Device Ratings and Specifications chart
LSP05G Series
Units
Continous:
Max AC Voltage Range (VM(AC)RMS)
Continuous Current
275 to 320
V
5
A
Transient:
Maximum Discharge Current, 8/20μs Waveform (Imax)
10,000
A
Nominal Discharge Current, 8/20µs Waveform (In)
5,000
A
Operating Ambient Temperature Range (TA)
-45 to +85
°C
Storage Temperature Range (TSTG)
-45 to +90
°C
Isolation Voltage Capability (When the thermal disconnect opens)
Insulation Resistance
600
V
>1,000
MΩ
CAUTION: Stresses above those listed in "Absolute Maximum Ratings" may cause permanent damage to the device. This is a stress only rating and operation of
the device at these or any other conditions above those indicated in the operational sections of this specification is not implied.
© 2016 Littelfuse, Inc.
Specifications are subject to change without notice.
Revised: 05/24/16
Surge Protection Module
LED Lighting Surge Protection Module > LSP05G Europe Version
LSP05G European Version Series Device Ratings & Specifications
Part Number
Parallel/
Series
Operating
Voltage
(VAC)
MCOV/UC1
(VAC)
Maximum
Discharge
Current2
Imax (A)
Nominal
Discharge
Current3
In (A)
MLV4
(V)
UP5
(V)
LSP05G240PX3333
P
240
275
10,000
5,000
L-N:970
L-G:1410
N-G:1410
L-G:1600
N-G:1600
Safety Compliance
IEC/
EN61643-116
Luminaire
Class
UL1449
I
X
II
X
L-N:1100
LSP05G240PX3316
P
240
275
10,000
5,000
L-N:970
L-G:1410
N-G:1410
L-N:1100
L-G:1600
N-G:1600
LSP05G240SX3333
S
240
275
10,000
5,000
L-N:970
L-G:1410
N-G:1410
L-N:1100
L-G:1600
N-G:1600
X
I
X
LSP05G240SX3316
S
240
275
10,000
5,000
L-N:970
L-G:1410
N-G:1410
L-N:1100
L-G:1600
N-G:1600
X
II
X
LSP05G277PX3333
P
277
320
10,000
5,000
L-N:1130
L-G:1410
N-G:1410
L-N:1200
L-G:1600
N-G:1600
I
X
LSP05G277PX3316
P
277
320
10,000
5,000
L-N:1130
L-G:1410
N-G:1410
L-N:1200
L-G:1600
N-G:1600
II
X
LSP05G277SX3333
S
277
320
10,000
5,000
L-N:1130
L-G:1410
N-G:1410
L-N:1200
L-G:1600
N-G:1600
X
I
X
LSP05G277SX3316
S
277
320
10,000
5,000
L-N:1130
L-G:1410
N-G:1410
L-N:1200
L-G:1600
N-G:1600
X
II
X
Glossary:
1. MCOV/UC: Maximum Continuous Operating Voltage - maximum r.m.s. voltage that could be continuously applied to the SPD.
2. Maximum Discharge Current Imax (A): The maximum discharge current is a measure of the SPDs maximum capability; single impulse of discharge current uses the 8/20µs
current waveform.
3. Nominal Discharge Current In (A): The nominal discharge current is a measure of the SPDs endurance capability; 15 impulses of discharge current uses the 8/20µs current waveform.
4. MLV: UL1449 Measured limiting voltage; the highest value of residual voltage measurements during the application of impulses of 8/20µs nominal discharge current (In);
an average voltage value of 15 impulses
5. Up: IEC 61643-11 Voltage protection level; the highest value of residual voltage measurements during the application of impulses of 8/20µs nominal discharge current (In);
a rounding voltage value of maximum measurement.
6. Series module used in parallel connection for indication circuit connection.
7. LSP05G240S & LSP05G277S are certified by DEKRA with below IEC 61643-11 specifications.
Parameter
Value
Unit
Temporary overvoltage TOV
LSP05G240S Specification
UT
337
V
LV system fault 255 V x 1.32 at tT = 5 s, TN power grid
Temporary overvoltage TOV
UT
442
V
LV system fault 255 V x 1.732 at tT = 120 min, TN power grid
Power grids
TN
Backup fuse
16
End of life indication
A
max., gG fuse
Optical, light ON: SPD is functional
Light OFF: SPD has reached end-of-life
yes
Max earth leakage current at Uc
Condition
50
µA
Parameter
Value
Unit
Temporary overvoltage TOV
UT
403
V
LV system fault 305 V x 1.32 at tT = 5 s, TN power grid
Temporary overvoltage TOV
UT
529
V
LV system fault 305 V x 1.732 at tT = 120 min, TN power grid
LSP05G277S Specification
Power grids
TN
Backup fuse
20
End of life indication
yes
A
Max. rms, to GND
Condition
max., gG fuse
Optical, light ON: SPD is functional
Light OFF: SPD has reached end-of-life
LSP05G Protection Levels Up
Ic 8/20 µS
5kA
LSP05G240S
Differential mode U2
970V
Common mode U1/U2
1600V/1410V
Ic 8/20 µS
5kA
LSP05G277S
Differential mode U2
1130V
Common mode U1/U2
1600V/1410V
Notes:
• It is normal practice to disconnect components that intentionally breakdown between Line and Protective Earth, otherwise the apparent leakage current measured by the Hi-Pot tester
may incorrectly be judged a “failure.”
• Maximum Discharge Current Imax (A): The maximum discharge current is a measure of the SPDs maximum capability; single impulse of discharge current uses the 8/20µs current
waveform. All Devices pass maximum discharge current with possible, safe opening of thermal disconnect.
© 2016 Littelfuse, Inc.
Specifications are subject to change without notice.
Revised: 05/24/16
Surge Protection Module
L
L
N
N
AC/DC > LSP05G Europe Version
LED Lighting Surge Protection Module
+
Power
-
Supply
G
LED Module
SPD
Parallel Connection
Dimensions
26.0±1.5
Series Version
46.6±1.5
Ø4
0.5
L
L
N
N
+
AC/DC
Power
-
Supply
G
28.6±1.5
.8±
~X3333
LED Module
100.0±20.0
Brown
Blue
Input
37.0±1.5
Brown
Output
Green with
Yellow stripe
Blue
46.1±1.5
100.0±20.0
Parallel Connection
SPD
(for Class II Unearthed)
~X3316
10.0±2.0
10.0±2.0
Ø4
L
L
N
N
26.0±1.5
0.5
Parallel Version
+
AC/DC
.8±
Power
-
Supply
G
LED Module
46.6±1.5
28.6±1.5
Ø4
.8
±0
.5
Parallel
Connection
100.0±20.0
Blue
Green with
Yellow stripe
10.0±2.0
Ø4
R
46.1±1.5
Brown
LED normally on
SPD
~X3333
37.0±1.5
Notes:
1. Brown: Line; Blue: Neutral; Green-Yellow Stripe: Earth/Ground.
2. Wire Gauge: AWG16 (1.31mm2), wire length: 100mm±20mm, wire stripping
length:10±2mm.
3. Caution: Line/neutral wires must be correctly connected to AC power grid.
Wiring error on line/neutral polarity may cause module failure.
With LED indicating SPD status
- ON (green): SPD is online
- OFF: SPD needs replacement
.8±
0.5
Application/Installation Schematic
L
L
N
N
+
AC/DC
Power
Supply
G
L
L
N
N
-
LED Module
SPD
L
L
N
N
+
AC/DC
Power
-
Supply
G
Parallel Connection
SPD
(for Class II Unearthed)
~X3316
L
L
N
N
G
Series Connection
~X3333
LED Module
LED Module
L
N
AC/DC
Power
Supply
G
+
-
LED Module
SPD
~X3316
+
AC/DC
Power
-
Supply
LED Module
Parallel Connection
With LED indicating SPD status
- ON (green): SPD is online
- OFF: SPD needs replacement
-
SPD
N
(for Class II Unearthed)
+
~X3333
L
Series Connection
Power
Supply
G
Parallel Connection
AC/DC
LED normally on
SPD
~X3333
R
Notes:
1. Series module used in parallel connection for indication circuit connection.
2.LED indicator and associated circuitry are not included in the module.
3. Brown wire is AC line voltage (hot); blue wire is AC neutral voltage.
4. Brown wire voltage is cut off when SPD needs replacement.
5. R is current limiting resistor; it resistance/wattage is determined by AC line voltage and desired current driving LED. Example: AC line voltage 240V, LED: 1.6mA, resistor:150Kohm/0.5W.
L
L
AC/DC
+
© 2016 Littelfuse, Inc.
Specifications are subject to change without notice.
Revised: 05/24/16
Surge Protection Module
LED Lighting Surge Protection Module > LSP05G Europe Version
Repetitive Surge Capability
100,000
SURGE CURRENT (A)
10,000
1,000
100
MODEL SIZE = 20mm
TA = -55oC TO 85 oC
130 to 625V M(AC) RATING
1
2
15
104
105
106
10 2
10 3
Pulse Rating
(8x20µSec)
Strikes
Surge
1
2
15
100
1,000
10,000A
7,000A
5,000A
1,500A
700A
∞
10
1
10
100
1,000
IMPULSE DURATION (μs)
10,000
Part Numbering System
LSP 05G 240 P N H Xxxxx
Littelfuse Surge Protection Module
5kA (Nominal Discharge Current)
Operating Voltage
P: Parallel connection
S: Series connection
Blank: Waterproof IP66
N: Non-waterproof
Blank: No Hi-Pot withstand capability in
common mode
H: With 1500Vac Hi-Pot withstand
capability in common mode (L-G and N-G)
© 2016 Littelfuse, Inc.
Specifications are subject to change without notice.
Revised: 05/24/16
Suffix Code:
X3333: with GND wire connection, available for 240Vac and 277Vac rating with
CE Marking for Class I earthed
luminaire installation
Wire Color: Line: Brown, Neutral: Blue,
Ground/P: Green with yellow stripe
X3316: without GND wire connection,
available for 240Vac and 277Vac rating
with CE Marking for Class II unearthed
luminaire installation
Wire Color: Line: Brown, Neutral: Blue