MA600xERU Datasheet

MA600ERU Series
4:1 Input, 6W DIP,
Single & Dual Output
DC/DC Converters
Electrical Specifications
Key Features:
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
• 6W Output Power
Input
Parameter
• 4:1 Input Voltage Range
Input Voltage Range
• 1,500 VDC Isolation
Input Start Voltage
• 17 Standard Models
Input Filter
• Efficiency to 88%
• Compact DIP Case
• -40°C to +85°C Operation
• Industry Standard Pin-Out
• Low Cost
Conditions
Min.
24 VDC Input
9.0
48 VDC Input 18.0
24 VDC Input
48 VDC Input
(Pi) Filter
Max.
36.0
75.0
9.0
18.0
Units
Max.
±2.0
±1.5
±0.5
±1.0
±5.0
25
80
100
500
±5.0
±0.03
140
Units
%
%
%
%
%
mV P - P
Max.
Units
VDC
M
pF
kHz
VDC
VDC
Output
Parameter
Output Voltage Accuracy
Output Voltage Balance
Line Regulation, See Note 1
Load Regulation
Cross Regulation
Ripple (20 MHz)
Noise (20 MHz), See Note 3
3.0 kV Isolation
Models
Available
Typ.
24.0
48.0
Transient Recovery Time, See Note 4
Transient Response Deviation
Temperature Coefficient
Output Over Voltage Protection
Output Short Circuit, See Note 5
Conditions
IOUT = 5% to 100%
Dual Outputs, Balanced Loads
VIN = Min to Max
IOUT = 5% to 100%
See Note 2
See Note 3
3.3, 5 VDC Output
All Other Outputs
Min.
Typ.
±1.0
±0.5
±0.2
±0.5
10
30
50
300
±3.0
25% Load Step Change
110
Continuous (Autorecovery)
mV P - P
µSec
%
%/°C
%
General
Parameter
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Switching Frequency
EMI Characteristics
Parameter
Radiated Emissions
Conducted Emissions
ESD
RS
EFT
Surge
CS
Voltage Dips
Conditions
60 Seconds
500 VDC
100 kHz/0.1V
Min.
1,500
1,000
Typ.
1,000
300
Standard
See Note 6
EN 55022
See Note 6
EN 55022
EN 61000-4-2
EN 61000-4-3
See Note 7
EN 61000-4-4
See Note 8
EN 61000-4-5
EN 61000-4-6
EN 61000-4-29
Level
Class A
Class A
Criteria B; ±4 kV Contact
Criteria A; 10V/m
Criteria B; ±2 kV
Criteria B; ±2 kV
Criteria A; 3 Vrms
Criteria B; 0% - 70%
Environmental
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Parameter
Operating Temperature Range
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Physical
Case Size
Case Material
Weight
Conditions
Ambient
Case
Min.
-40
Typ.
+25
-55
Free Air Convection
RH, Non-condensing
Max.
+85
+105
+125
Units
°C
°C
°C
95
%
See Mechanical Diagram (Page 4)
Aluminum Alloy
0.49 Oz (14g)
Reliability Specifications
Parameter
MTBF
Conditions
MIL HDBK 217F, 25°C, Gnd Benign
Min.
1.0
Typ.
Max.
Units
MHours
Conditions
24 VDC Input
48 VDC Input
1.5 mm From Case for 10 Sec
Min.
-0.7
-0.7
Typ.
Max.
50.0
100.0
300
Units
Absolute Maximum Ratings
Parameter
Input Voltage Surge (1 Sec)
Lead Temperature
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com
VDC
°C
www.micropowerdirect.com
Model Selection Guide
Input
Model
Number
Voltage (VDC)
Nominal
Range
Output
Current (mA)
Voltage
Full-Load No-Load (VDC)
Current
Current
(mA, Max)
(mA, Min)
Efficiency
(%, Typ)
Fuse
Reflected Capacitive
Ripple
Rating
Load
Current
Slow-Blow
(µF, Max)
(mA Typ)
(mA)
MA624S-03ERU
24
9.0 - 36.0
316
7
3.3
1,500
75
79
20.0
1,800
600
MA624S-05ERU
24
9.0 - 36.0
301
7
5.0
1,200
60
83
20.0
1,000
600
MA624S-12ERU
24
9.0 - 36.0
287
7
12.0
500
25
87
20.0
100
600
MA624S-15ERU
24
9.0 - 36.0
284
7
15.0
400
20
88
20.0
100
600
MA624S-24ERU
24
9.0 - 36.0
287
7
24.0
250
12
87
20.0
47
600
MA624D-05ERU
24
9.0 - 36.0
301
7
±5.0
±600
±30
83
20.0
470
600
MA624D-12ERU
24
9.0 - 36.0
287
7
±12.0
±250
±12
87
20.0
100
600
MA624D-15ERU
24
9.0 - 36.0
287
7
±15.0
±200
±10
87
20.0
100
600
MA624D-24ERU
24
9.0 - 36.0
287
7
±24.0
±125
±6.25
87
20.0
47
600
MA648S-03ERU
48
18.0 - 75.0
156
3
3.3
1,500
75
80
20.0
1,800
300
MA648S-05ERU
48
18.0 - 75.0
148
3
5.0
1,200
60
84
20.0
1,000
300
MA648S-12ERU
48
18.0 - 75.0
144
3
12.0
500
25
87
20.0
100
300
MA648S-15ERU
48
18.0 - 75.0
142
3
15.0
400
20
88
20.0
100
300
MA648S-24ERU
48
18.0 - 75.0
144
3
24.0
250
12
87
20.0
47
300
MA648D-05ERU
48
18.0 - 75.0
150
3
±5.0
±600
±30
83
20.0
470
300
MA648D-12ERU
48
18.0 - 75.0
144
3
±12.0
±250
±12
87
20.0
100
300
MA648D-15ERU
48
18.0 - 75.0
144
3
±15.0
±200
±10
87
20.0
100
300
Notes:
1. On dual output models, the line regulation for the -VOUT (pin 16) output is ±1.0% max.
2. Cross regulation is measured with the +VOUT (pin 14) set to 50% load and the -VOUT (pin 16)
varied from 10% to 100% load. The load on dual output models should not be unbalanced more
than 5%. If the load unbalance is greater than 5%, the unit may not meet all specifications.
3. When measuring output ripple & noise, it is recommended that an external capacitor
(1 µF to 10 µF) be placed from the +VOUT to the -VOUT pins for single output units and from each
output to common for dual output models..
4. Transient recovery is measured to within a 1% error band for a load step change of 25%.
5. Short circuit protection is provided by a “hiccup mode” circuit.
6. All units are rated for EN 55022 (CE/RE) class A without external components. They will meet
class B with the addition of a discrete filter circuit as shown on page 3. Contact the factory for
more information this circuit or one of our filter/surge suppression modules.
7. To meet the requirements of EN 61000-4-4 (±2 kV) external components are needed, as
shown on page 3. Contact the factory for more information this circuit or one of our filter/
surge suppression modules.
8. To meet the requirements of EN 61000-4-5 (±2 kV), external components are needed. This can
be done discretely as shown on page 3. Contact the factory for more information this circuit
or one of our filter/surge suppression modules.
9. These units should not be operated with a load under 5% of full load. Operation at no-load will
not damage the unit, but they may not meet all specifications.
10. It is recommended that a fuse be used on the input of a power supply for protection. See the
Model Selection table above for the correct rating.
Efficiency vs Input Voltage: 48 VDC Input
292 Page Street Ste D Stoughton, MA 02072
Derating Curve
Efficiency vs Output Load: 48 VDC Input
• TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected]
Typical Connection
www.micropowerdirect.com
The diagram above illustrates a typical connection of the MA600ERUI series 5. Recommended values for components are:
for applications that require meeting EMC standards. The units do not require
Component
48 VIN
24 VIN
external components to operate as specified. Some notes on this diagram
MOV
S14K35
S14K60
(starting with the input circuit) are:
330 µF/50V
330 µF/100V
C1
1. It is recommended that an external fuse be used. The recommended fuse is
shown in the model chart on page 2.
1.0 µF/50V
1.0 µF/100V
C2
2. An external MOV is recommended on the input to protect the unit in the event
4.7 µH
4.7 µH
LDM1
of a surge. A recommended value is given in the table at right.
1 nF/2 kV
1 nF/2 kV
CY1
3. The output filtering capacitor (C3) is a low ESR electrolytic capacitor. Care
1 nF/2 kV
1 nF/2 kV
CY2
must be taken in choosing this capacitor not to exceed the capacitive load
10 µF
10 µF
C3
specification for the unit. Voltage derating of capacitors should be 80% or
above.
4. In many applications simply adding input/output capacitors will enhance the input surge protection and reduce
output ripple sufficiently. Typically, the value of the input
capacitor should be 10 µF to 47 µF. The output capacitor
would be 10 µF.
5. Input noise and surge suppression modules are available for
a number of MPD DC/DC power supplies. For a recommendation for the MA600xERU series, please contact the factory.
Typical Board Layout: Single Output With External Filter/Surge Components
Typical Board Layout: Dual Output With External Filter/Surge Components
MicroPower Direct
•
292 Page Street Ste D Stoughton, MA 02072
• TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected]
www.micropowerdirect.com
Mechanical Dimensions
Pin Connections
Pin
2
3
9
11
14
16
22
23
Single Output
-VIN
-VIN
No Pin
No Connection
+VOUT
-VOUT
+VIN
+VIN
Pin
2
3
9
11
14
16
22
23
Dual Output
-VIN
-VIN
Common
-VOUT
+VOUT
Common
+VIN
+VIN
Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.02 (±0.50)
• Pin 1 is marked by a “dot” or indentation on the top of the unit
Packing Tube Dimensions
Notes:
•
•
•
•
Tube length equals 20.866 (530), unit quantity equals 15 pcs.
Tube length equals 8.661 (220), unit quantity equals 6 pcs.
All dimensions are typical in inches (mm)
Tolerance x.xx = ±0.02 (±0.50)
MicroPower Direct
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: [email protected]