MPD I500ERW

I500ERW Series
Ultra-Miniature 5W
Single & Dual Output
DC/DC Converters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Key Features:
Input
• 5W Output Power
Parameter
• 2:1 Input Range
• Miniature Case
Input Voltage Range
• Single & Dual Outputs
• 1,500 VDC Isolation
• >1 MHour MTBF
Input Filter
Reverse Polarity Input Current
• 32 Standard Models
Output
• LOWEST COST!!
Parameter
Output Voltage Accuracy
Output Voltage Balance
Line Regulation
Load Regulation
Ripple (20 MHz) (Note 1)
Noise (20 MHz) (Note 1)
Output Power Protection
Temperature Coefficient
Output Short Circuit
RoHS Compliant
Conditions
Min.
12 VDC Input
9.0
15 VDC Input 12.0
24 VDC Input 18.0
48 VDC input 36.0
LC Filter
Conditions
Min.
Positive
Negative
Dual Output , Balanced Loads
Vin = Min to Max
Iout = 10% to 100%
Typ.
12.0
15.0
24.0
48.0
Typ.
±1.0
±3.0
±0.2
±0.5
30
100
Max.
18.0
24.0
36.0
72.0
Units
1.0
A
Max.
±3.0
±5.0
±1.0
±0.5
±2.0
50
150
Units
120
±0.02
Continuous (Autorecovery)
±0.03
VDC
%
%
%
mV P - P
mV P - P
%
%/ºC
General
Parameter
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Switching Frequency
Conditions
60 Seconds
500 VDC
100 kHz, 1V
Min.
1,500
1,000
Typ.
Max.
Units
VDC
MΩ
pF
kHz
Max.
+85
+125
Units
ºC
ºC
95
%
150
300
Environmental
MicroPower Direct
Parameter
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
292 Page Street
Suite D
Stoughton, MA 02072
USA
Physical
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Reliability Specifications
Case Size (5V 12V & 24V Input Models)
Case Material
Weight
Parameter
MTBF
Conditions
Min.
Typ.
-40
+25
-55
Free Air Convection
RH, Non-condensing
Ambient
1.08 x 1.08 x 0.38 Inches (25.4 x 25.4 x 9.6 mm)
Metal With Non-Conductive Base (UL94-V0)
0.52 Oz (15g)
Conditions
MIL HDBK 217F, 25ºC, Gnd Benign
Min.
1.0
Typ.
Max.
Units
MHours
Conditions
12 VDC Input
15 VDC Input
24 VDC Input
48 VDC Input
1.5 mm From Case For 10 Sec
All Models
Min.
-0.7
-0.7
-0.7
-0.7
Typ.
Max.
20.0
30.0
40.0
80.0
300
450
Units
Absolute Maximum Ratings
Parameter
Input Voltage Surge (1 Sec)
Lead Temperature
Internal Power Dissipation
VDC
ºC
mW
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
Model Selection Guide
Model
Number
I501ERW
I502ERW
I503ERW
I504ERW
I505ERW
I506ERW
I507ERW
I508ERW
I511ERW
I512ERW
I513ERW
I514ERW
I515ERW
I516ERW
I517ERW
I518ERW
I521ERW
I522ERW
I523ERW
I524ERW
I525ERW
I526ERW
I527ERW
I528ERW
I531ERW
I532ERW
I533ERW
I534ERW
I535ERW
I536ERW
I537ERW
I538ERW
Input
Output
Efficiency
Voltage (VDC)
Current (mA)
Voltage Current
Current
(%, Typ)
Nominal
Range
Full-Load No-Load (VDC) (mA, Max) (mA, Min)
12
9.0 - 18.0
556
25
5.0
1,000
100
75
12
9.0 - 18.0
541
25
9.0
556
56
77
12
9.0 - 18.0
527
25
12.0
420
42
79
12
9.0 - 18.0
514
25
15.0
333
34
81
12
9.0 - 18.0
556
25
±5.0
±500
±50
75
12
9.0 - 18.0
541
25
±9.0
±278
±28
77
12
9.0 - 18.0
527
25
±12.0
±210
±21
79
12
9.0 - 18.0
514
25
±15.0
±166
±17
81
15
12.0 - 24.0
450
20
5.0
1,000
100
74
15
12.0 - 24.0
427
20
9.0
556
56
78
15
12.0 - 24.0
417
20
12.0
420
42
80
15
12.0 - 24.0
412
20
15.0
333
34
81
15
12.0 - 24.0
444
20
±5.0
±500
±50
75
15
12.0 - 24.0
427
20
±9.0
±278
±28
78
15
12.0 - 24.0
416
20
±12.0
±210
±21
82
15
12.0 - 24.0
406
20
±15.0
±166
±17
85
24
18.0 - 36.0
278
12.5
5.0
1,000
100
75
24
18.0 - 36.0
267
12.5
9.0
556
56
78
24
18.0 - 36.0
254
12.5
12.0
420
42
80
24
18.0 - 36.0
245
12.5
15.0
333
34
81
24
18.0 - 36.0
278
12.5
±5.0
±500
±50
75
24
18.0 - 36.0
267
12.5
±9.0
±278
±28
78
24
18.0 - 36.0
254
12.5
±12.0
±210
±21
82
24
18.0 - 36.0
245
12.5
±15.0
±166
±17
85
48
36.0 - 72.0
134
6.25
5.0
1,000
100
78
48
36.0 - 72.0
129
6.25
9.0
556
56
81
48
36.0 - 72.0
124
6.25
12.0
420
42
84
48
36.0 - 72.0
123
6.25
15.0
333
34
85
48
36.0 - 72.0
133
6.25
±5.0
±500
±50
78
48
36.0 - 72.0
128
6.25
±9.0
±278
±28
81
48
36.0 - 72.0
124
6.25
±12.0
±210
±21
84
48
36.0 - 72.0
122
6.25
±15.0
±166
±17
85
Other input/output combinations are available
(i.e. 24 VDC). Contact the factory for details at:
[email protected]
Fuse Rating
Slow-Blow
(mA)
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
700
700
700
700
700
700
700
700
700
700
700
700
700
700
700
700
350
350
350
350
350
350
350
350
Derating Curve
Notes:
1. When measuring output ripple, it is recommended that an external ceramic capacitor (approx
approx 1 µF to 10 µF) be placed from the +Vout pin to the -Vout pin for single output units
and from each output to common for dual output units.
2. These units should not be operated with a load under 10% of full load. Operation at no-load
may cause damage to the unit.
3. These converters are specified for operation without external components. However, in some
applications the addition of input/ouput capacitors will enhance stability and reduce output
ripple. Recommended capacitor values are:
Vin
Input
Capacitor
Vout
Output
Capacitor
12 VDC
15 VDC
24 VDC
48 VDC
100 µF
100 µF
10 µF
10 µF
5 VDC
9 VDC
12 VDC
15 VDC
100 µF
100 µF
100 µF
100 µF
Mechanical Dimensions
For applications requiring very low output noise levels, a simple LC filter should be
effective.
4. Dual output units may be connected to provide a 10V, 18V, 24V or 30 VDC output.
To do this, connect the load across the positive (+Vout) and negative (-Vout) outputs and float the output common.
5. It is recommended that a fuse be used on the input of a power supply for
protection. See the Model Selection table above for the correct rating.
Pin Connections
Pin
Single
Dual
Pin
Single
Dual
1
2
3
+Vin
-Vin
+Vout
+Vin
-Vin
+Vout
4
5
No Pin
-Vout
Common
-Vout
Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.01 (±0.25)
• Pin 1 is marked by a “dot” on the top of the unit
MicroPower Direct
www.micropowerdirect.com
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: [email protected]