D200EI Datasheet - Micropower Direct

D200EI Series
Low Cost, 2W SIP
High Isolation
DC/DC Converters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Key Features:
Input
• 2W Output Power
• Miniature SIP Case
• UL Approved (File E245422)
• Single & Dual Outputs
• 3,000 VDC Isolation
• >3.5 MHour MTBF
• 24 Standard Models
• LOWEST COST!!
Parameter
Conditions
Input Voltage Range
Input Filter
Reverse Polarity Input Current
Min.
Typ.
5 VDC Input
4.5
5.0
12 VDC Input 10.8
12.0
24 VDC Input 21.6
24.0
Internal Capacitor
Max.
5.5
13.2
26.4
Units
0.3
A
Max.
±3.0
±1.0
Units
%
%
%
150
mV P - P
%
%/ºC
VDC
Output
Parameter
Output Voltage Accuracy
Output Voltage Balance
Line Regulation
Load Regulation, See Note 1
Ripple & Noise (20 MHz)
Output Power Protection
Temperature Coefficient
Output Short Circuit
Conditions
Min.
Typ.
±1.0
Dual Output , Balanced Loads
±0.1
For Vin Change of 1%
±1.2
See Model Selection Guide
See Note 3
100
120
±0.02
Momentary (1.0 Sec.)
±0.03
General
Parameter
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Switching Frequency
Conditions
60 Seconds
500 VDC
100 kHz, 1V
Min.
3,000
1,000
Typ.
Max.
Units
VDC
M
pF
kHz
Max.
+85
+125
Units
ºC
ºC
95
%
60
75
Environmental
Parameter
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Physical
Case Size (5V 12V & 24V Input Models)
Case Material
Weight
Conditions
Min.
Typ.
-40
+25
-55
Free Air Convection
RH, Non-condensing
Ambient
0.77 x 0.28 x 0.40 Inches (19.6 x 7.0 x 10.2 mm)
Non-Conductive Black Plastic (UL94-V0)
0.07 Oz (2.1g)
Reliability Specifications
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
Parameter
MTBF
Safety Standards
Safety Approvals
Conditions
Min.
Typ.
MIL HDBK 217F, 25ºC, Gnd Benign
3.5
UL 1950, EN 60950, IEC 60950
UL, cUL; File No. E245422
Max.
Units
MHours
Max.
9.0
18.0
30.0
300
450
Units
Absolute Maximum Ratings
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Parameter
Conditions
Input Voltage Surge (1 Sec)
Lead Temperature
Internal Power Dissipation
5 VDC Input
12 VDC Input
24 VDC Input
1.5 mm From Case For 10 Sec
All Models
Min.
-0.7
-0.7
-0.7
Typ.
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com
VDC
ºC
mW
www.micropowerdirect.com
Model Selection Guide
Input
Model
Number
Voltage (VDC)
Current (mA)
Voltage
Nominal
Range
Full-Load No-Load (VDC)
5
4.5 - 5.5
500
30
5.0
5
4.5 - 5.5
494
30
9.0
5
4.5 - 5.5
488
30
12.0
5
4.5 - 5.5
476
30
15.0
5
4.5 - 5.5
488
30
±5.0
5
4.5 - 5.5
482
30
±9.0
5
4.5 - 5.5
470
30
±12.0
5
4.5 - 5.5
470
30
±15.0
12
10.8 - 13.2
208
15
5.0
12
10.8 - 13.2
201
15
9.0
12
10.8 - 13.2
198
15
12.0
12
10.8 - 13.2
196
15
15.0
12
10.8 - 13.2
201
15
±5.0
12
10.8 - 13.2
198
15
±9.0
12
10.8 - 13.2
194
15
±12.0
12
10.8 - 13.2
194
15
±15.0
24
21.6 - 26.4
103
8
5.0
24
21.6 - 26.4
99
8
9.0
24
21.6 - 26.4
98
8
12.0
24
21.6 - 26.4
97
8
15.0
24
21.6 - 26.4
99
8
±5.0
24
21.6 - 26.4
98
8
±9.0
24
21.6 - 26.4
96
8
±12.0
24
21.6 - 26.4
96
8
±15.0
D201EI
D202EI
D203EI
D204EI
D205EI
D206EI
D207EI
D208EI
D211EI
D212EI
D213EI
D214EI
D215EI
D216EI
D217EI
D218EI
D221EI
D222EI
D223EI
D224EI
D225EI
D226EI
D227EI
D228EI
Notes:
1. Output load regulation is specified for a load change of 10% to 100%.
2. These units should not be operated with a load under 10% of full load. Operation
at no-load may cause damage to the unit.
3. These converters will operate without external components. However, when
measuring output ripple, it is recommended that an external ceramic capacitor
be placed from the +Vout pin to the -Vout pin for single output units and from
each output to common for dual output units. An input capacitor will enhance
stability over temperature and input line variations. Recommended capacitor
values are given in the table below. For applications requiring very low output
noise levels, a simple LC filter should be effective.
Input
Vout
Capacitor
5 VDC
4.7 µF
5 VDC
12 VDC 2.2 µF
9 VDC
24 VDC 1.0 µF 12 VDC
15 VDC
Vin
Output
Current
Current
Load
Regulation
(mA, Max)
(mA, Min)
(%, Max)
40.0
23.0
17.0
14.0
±20.0
±12.0
±9.0
±7.0
40.0
23.0
17.0
14.0
±20.0
±12.0
±9.0
±7.0
40.0
23.0
17.0
14.0
±20.0
±12.0
±9.0
±7.0
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
400.0
222.0
167.0
133.0
±200.0
±111.0
±83.0
±67.0
400.0
222.0
167.0
133.0
±200.0
±111.0
±83.0
±67.0
400.0
222.0
167.0
133.0
±200.0
±111.0
±83.0
±67.0
Rating
Efficiency Fuse
Slow-Blow
(%, Typ)
(mA)
80
81
82
84
82
83
85
85
80
83
84
85
83
84
86
86
81
84
85
86
84
85
87
87
1,000
1,000
1,000
1,000
1,000
1,000
1,000
1,000
500
500
500
500
500
500
500
500
200
200
200
200
200
200
200
200
g Curve
Derating
Output Capacitor
Single
Dual
10.0 µF 4.7 µF
4.7 µF 2.2 µF
2.2 µF 1.0 µF
1.0 µF 0.47 µF
4. Dual output units may be connected to provide a 10V, 18V, 24V or 30 VDC output.
To do this, connect the load across the positive (+Vout) and negative (-Vout)
outputs and float the output common
5. It is recommended that a fuse be used on the input of a power supply for
protection. See the Model Selection table above for the correct rating.
Mechanical Dimensions
Pin Connections
Pin
Single
Dual
Pin
Single
Dual
1
2
5
+Vin
-Vin
-Vout
+Vin
-Vin
-Vout
6
7
No Pin
+Vout
Common
+Vout
Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.01 (±0.25)
• Pin 1 is marked by a “dot” or indentation on the side of the unit
MicroPower Direct
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: [email protected]