D200EI Series Low Cost, 2W SIP High Isolation DC/DC Converters Electrical Specifications Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice. Key Features: Input • 2W Output Power • Miniature SIP Case • UL Approved (File E245422) • Single & Dual Outputs • 3,000 VDC Isolation • >3.5 MHour MTBF • 24 Standard Models • LOWEST COST!! Parameter Conditions Input Voltage Range Input Filter Reverse Polarity Input Current Min. Typ. 5 VDC Input 4.5 5.0 12 VDC Input 10.8 12.0 24 VDC Input 21.6 24.0 Internal Capacitor Max. 5.5 13.2 26.4 Units 0.3 A Max. ±3.0 ±1.0 Units % % % 150 mV P - P % %/ºC VDC Output Parameter Output Voltage Accuracy Output Voltage Balance Line Regulation Load Regulation, See Note 1 Ripple & Noise (20 MHz) Output Power Protection Temperature Coefficient Output Short Circuit Conditions Min. Typ. ±1.0 Dual Output , Balanced Loads ±0.1 For Vin Change of 1% ±1.2 See Model Selection Guide See Note 3 100 120 ±0.02 Momentary (1.0 Sec.) ±0.03 General Parameter Isolation Voltage Isolation Resistance Isolation Capacitance Switching Frequency Conditions 60 Seconds 500 VDC 100 kHz, 1V Min. 3,000 1,000 Typ. Max. Units VDC M pF kHz Max. +85 +125 Units ºC ºC 95 % 60 75 Environmental Parameter Operating Temperature Range Storage Temperature Range Cooling Humidity Physical Case Size (5V 12V & 24V Input Models) Case Material Weight Conditions Min. Typ. -40 +25 -55 Free Air Convection RH, Non-condensing Ambient 0.77 x 0.28 x 0.40 Inches (19.6 x 7.0 x 10.2 mm) Non-Conductive Black Plastic (UL94-V0) 0.07 Oz (2.1g) Reliability Specifications MicroPower Direct 292 Page Street Suite D Stoughton, MA 02072 USA Parameter MTBF Safety Standards Safety Approvals Conditions Min. Typ. MIL HDBK 217F, 25ºC, Gnd Benign 3.5 UL 1950, EN 60950, IEC 60950 UL, cUL; File No. E245422 Max. Units MHours Max. 9.0 18.0 30.0 300 450 Units Absolute Maximum Ratings T: (781) 344-8226 F: (781) 344-8481 E: [email protected] W: www.micropowerdirect.com Parameter Conditions Input Voltage Surge (1 Sec) Lead Temperature Internal Power Dissipation 5 VDC Input 12 VDC Input 24 VDC Input 1.5 mm From Case For 10 Sec All Models Min. -0.7 -0.7 -0.7 Typ. Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings. www.micropowerdirect.com VDC ºC mW www.micropowerdirect.com Model Selection Guide Input Model Number Voltage (VDC) Current (mA) Voltage Nominal Range Full-Load No-Load (VDC) 5 4.5 - 5.5 500 30 5.0 5 4.5 - 5.5 494 30 9.0 5 4.5 - 5.5 488 30 12.0 5 4.5 - 5.5 476 30 15.0 5 4.5 - 5.5 488 30 ±5.0 5 4.5 - 5.5 482 30 ±9.0 5 4.5 - 5.5 470 30 ±12.0 5 4.5 - 5.5 470 30 ±15.0 12 10.8 - 13.2 208 15 5.0 12 10.8 - 13.2 201 15 9.0 12 10.8 - 13.2 198 15 12.0 12 10.8 - 13.2 196 15 15.0 12 10.8 - 13.2 201 15 ±5.0 12 10.8 - 13.2 198 15 ±9.0 12 10.8 - 13.2 194 15 ±12.0 12 10.8 - 13.2 194 15 ±15.0 24 21.6 - 26.4 103 8 5.0 24 21.6 - 26.4 99 8 9.0 24 21.6 - 26.4 98 8 12.0 24 21.6 - 26.4 97 8 15.0 24 21.6 - 26.4 99 8 ±5.0 24 21.6 - 26.4 98 8 ±9.0 24 21.6 - 26.4 96 8 ±12.0 24 21.6 - 26.4 96 8 ±15.0 D201EI D202EI D203EI D204EI D205EI D206EI D207EI D208EI D211EI D212EI D213EI D214EI D215EI D216EI D217EI D218EI D221EI D222EI D223EI D224EI D225EI D226EI D227EI D228EI Notes: 1. Output load regulation is specified for a load change of 10% to 100%. 2. These units should not be operated with a load under 10% of full load. Operation at no-load may cause damage to the unit. 3. These converters will operate without external components. However, when measuring output ripple, it is recommended that an external ceramic capacitor be placed from the +Vout pin to the -Vout pin for single output units and from each output to common for dual output units. An input capacitor will enhance stability over temperature and input line variations. Recommended capacitor values are given in the table below. For applications requiring very low output noise levels, a simple LC filter should be effective. Input Vout Capacitor 5 VDC 4.7 µF 5 VDC 12 VDC 2.2 µF 9 VDC 24 VDC 1.0 µF 12 VDC 15 VDC Vin Output Current Current Load Regulation (mA, Max) (mA, Min) (%, Max) 40.0 23.0 17.0 14.0 ±20.0 ±12.0 ±9.0 ±7.0 40.0 23.0 17.0 14.0 ±20.0 ±12.0 ±9.0 ±7.0 40.0 23.0 17.0 14.0 ±20.0 ±12.0 ±9.0 ±7.0 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 400.0 222.0 167.0 133.0 ±200.0 ±111.0 ±83.0 ±67.0 400.0 222.0 167.0 133.0 ±200.0 ±111.0 ±83.0 ±67.0 400.0 222.0 167.0 133.0 ±200.0 ±111.0 ±83.0 ±67.0 Rating Efficiency Fuse Slow-Blow (%, Typ) (mA) 80 81 82 84 82 83 85 85 80 83 84 85 83 84 86 86 81 84 85 86 84 85 87 87 1,000 1,000 1,000 1,000 1,000 1,000 1,000 1,000 500 500 500 500 500 500 500 500 200 200 200 200 200 200 200 200 g Curve Derating Output Capacitor Single Dual 10.0 µF 4.7 µF 4.7 µF 2.2 µF 2.2 µF 1.0 µF 1.0 µF 0.47 µF 4. Dual output units may be connected to provide a 10V, 18V, 24V or 30 VDC output. To do this, connect the load across the positive (+Vout) and negative (-Vout) outputs and float the output common 5. It is recommended that a fuse be used on the input of a power supply for protection. See the Model Selection table above for the correct rating. Mechanical Dimensions Pin Connections Pin Single Dual Pin Single Dual 1 2 5 +Vin -Vin -Vout +Vin -Vin -Vout 6 7 No Pin +Vout Common +Vout Notes: • All dimensions are typical in inches (mm) • Tolerance x.xx = ±0.01 (±0.25) • Pin 1 is marked by a “dot” or indentation on the side of the unit MicroPower Direct We Power Your Success - For Less! 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected]